Quantitative determination of azithromycin in human plasma by liquid chromatography-mass spectrometry and its application in a bioequivalence study

被引:48
作者
Chen, Ben-Mei
Liang, Yi-Zeng [1 ]
Chen, Xiang
Liu, Shao-Gang
Deng, Fu-Liang
Zhou, Ping
机构
[1] Cent S Univ, Res Ctr Modernizat Chinese Med, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
[2] Cent S Univ, Analyt Testing Ctr, Sch Xiangya Med, Changsha 410078, Hunan, Peoples R China
[3] Cent S Univ, Dept Urol, Xiangya Hosp, Changsha 410008, Hunan, Peoples R China
关键词
azithromycin; LC-MS; electrospray ionization; bioequivalence;
D O I
10.1016/j.jpba.2006.05.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, rapid liquid chromatographic-electrospray ionization mass spectrometric method for determination of azithromycin in human plasma was developed and validated. Azithromycin in plasma (0.2 mL) was extracted with methyl tert-butyl ether-hexane (50:50, v/v), organic phase was transferred to another clear 1.5 mL Eppendorf tube and evaporated to dryness at 40 degrees C and dissolved in mobile phase, samples were separated using a Thermo Hypersil HyPURITY C 18 reversed-phase column (150 mm x 2.1 mm i.d., 5 mu m), together with a mobile phase containing of 20 mM ammonium acetate (pH 5.2)-acetonitrile-methanol (50:40: 10, v/v/v) and was isocratically eluted at a flow rate of 0.2 mL/mm. Azithromycin and its internal standard, clarithromycin, were measured by electrospray ion source in positive selective ion monitoring mode. The method demonstrated that good linearity ranged from 2 to 1000 ng/mL with r = 0.9977. The limit of quantification for azithromycin in plasma was 2 ng/mL with good accuracy and precision. The higher mean extraction recovery, say 81.2% and 75.5% for azithromycin and internal standard (IS), respectively, was obtained in this work. The intra-day and inter-day precision ranged from 4.8% to 8.6% and 6.4% to 10.7% (R.S.D.), respectively. The established method has been successfully applied to bioequivalence study of 2 azithromycin formulations for 24 healthy volunteers. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:480 / 487
页数:8
相关论文
共 30 条
[21]  
NI MY, 1999, ACTA SHANDONG MED U, V37, P254
[22]   Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of azithromycin in human plasma [J].
Nirogi, RVS ;
Kandikere, VN ;
Shukla, M ;
Mudigonda, K ;
Maurya, S ;
Boosi, R ;
Yerramilli, A .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :1-8
[23]   EQUIVALENCE OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY AND A BIOASSAY OF AZITHROMYCIN IN HUMAN SERUM SAMPLES [J].
RIEDEL, KD ;
WILDFEUER, A ;
LAUFEN, H ;
ZIMMERMANN, T .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 576 (02) :358-362
[24]   Steady-state plasma and bronchopulmonary concentrations of intravenous levofloxacin and azithromycin in healthy adults [J].
Rodvold, KA ;
Danziger, LH ;
Gotfried, MH .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2003, 47 (08) :2450-2457
[25]   PHARMACOKINETICS OF AZITHROMYCIN IN RATS AND DOGS [J].
SHEPARD, RM ;
FALKNER, FC .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1990, 25 :49-60
[26]   Determination of erythromycin, clarithromycin, roxithromycin, and azithromycin in plasma by high-performance liquid chromatography with amperometric detection [J].
Taninaka, C ;
Ohtani, H ;
Hanada, E ;
Kotaki, H ;
Sato, H ;
Iga, T .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :405-411
[27]   Quantitative determination of the macrolide antibiotics erythromycin, roxithromycin, azithromycin and clarithromycin in human serum by high-performance liquid chromatography using pre-column derivatization with 9-fluorenylmethyloxycarbonyl chloride and fluorescence detection [J].
Toraño, JS ;
Guchelaar, HJ .
JOURNAL OF CHROMATOGRAPHY B, 1998, 720 (1-2) :89-97
[28]   Quantitative determination of azithromycin in plasma, blood and isolated neutrophils by liquid chromatography using pre-column derivatization with 9-fluorenylmethyloxycarbonyl-chloride and fluorescence detection [J].
Wilms, E ;
Trumpie, H ;
Veenendaal, W ;
Touw, D .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (01) :37-42
[29]   Studies on electrochemical oxidation of azithromycin and its interaction with bovine serum albumin [J].
Wu, YH ;
Ji, XB ;
Hu, SS .
BIOELECTROCHEMISTRY, 2004, 64 (01) :91-97
[30]   A new HPLC method for azithromycin quantitation [J].
Zubata, P ;
Ceresole, R ;
Rosasco, MA ;
Pizzorno, MT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (05) :833-836