Detection and identification of multiple IGBT open-circuit faults in PWM inverters for AC machine drives

被引:56
作者
Bae, Cheol-Ju [1 ]
Lee, Dong-Choon [2 ]
Thanh Hai Nguyen [3 ]
机构
[1] Hyundai Rotem Co, R&D Ctr, Elect Equipment Dev Team, Uiwang Si, South Korea
[2] Yeungnam Univ, Dept Elect Engn, Gyongsan, South Korea
[3] Khalifa Univ Sci & Technol, Dept Elect & Comp Engn, Abu Dhabi, U Arab Emirates
基金
新加坡国家研究基金会;
关键词
invertors; PWM invertors; insulated gate bipolar transistors; fault diagnosis; identification; multiple IGBT open-circuit faults; PWM inverters; AC machine drives; online detection; insulated-gate bipolar transistor open-circuit faults; three-phase pulse-width modulation inverters; machine phase currents; switch open-circuit faults; actual phase currents; leg open-circuit conditions; line-to-line currents; single open-circuit IGBT; corresponding phase current; fault detection time; OPEN-SWITCH FAULTS; VOLTAGE-SOURCE INVERTERS; MOTOR-DRIVES; DIAGNOSIS;
D O I
10.1049/iet-pel.2018.5188
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study proposes a new scheme for online detection and identification of single and multiple insulated-gate bipolar transistor (IGBT) open-circuit faults in three-phase pulse-width modulation (PWM) inverters of AC machine drives, which is based on Park's vector of machine phase currents. First, the switch open-circuit faults are detected by monitoring dwell times of the vector of the actual phase currents expressed in the stationary reference frame in each sector, where the normalisation of the current to its reference value is utilised, by which the immunity to the false alarms in transient conditions is improved significantly. Then, the IGBT open-circuit faults are identified, where leg open-circuit conditions are in the first place determined based on the average values of the normalised line-to-line currents. Next, the single open-circuit IGBT is located from the polarity of the corresponding phase current. By the proposed diagnosis method, the fault detection time is at the longest about 52.3 and 54% of a fundamental period in the simulation and experimental tests, respectively, and the 27 possible cases of IGBT open-circuit faults combined for all IGBTs in the inverter can be identified. In addition, this algorithm can be implemented without any additional hardware and computational burden.
引用
收藏
页码:923 / 931
页数:9
相关论文
共 34 条
[21]  
Kim DE, 2009, J POWER ELECTRON, V9, P377
[22]   Fault Detection of a Proposed Three-Level Inverter Based on a Weighted Kernel Principal Component Analysis [J].
Lin, Mao ;
Li, Ying-Hui ;
Qu, Liang ;
Wu, Chen ;
Yuan, Guo-Qiang .
JOURNAL OF POWER ELECTRONICS, 2016, 16 (01) :182-189
[23]   A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters [J].
Lu, Bin ;
Sharma, Santosh K. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (05) :1770-1777
[24]   A Series Stacked IGBT Switch With Robustness Against Short-Circuit Fault for Pulsed Power Applications [J].
Mohsenzade, Sadegh ;
Zarghany, Mostafa ;
Kaboli, Shahriyar .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) :3779-3790
[25]  
Mutoh N, 2003, IEEE IND APPLIC SOC, P459
[26]   Fault detection of open-switch damage in voltage-fed PWM motor drive systems [J].
Ribeiro, RLD ;
Jacobina, CB ;
da Silva, ERC ;
Lima, AMN .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (02) :587-593
[27]  
Rothenhagen K., 2005, P EUR C POW EL APPL, P1
[28]   FPGA Based Robust Open Transistor Fault Diagnosis and Fault Tolerant Sliding Mode Control of Five-Phase PM Motor Drives [J].
Salehifar, Mehdi ;
Salehi Arashloo, Ramin ;
Moreno Eguilaz, Manuel ;
Sala, Vicent .
JOURNAL OF POWER ELECTRONICS, 2015, 15 (01) :131-145
[29]   Adaptive high bandwidth current control for induction machines [J].
Telford, D ;
Dunnigan, MW ;
Williams, BW .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (02) :527-538
[30]  
Trabelsi M, 2012, 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1717, DOI 10.1109/ICElMach.2012.6350112