Thermal shunt for quick cool-down of two-stage closed-cycle refrigerator

被引:0
作者
Uhlig, K [1 ]
机构
[1] Bayer Akad Wissensch, Walther Meissner Inst Tieftemp Forsch, D-85748 Garching, Germany
关键词
Gifford-McMahon; thermal shunt;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
An efficient and easy-to-build gas circuit is described which acts as a thermal shunt between the two stages of a Gifford-McMahon cooler (GMC) during the cool-down period or an experiment. With this circuit the high cooling power of the first stage is used to cool objects with a large heat capacity attached to the second stage like a superconducting magnet or, as in our case, a dilution refrigerator (DR) with a vacuum can. The circuit is driven by a small fraction Or the helium gas of the Gifford-McMahon refrigerator and precools the DR from room temperature to a temperature of 50 K. The shunt Circuit reduces the cool-down time by a factor of two in our cryostat. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:67 / 69
页数:3
相关论文
共 4 条
[1]   Development of a thermal switch for faster cool-down by two-stage cryocooler [J].
Chang, HM ;
Kim, HJ .
CRYOGENICS, 2000, 40 (12) :769-777
[2]  
GUY KW, 1979, EXPT TECHNIQUES LOW
[3]  
Prenger FC, 1996, ADV CRYOG ENG, P147
[4]   He-3/He-4 dilution refrigerator precooled by Gifford-McMahon refrigerator [J].
Uhlig, K ;
Hehn, W .
CRYOGENICS, 1997, 37 (05) :279-282