Multiple ruptures of the extensor tendons after volar fixation for distal radius fracture: a case report

被引:5
作者
Caruso, Giancarlo [1 ]
Vitali, Andrea [1 ]
del Prete, Ferdinando [2 ]
机构
[1] Palagi Hosp IOT, Hlth Firm Hand, Florence, Italy
[2] SGD Hosp, Dept Orthopaed & Traumatol, Florence, Italy
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷
关键词
fractures of distal radius; ruptures of tendons; open reduction internal fixation (ORIF); secondary displacement; tendon transfer; PLATE FIXATION; INTERNAL-FIXATION; COMPLICATIONS; OUTCOMES; DORSAL;
D O I
10.1016/S0020-1383(15)30040-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
A 62-year-old woman was admitted to our hospital after a bicycle accident with a displaced left (non-dominant) distal radius fracture. After closed reduction a long cast was applied. Due to loss of reduction, twenty-four days later open reduction internal fixation with locking compression plate (LCP) was performed. The patient returned to her normal activities but nineteen months after surgery showed functional impairment of the left thumb for Extensor Pollicis Longus (EPL) injury for which she necessitated transposition surgery. Twenty-six months after ORIF, functional deficit of the extension of the third and fourth left finger was noted secondary to injury of extensor tendons. Ultrasound and CT scan showed protrusion of the angular stability screws in LCP plate that caused a progressive wear resulting in rupture of the extensor tendons. Another tendon transposition surgery was performed with dorsal approach while the plate was removed utilising the original volar incision. Reconstruction of distal radius fractures with volar plating, requires accurate plate application with precise measurement of the length of the screws in order to prevent dorsal protrusion and thus avoiding tendon injuries. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S23 / S27
页数:5
相关论文
共 21 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Functional outcomes after open reduction and internal fixation for treatment of displaced distal radius fractures in patients over 60 years of age [J].
Beharrie, AW ;
Beredjiklian, PK ;
Bozentka, DJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :680-686
[4]   Complications of Volar Plate Fixation for Managing Distal Radius Fractures [J].
Berglund, Lisa M. ;
Messer, Terry M. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (06) :369-377
[5]  
Caruso G, 2010, RIV CHIRURGIA MANO, V47, P22
[6]   DELAYED RUPTURE OF EXTENSOR DIGITORUM COMMUNIS TENDON FOLLOWING VOLAR PLATING OF DISTAL RADIUS FRACTURE [J].
Hattori, Yasunori ;
Doi, Kazuteru ;
Sakamoto, Soutetsu ;
Yukata, Kiminori .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2008, 13 (03) :183-185
[7]   A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures [J].
Margaliot, Z ;
Haase, SC ;
Kotsis, SV ;
Kim, HM ;
Chung, KC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06) :1185-1199
[8]   Assessment of complications of distal radius fractures and development of a complication checklist [J].
McKay, SD ;
MacDermid, JC ;
Roth, JH ;
Richards, RS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05) :916-922
[9]   Essential radiographic evaluation for distal radius fractures [J].
Medoff, RJ .
HAND CLINICS, 2005, 21 (03) :279-+
[10]   Plate fixation of osteoporotic fractures of the distal radius [J].
Mudgal, Chaitanya S. ;
Jupiter, Jesse B. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (08) :S106-S115