Design characteristics of perforated pooled circular stepped cascade (PPCSC) aeration system

被引:18
作者
Roy, Subha M. [1 ]
Moulick, Sanjib [2 ]
Mukherjee, Chanchal Kumar [1 ]
机构
[1] Indian Inst Technol Kharagpur, Agr & Food Engn Dept, Kharagpur 721302, W Bengal, India
[2] Kalinga Inst Ind Technol, Sch Civil Engn, Bhubaneswar 751024, Odisha, India
关键词
aeration; aeration efficiency; aquaculture; perforated pooled circular stepped cascade aerator; PERFORMANCE; PREDICTION; RATES;
D O I
10.2166/ws.2020.078
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present study, an improvised design over circular stepped cascade (CSC) and pooled circular stepped cascade (PCSC) aerator, named the perforated pooled circular stepped cascade (PPCSC) aerator, has been conceptualized and tested for its suitability as an aerator for small intensive aquaculture ponds. Based on dimensional analysis, dimensionless geometric parameters - ratio of width of consecutive steps (W-i/Wi+1) and ratio of perforation diameter to bottom-most radius (d/R-b) and dimensionless dynamic parameters - Froude (Fr) and Reynolds (Re) number were proposed. Initially, aeration experiments were conducted to optimize the geometric parameters, keeping the dynamic parameters constant. Keeping the optimized values of W-i/Wi+1 = 1.05 and d/R-b = 0.0027 as constants, aeration experiments were further conducted at different discharges (Q) and different bottommost radius (R-b) to study the characteristics of oxygen transfer and power consumption of PPCSC aerator at different dynamic conditions. Based on the optimized results, four prototype PPCSC aerators with R-b = 0.75 m, 0.90 m, 1.05 m and 1.20 m were fabricated for their aeration performances. The results showed that the standard aeration efficiency (SAE) values of the prototype PPCSC aerators based on brake power ranged between 3.36 and 4.98 kg O-2/kWh, with the average being 4.45 +/- 0.741 kg O-2/kWh. This shows that the SAE of the PPCSC aerator is many more folds higher than that of the other available cascade aerators, viz., PCSC (SAE: 2.873 +/- 0.342 kg O-2/kWh) and CSC (2.470 +/- 0.256 kg O-2/kWh) aerators. The study clearly indicates that this PPCSC aerator may very well be used as pre-aeration or post-aeration units in water or wastewater treatment plants and small-scale intensive aquacultural ponds, replacing the other existing aerators.
引用
收藏
页码:1692 / 1705
页数:14
相关论文
共 29 条
[1]  
ASCE, 1993, Measurement of oxygen transfer in clean water, V2nd ed
[2]  
ASCE, 2007, STAND MEAS OX TRANSF, DOI 10.1061/9780784408483
[3]   Aeration efficiency with nappe flow over stepped cascades [J].
Baylar, A. ;
Bagatur, T. ;
Emiroglu, M. E. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MANAGEMENT, 2007, 160 (01) :43-50
[4]   Numerical analysis of hydraulic jumps using OpenFOAM [J].
Bayon-Barrachina, Arnau ;
Amparo Lopez-Jimenez, Petra .
JOURNAL OF HYDROINFORMATICS, 2015, 17 (04) :662-678
[5]  
Boyd C. E., 2009, P WORLD AQ SOC M, P25
[6]   Pond water aeration systems [J].
Boyd, CE .
AQUACULTURAL ENGINEERING, 1998, 18 (01) :9-40
[7]  
[陈晓曦 Chen Xiaoxi], 2019, [心理科学进展, Advances in Psychological Science], V27, P1
[8]   Passive aeration of wastewater treated by an anaerobic process-A design approach [J].
El-Zahaby, Ayman M. ;
El-Gendy, Ahmed S. .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2016, 4 (04) :4565-4573
[9]  
ELLIOTT JW, 1969, PROG FISH CULT, V31, P67, DOI 10.1577/1548-8640(1969)31[67:TOROCS]2.0.CO
[10]  
2