Application of syringe to syringe dispersive micro-solid phase extraction using a magnetic layered double hydroxide for the determination of cadmium(II) and lead(II) ions in food and water samples

被引:26
作者
Arghavani-Beydokhti, Somayeh [1 ]
Rajabi, Maryam [1 ]
Asghari, Alireza [1 ]
机构
[1] Semnan Univ, Dept Chem, Semnan 35195363, Iran
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; ACTIVATED CARBON; METAL-IONS; ENVIRONMENTAL-SAMPLES; EXPERIMENTAL-DESIGN; NANOPARTICLES; OPTIMIZATION; REMOVAL; MICROEXTRACTION; COPRECIPITATION;
D O I
10.1039/c7ay01857f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research work, for the first time, a new mode of dispersive solid-phase extraction named syringe to syringe magnetic dispersive micro-solid phase extraction is introduced as an efficient, simple, rapid, and eco-friendly sample extraction method. A nickel-aluminum layered double hydroxide coated on magnetic nanoparticles (Fe3O4@Ni-Al-CO3-LDH), as an efficient nanosorbent, was synthesized and successfully applied for the concurrent extraction of trace amounts of Cd2+ and Pb2+ ions in food and water samples prior to their determination using a microsampling-flame atomic absorption spectrometry technique. After extraction and magnetic separation, the elution step was easily performed through dissolving the magnetic layered double hydroxide (LDH) containing the target analytes in an acidic solution. Also the use of a magnetic LDH overcomes the difficulty of phase separation that decreases the extraction time. The optimum conditions efficiently evaluated via the response surface methodology (RSM) were pH 7.0, 13.7 mg of the nanosorbent, 16 extraction cycles, 125 mu L of 3.8 mol L-1 trifluoroacetic acid, and an ultrasonic time of 75 s. According to the optimum conditions obtained in above, good linear ranges (0.75-35 ng mL(-1) for Cd2+ ions and 4.0-370 ng mL(-1) for Pb2+ ions) with coefficient of determination (R-2) values higher than 0.995 were obtained. The limits of detection were found to be 0.25 and 1.0 ng mL(-1) for Cd2+ and Pb2+, respectively. The preconcentration factor for the target analytes was 80 in a 10 mL sample solution. The obtained results indicated the high quality of the developed procedure for the much-needed quantification of the aforementioned metal ions in food and water samples.
引用
收藏
页码:1305 / 1314
页数:10
相关论文
共 35 条
[1]   Solid phase extraction of metal ions in environmental samples on 1-(2-pyridylazo)-2-naphthol impregnated activated carbon cloth [J].
Alothman, Zeid A. ;
Yilmaz, Erkan ;
Habila, Mohamed ;
Soylak, Mustafa .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2015, 112 :74-79
[2]   Ligandless temperature-controlled ionic liquid-phase microextraction of lead(II) ion prior to its determination by FAAS [J].
Alothman, Zeid A. ;
Yilmaz, Erkan ;
Habila, Mohamed ;
Shabaka, Azza ;
Soylak, Mustafa .
MICROCHIMICA ACTA, 2013, 180 (7-8) :669-674
[3]   Coupling of two centrifugeless ultrasound-assisted dispersive solid/liquid phase microextractions as a highly selective, clean, and efficient method for determination of ultra-trace amounts of non-steroidal anti-inflammatory drugs in complicated matrices [J].
Arghavani-Beydokhti, Somayeh ;
Rajabi, Maryam ;
Asghari, Alireza .
ANALYTICA CHIMICA ACTA, 2018, 997 :67-79
[4]   Combination of magnetic dispersive micro solid-phase extraction and supramolecular solvent-based microextraction followed by high-performance liquid chromatography for determination of trace amounts of cholesterol-lowering drugs in complicated matrices [J].
Arghavani-Beydokhti, Somayeh ;
Rajabi, Maryam ;
Asghari, Alireza .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (18) :4395-4407
[5]   Centrifuge-free dispersive liquid-liquid microextraction based on the salting-out effect followed by high performance liquid chromatography for simple and sensitive determination of polycyclic aromatic hydrocarbons in water samples [J].
Arghavani-Beydokhti, Somayeh ;
Rajabi, Maryam ;
Bazregar, Mohammad ;
Asghari, Alireza .
ANALYTICAL METHODS, 2017, 9 (11) :1732-1740
[6]   Application of a tandem air-agitated liquid-liquid microextraction technique based on solidification of floating organic droplets as an efficient extraction method for determination of cholesterol-lowering drugs in complicated matrices [J].
Arghavani-Beydokhti, Somayeh ;
Asghari, Alireza ;
Bazregar, Mohammad ;
Rajabi, Maryam .
RSC ADVANCES, 2016, 6 (96) :93582-93589
[7]   Magnetic nanoparticle based dispersive micro-solid-phase extraction for the determination of malachite green in water samples: optimized experimental design [J].
Asfaram, Arash ;
Ghaedi, Mehrorang ;
Goudarzi, Alireza ;
Soylak, Mustafa ;
Langroodi, Sanaz Mehdizadeh .
NEW JOURNAL OF CHEMISTRY, 2015, 39 (12) :9813-9823
[8]   Determination of carboxylic acids in non-alcoholic beer samples by an ultrasonic-assisted dispersive micro-solid phase extraction based on Ni/Cu-Al layered double hydroxide nanocomposites followed by gas chromatography [J].
Babaee, Shirin ;
Daneshfar, Ali ;
Khezeli, Tahere .
ULTRASONICS SONOCHEMISTRY, 2017, 34 :847-855
[9]   Immobilization of albumin on aminosilane modified superparamagnetic magnetite nanoparticles and its characterization [J].
Can, Keziban ;
Ozmen, Mustafa ;
Ersoz, Mustafa .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 71 (01) :154-159
[10]   Optimization of dispersive micro solid-phase extraction for the rapid determination of benzophenone-type ultraviolet absorbers in aqueous samples [J].
Chung, Wu-Hsun ;
Tzing, Shin-Hwa ;
Ding, Wang-Hsien .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1411 :17-22