CRITICAL APPRAISAL OF VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES

被引:61
|
作者
Bignardi, Mario [2 ]
Cozzi, Luca [1 ]
Fogliata, Antonella
Lattuada, Paola [2 ]
Mancosu, Pietro [2 ]
Navarria, Piera [2 ]
Urso, Gaetano [2 ]
Vigorito, Sabrina [2 ]
Scorsetti, Marta [2 ]
机构
[1] Oncol Inst So Switzerland, Dept Radiat Oncol, Med Phys Unit, CH-6504 Bellinzona, Switzerland
[2] Ist Clin Humanitas, Rozzano, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 75卷 / 05期
关键词
RapidArc; Stereotactic body radiation therapy; IMRT; Volumetric modulated are therapy; MONTE-CARLO CALCULATIONS; CLINICAL IMPLEMENTATION; CONFORMAL RADIOTHERAPY; INTENSITY MODULATION; DOSE CALCULATION; LIVER; IMRT; CANCER; TUMORS; LUNG;
D O I
10.1016/j.ijrobp.2009.05.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose(min) >95%, Dose(max) <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V-15Gy <35% for both kidneys, V-36Gy <1% for duodenum, V36Gy <3% for stomach and small bowel, V-15Gy <(total liver volume - 700 cm(3)) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V-95% = 90.2% +/- 5.2% for RA compared with 82.5% +/- 9.6% and 84.5% +/- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +/- 211 for RA, 2583 +/- 699 for IM, and 1554 +/- 153 for CRT. Effective treatment time resulted as follows: 3.7 +/- 0.4 min for RA, 10.6 +/- 1.2 min for IM, and 6.3 +/- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM. (C) 2009 Elsevier Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [1] Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy
    Diot, Quentin
    Kavanagh, Brian
    Timmerman, Robert
    Miften, Moyed
    MEDICAL PHYSICS, 2012, 39 (01) : 237 - 245
  • [2] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [3] Fractionated Stereotactic Radiation Therapy Using Volumetric Modulated Arc Therapy in Patients with Solitary Brain Metastases
    Zhou, Chong
    Xia, Youyou
    Huang, Pei
    Guan, Luan
    Shen, Xiaoming
    Hao, Dawei
    Chen, Meng
    Ren, Hongrong
    Lian, Lian
    Yin, Haitao
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [4] Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy
    Bokrantz, Rasmus
    Wedenberg, Minna
    Sandwall, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 103 - 109
  • [5] A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
    Li, Xinyi
    Wu, Jackie
    Palta, Manisha
    Zhang, You
    Sheng, Yang
    Zhang, Jiahan
    Wang, Chunhao
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [6] Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results
    Scorsetti, Marta
    Bignardi, Mario
    Alongi, Filippo
    Fogliata, Antonella
    Mancosu, Pietro
    Navarria, Piera
    Castiglioni, Simona
    Pentimalli, Sara
    Tozzi, Angelo
    Cozzi, Luca
    ACTA ONCOLOGICA, 2011, 50 (04) : 528 - 538
  • [7] Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates
    Yamashita, Hideomi
    Haga, Akihiro
    Takahashi, Wataru
    Takenaka, Ryousuke
    Imae, Toshikazu
    Takenaka, Shigeharu
    Nakagawa, Keiichi
    RADIATION ONCOLOGY, 2014, 9 : 243
  • [8] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [9] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Wang, Po-Ming
    Hsu, Wei-Chung
    Chung, Na-Na
    Chang, Feng-Ling
    Jang, Chin-Jyh
    Fogliata, Antonella
    Scorsetti, Marta
    Cozzi, Luca
    RADIATION ONCOLOGY, 2014, 9
  • [10] Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy
    Vieillevigne, Laure
    Bessieres, Sandra
    Ouali, Monia
    Lanaspeze, Christel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1405 - 1414