Conebeam CT of the Head and Neck, Part 2: Clinical Applications

被引:217
作者
Miracle, A. C. [1 ]
Mukherji, S. K. [1 ,2 ,3 ]
机构
[1] Univ Michigan Hlth Syst, Univ Hosp, Dept Radiol, Ann Arbor, MI USA
[2] Univ Michigan Hlth Syst, Univ Hosp, Dept Otolaryngol, Ann Arbor, MI USA
[3] Univ Michigan Hlth Syst, Univ Hosp, Dept Radiat Oncol, Ann Arbor, MI USA
关键词
BEAM-COMPUTED-TOMOGRAPHY; DIGITAL VOLUME TOMOGRAPHY; ENDOSCOPIC SINUS SURGERY; IN-VITRO; TEMPOROMANDIBULAR-JOINT; MAXILLOFACIAL RADIOLOGY; AMERICAN ACADEMY; ROTATIONAL TOMOGRAPHY; PERIODONTAL BONE; POSITION PAPER;
D O I
10.3174/ajnr.A1654
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Conebeam x-ray CT (CBCT) is being increasingly used for point-of-service head and neck and dentomaxillofacial imaging. This technique provides relatively high isotropic spatial resolution of osseous structures with a reduced radiation dose compared with conventional CT scans. In this second installment in a 2-part review, the clinical applications in the dentomaxillofacial and head and neck regions will be explored, with particular emphasis on diagnostic imaging of the sinuses, temporal bone, and craniofaciai structures. Several controversies surrounding the emergence of CBCT technology will also be addressed.
引用
收藏
页码:1285 / 1292
页数:8
相关论文
共 88 条
[1]  
Aboudara C A, 2003, Orthod Craniofac Res, V6 Suppl 1, P173, DOI 10.1034/j.1600-0544.2003.253.x
[2]  
Alspaugh J, 2007, P 49 ANN M AM ASS PH
[3]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[4]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[5]   Imaging procedures in cochlear implant patients - Evaluation of different radiological techniques [J].
Aschendorff, A ;
Kubalek, R ;
Hochmuth, A ;
Bink, A ;
Kurtz, C ;
Lohnstein, P ;
Klenzner, T ;
Laszig, R .
ACTA OTO-LARYNGOLOGICA, 2004, 124 :46-49
[6]   Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery [J].
Bachar, G. ;
Siewerdsen, J. H. ;
Daly, M. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2007, 34 (12) :4664-4677
[7]   Increase of accuracy in intraoperative navigation through high-resolution flat-panel volume computed tomography: Experimental comparison with multislice computed tomography-based navigation [J].
Bartling, Soenke H. ;
Leinung, Martin ;
Graute, Johannes ;
Rodt, Thomas ;
Dullin, Christian ;
Becker, Hartmut ;
Lenarz, Thomas ;
Stover, Timo ;
Majdani, Omid .
OTOLOGY & NEUROTOLOGY, 2007, 28 (01) :129-134
[8]   Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures [J].
Batra, Pete S. ;
Kanowitz, Seth J. ;
Citardi, Martin J. .
AMERICAN JOURNAL OF RHINOLOGY, 2008, 22 (05) :511-515
[9]   Imaging of the temporomandibular joint - A position paper of the American Academy of Oral and Maxillofacial Radiology [J].
Brooks, SL ;
Brand, JW ;
Gibbs, SJ ;
Hollender, L ;
Lurie, AG ;
Omnell, KA ;
Westesson, PL ;
White, SC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 83 (05) :609-618
[10]   American Academy of Oral and Maxillofacial Radiology executive opinion statement on performing and interpreting diagnostic cone beam computed tomography [J].
Carter, Laurie ;
Geist, James ;
Scarfe, William C. ;
Angelopoulos, Christos ;
Nair, Madhu K. ;
Odont, Lic ;
Hildebolt, Charles F. ;
Tyndall, Donald ;
Shrout, Michael .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (04) :561-562