Ultrafiltration Process in Disinfection and Advanced Treatment of Tertiary Treated Wastewater

被引:19
作者
Bray, Rafal Tytus [1 ]
Jankowska, Katarzyna [1 ]
Kulbat, Eliza [1 ]
Luczkiewicz, Aneta [1 ]
Sokolowska, Aleksandra [1 ]
机构
[1] Gdansk Univ Technol, Fac Civil & Environm Engn, Dept Water & Wastewater Technol, 11-12 Narutowicza St, PL-80233 Gdansk, Poland
关键词
membranes; indicator bacteria; microscopic methods; SYBR GREEN-I; ANTIMICROBIAL RESISTANCE; ANTIBIOTIC-RESISTANCE; MICROBIAL DIVERSITY; HUMAN ADENOVIRUSES; ESCHERICHIA-COLI; ORGANIC NITROGEN; FECAL INDICATORS; UV DISINFECTION; MARINE VIRUSES;
D O I
10.3390/membranes11030221
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The paper presents the results of research on the use of ultrafiltration, using membranes of 200 and 400 kDa separation, for disinfection of municipal treated wastewater. The research was conducted on a fractional technical scale using real municipal treated wastewater from two large wastewater treatment plants treating most of the wastewater over the one-million polycentric Gdansk agglomeration (1.2 million inhabitants). UF 200 kDa and UF 400 kDa processes enabled further improvement of the physical and chemical parameters of treated wastewater. Total phosphorus (to below 0.2 mg/L-UF 200 kDa, 0.13 mg/L-UF 400 kDa) and turbid substances (to below 0.2 mg/L, both membranes) were removed in the highest degree. COD was reduced efficiently (to below 25.6 mgO(2)/L-UF 200 kDa, 26.8 mgO(2)/L-UF 400 kDa), while total nitrogen was removed to a small extent (to 7.12 mg/L-UF 200 kDa and 5.7 mg/L-UF 400 kDa. Based on the reduction of indicator bacteria; fecal coliforms including E. coli (FC) and fecal enterococci (FE) it was found that the ultrafiltration is an effective method of disinfection. Not much indicator bacterial were observed in the permeate after processes (UF 200 kDa; FC-5 CFU/L; FE-1 CFU/L and UF 400 kDa; FC-70 CFU/L; FE-10 CFU/L. However, microscopic analysis of prokaryotic cells and virus particles showed their presence after the application of both membrane types; TCN 3.0 x 10(2) cells/mL-UF 200 kDa, 5.0 x 10(3) cells/mL-UF 400 kDa, VP 1.0 x 10(5)/mL. The presence of potentially pathogenic, highly infectious virus particles means that ultrafiltration cannot be considered a sufficient disinfection method for treated wastewater diverted for reuse or discharged from high load wastewater treatment plants to recreational areas. For full microbiological safety it would be advisable to apply an additional disinfection method (e.g., ozonation).
引用
收藏
页数:18
相关论文
共 86 条
[41]   SARS-CoV-2 in wastewater: State of the knowledge and research needs [J].
Kitajima, Masaaki ;
Ahmed, Warish ;
Bibby, Kyle ;
Carducci, Annalaura ;
Gerba, Charles P. ;
Hamilton, Kerry A. ;
Haramoto, Eiji ;
Rose, Joan B. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 739
[42]   Peracetic acid (PAA) disinfection of primary, secondary and tertiary treated municipal wastewaters [J].
Koivunen, J ;
Heinonen-Tanski, H .
WATER RESEARCH, 2005, 39 (18) :4445-4453
[43]   Inactivation of enteric microorganisms with chemical disinfectants, UV irradiation and combined chemical/UV treatments [J].
Koivunen, J ;
Heinonen-Tanski, H .
WATER RESEARCH, 2005, 39 (08) :1519-1526
[44]   Elimination of enteric bacteria in biological-chemical wastewater treatment and tertiary filtration units [J].
Koivunen, J ;
Siitonen, A ;
Heinonen-Tanski, H .
WATER RESEARCH, 2003, 37 (03) :690-698
[45]   Environmental characteristics of a tundra river systemin Svalbard. Part 1: Bacterial abundance, community structure and nutrient levels [J].
Kosek, Klaudia ;
Luczkiewicz, Aneta ;
Koziol, Krystyna ;
Jankowska, Katarzyna ;
Ruman, Marek ;
Polkowska, Zaneta .
SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 653 :1571-1584
[46]   The interaction between bacterial abundance and selected pollutants concentration levels in an arctic catchment (southwest Spitsbergen, Svalbard) [J].
Kosek, Klaudia ;
Kozak, Katarzyna ;
Koziol, Krystyna ;
Jankowska, Katarzyna ;
Chmiel, Stanislaw ;
Polkowska, Zaneta .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 622 :913-923
[47]   Antibiotic resistance and prevalence of class 1 and 2 integrons in Escherichia coli isolated from two wastewater treatment plants, and their receiving waters (Gulf of Gdansk, Baltic Sea, Poland) [J].
Kotlarska, Ewa ;
Luczkiewicz, Aneta ;
Pisowacka, Marta ;
Burzynski, Artur .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (03) :2018-2030
[48]  
Kowal P., 2015, DEZYNFEKCJA SCIEKOW, V1st ed.
[49]   Comparison of methods to assess the integrity and separation efficiency of ultrafiltration membranes in wastewater reclamation processes [J].
Krahnstover, Therese ;
Hochstrat, Rita ;
Wintgens, Thomas .
JOURNAL OF WATER PROCESS ENGINEERING, 2019, 30
[50]   Occurrence of Disinfection Byproducts in United States Wastewater Treatment Plant Effluents [J].
Krasner, Stuart W. ;
Westerhoff, Paul ;
Chen, Baiyang ;
Rittmann, Bruce E. ;
Amy, Gary .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (21) :8320-8325