On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample

被引:17
作者
Zhang, Xiuli
Martens, Dieter
Kraemer, Petra M.
Kettrup, Antonius A.
Liang, Xinmiao
机构
[1] LUFA Speyer, D-67346 Speyer, Germany
[2] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
[3] GSF, Inst Ecol Chem, Natl Res Ctr Environm & Hlth, D-85764 Neuherberg, Germany
[4] Tech Univ Munich, Lehrstuhl Okol Chem & Umweltanalyt, D-85350 Freising Weihenstephan, Germany
关键词
immunoaffinity column; diuron; on-line; LC-MS-MS; matrix effect; wastewater;
D O I
10.1016/j.chroma.2006.08.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy (similar to 90% of recovery) and precision (< 6% of relative standard deviation) at 50 ng/L concentration were also obtained. Due to the ability of the sol-gel immunoaffinity column to eliminate matrix effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 45 条
[21]  
*ISO, 1990, 84661 ISO INT ORG ST
[22]   Affinity monoliths for ultrafast immunoextraction [J].
Jiang, T ;
Mallik, R ;
Hage, DS .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2362-2372
[23]   Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry [J].
Kampioti, AA ;
da Cunha, ACB ;
de Alda, ML ;
Barceló, D .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) :1815-1825
[24]   VALIDATION OF A MONOCLONAL IMMUNOASSAY FOR DIURON IN GROUNDWATER [J].
KARU, AE ;
SCHMIDT, DJ ;
RICHMAN, SJ ;
COOPER, C ;
TRAN, D ;
HSU, J .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (02) :310-315
[25]   SYNTHESIS OF HAPTENS AND DERIVATION OF MONOCLONAL-ANTIBODIES FOR IMMUNOASSAY OF THE PHENYLUREA HERBICIDE DIURON [J].
KARU, AE ;
GOODROW, MH ;
SCHMIDT, DJ ;
HAMMOCK, BD ;
BIGELOW, MW .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (02) :301-309
[26]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[27]   Development of a portable immunoextraction-reversed-phase liquid chromatography system for field studies of herbicide residues [J].
Nelson, MA ;
Gates, A ;
Dodlinger, M ;
Hage, DS .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :805-813
[28]   Selective determination of a group of organic compounds in complex sample matrixes by LC/MIMS with on line immunoaffinity extraction [J].
Ouyang, S ;
Xu, Y ;
Chen, YH .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :931-935
[29]  
PANTIRU M, 2004, THESIS TU MUNICH MUN
[30]   PREPARATION AND EVALUATION OF IMMUNOSORBENTS FOR SELECTIVE TRACE ENRICHMENT OF PHENYLUREA AND TRIAZINE HERBICIDES IN ENVIRONMENTAL WATERS [J].
PICHON, V ;
CHEN, L ;
HENNION, MC ;
DANIEL, R ;
MARTEL, A ;
LEGOFFIC, F ;
ABIAN, J ;
BARCELO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2451-2460