Post-Fault Tolerant of Symmetrical Six-Phase Induction Machine Under Open Circuit Fault With Single and Two Isolated Neutral Points Using Graphical User Interface

被引:3
作者
Mule, Gabriel Jamit Anak [1 ]
Munim, Wan Noraishah Wan Abdul [1 ,2 ]
Tousizadeh, Mahdi [2 ]
Abidin, Ahmad Farid [1 ]
机构
[1] Univ Technol MARA UiTM, Fac Elect Engn, Shah Alam 40450, Selangor, Malaysia
[2] Univ Malaya, UMPEDAC, Kuala Lumpur 59990, Malaysia
来源
ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING: FROM THEORY TO APPLICATIONS, SERIES 2 | 2019年 / 2173卷
关键词
Symmetrical six-phase; fault-tolerance; maximum torque; minimum loss; derating factor; GUI; OPERATION;
D O I
10.1063/1.5133931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a post-fault tolerant analysis of symmetrical six-phase induction machines under one to three open circuit faults considering maximum torque and minimum loss for different neutral connections namely single isolated and two isolated neutrals. Post-fault performance is performed based on derating factor, minimum stator copper loss and minimum peak current. The rationality of the theoretical post-fault current limits are justified by the simulation result. In addition, a user-friendly graphical user interface tool has been developed for teaching and learning purposes in machine and drive course using Matlab.
引用
收藏
页数:14
相关论文
共 17 条
[1]   Postfault Operation of a Nine-Phase Six-Terminal Induction Machine Under Single Open-Line Fault [J].
Abdel-Khalik, Ayman Samy ;
Hamad, Mostafa S. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (02) :1084-1096
[2]  
Andreatos A. S., 2018, P 6 WSEAS INT C ENG, P208
[3]   Propulsion Drive Models for Full Electric Marine Propulsion Systems [J].
Apsley, Judith M. ;
Gonzalez-Villasenor, Aurelio ;
Barnes, Mike ;
Smith, Alexander C. ;
Williamson, Steve ;
Schuddebeurs, Jeroen D. ;
Norman, Patrick J. ;
Booth, Campbell D. ;
Burt, Graeme M. ;
McDonald, J. R. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (02) :676-684
[4]  
Burzanowska H., 2007, 2007 EUR C POW EL AP
[5]  
Che Hang Seng, 2014, IEEE T POWER ELECTR, V29, P5406
[6]   Model Predictive Control of Six-Phase Induction Motor Drives Using Virtual Voltage Vectors [J].
Gonzalez-Prieto, Ignacio ;
Duran, Mario J. ;
Aciego, Juan J. ;
Martin, Cristina ;
Barrero, Federico .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) :27-37
[7]   Impact of Postfault Flux Adaptation on Six-Phase Induction Motor Drives With Parallel Converters [J].
Gonzalez-Prieto, Ignacio ;
Duran, Mario J. ;
Barrero, Federico ;
Bermudez, Mario ;
Guzman, Hugo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :515-528
[8]   Fault-Tolerant Operation of Six-Phase Energy Conversion Systems With Parallel Machine-Side Converters [J].
Gonzalez-Prieto, Ignacio ;
Duran, Mario J. ;
Che, H. S. ;
Levi, Emil ;
Bermudez, Mario ;
Barrero, Federico .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) :3068-3079
[9]   A MATLAB/GUI BASED FAULT SIMULATION TOOL FOR POWER SYSTEM EDUCATION [J].
Koc, Savas ;
Aydogmus, Zafer .
MATHEMATICAL & COMPUTATIONAL APPLICATIONS, 2009, 14 (03) :207-217
[10]   Multiphase Machines and Drives-Revisited [J].
Levi, Emil ;
Barrero, Federico ;
Duran, Mario J. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (01) :429-432