Separation and determination of phenolic compounds by capillary electrophoresis with chemiluminescence detection

被引:65
作者
Tsukagoshi, K [1 ]
Kameda, T [1 ]
Yamamoto, M [1 ]
Nakajima, R [1 ]
机构
[1] Doshisha Univ, Fac Engn, Dept Chem Engn & Mat Sci, Kyoto 6100321, Japan
关键词
chemiluminescence detection; detection; electrophoresis; buffer composition; chlorophenols; nitrophenols; phenols;
D O I
10.1016/S0021-9673(02)01408-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Phenolic compounds were analyzed by means of capillary electrophoresis with chemiluminescence detection. Peroxyoxalate chemiluminescence reagent was used together with dansyl chloride as a labeling reagent. The reagent concentrations, the labeling procedures, and the performance of chemilurninescence detection cells were examined for sensitive detection of phenolic compounds. Six kinds of phenolic compounds (phenol, 2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, and 2,4,6-trichlorophenol) were determined over a range of three orders of magnitude with detection limits of the order of 10(-7) M; their detection limits were ca. 10 times as low as those obtained by an ordinary fluorescence detector. A running buffer solution containing sodium dodecylsulfate and acetonitrile provided satisfactory results in the separation of 15 kinds of phenolic compounds. The combination of capillary electrophoresis with chemiluminescence detection and column concentration procedure supported the possibility that the present system could be applied to real samples such as surface and reused waters. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 19 条
[1]   RETRACTED: Synergistic activation of estrogen receptor with combinations of environmental chemicals (Retracted Article) [J].
Arnold, SF ;
Klotz, DM ;
Collins, BM ;
Vonier, PM ;
Guillette, LJ ;
McLachlan, JA .
SCIENCE, 1996, 272 (5267) :1489-1492
[2]   Determination of bisphenol-A in reusable polycarbonate food-contact plastics and migration to food-simulating liquids [J].
Biles, JE ;
McNeal, TP ;
Begley, TH ;
Hollifield, HC .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (09) :3541-3544
[3]   CHEMI-LUMINESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BIOMEDICAL SAMPLES [J].
DEJONG, GJ ;
KWAKMAN, PJM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 492 :319-343
[4]  
DERUITER C, 1988, J CHROMATOGR, V436, P426
[5]   Critical assessment of electrolyte systems for the capillary electrophoresis analysis of phenolic compounds in herbal extracts [J].
Fonseca, FN ;
Kato, MJ ;
Oliveira, L ;
Neto, NP ;
Tavares, MFM .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (06) :227-235
[6]   Determination of bisphenol A in water by micro liquid-liquid extraction followed by silylation and gas chromatography mass spectrometry analysis [J].
González-Casado, A ;
Navas, N ;
del Olmo, M ;
Vílchez, JL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1998, 36 (11) :565-569
[7]  
HALVAX JJ, 1995, J PHARM BIOMED ANAL, V10, P335
[8]   Compact detection cell using optical fiber for sensitization and simplification of capillary electrophoresis-chemiluminescence detection [J].
Hashimoto, M ;
Tsukagoshi, K ;
Nakajima, R ;
Kondo, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :191-202
[9]  
HIELMAN B, 1996, CHEM ENG NEWS, V74, P29
[10]  
IMAI K, 1985, TRENDS ANAL CHEM, V4, P17