Feasibility Study of a Wearable Exoskeleton for Children: Is the Gait Altered by Adding Masses on Lower Limbs?

被引:38
|
作者
Rossi, Stefano [1 ,2 ]
Colazza, Alessandra [2 ]
Petrarca, Maurizio [2 ]
Castelli, Enrico [2 ]
Cappa, Paolo [2 ,3 ]
Krebs, Hermano Igo [4 ,5 ,6 ]
机构
[1] Univ Tuscia, DEIM Dept Econ & Management Ind Engn, Viterbo, Italy
[2] Bambino Gesu Pediat Hosp, MARLab Movement Anal & Robot Lab, Neurosci & Neurorehabil Dept, Rome, Italy
[3] Univ Roma La Sapienza, Dept Mech & Aerosp Engn, I-00185 Rome, Italy
[4] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[5] Univ Maryland, Sch Med, Dept Neurol, Baltimore, MD 21201 USA
[6] Univ Maryland, Sch Med, Div Rehabil Med, Baltimore, MD 21201 USA
来源
PLOS ONE | 2013年 / 8卷 / 09期
关键词
CEREBRAL-PALSY; REHABILITATION; EPIDEMIOLOGY; WALKING; ROBOT; IMPAIRMENTS; ORTHOSES; DESIGN; SYSTEM;
D O I
10.1371/journal.pone.0073139
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five "with added mass" conditions. We found significant differences among "natural gait" and "with added masses" conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here.
引用
收藏
页数:9
相关论文
共 49 条
  • [1] Control Architecture of a 10 DOF Lower Limbs Exoskeleton for Gait Rehabilitation
    Koceska, Natasa
    Koceski, Saso
    Durante, Francesco
    Zobel, Pierluigi Beomonte
    Raparelli, Terenziano
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2013, 10
  • [2] A Survey of Wearable Lower Extremity Neurorehabilitation Exoskeleton: Sensing, Gait Dynamics, and Human-Robot Collaboration
    Li, Jie
    Gu, Xiao
    Qiu, Sen
    Zhou, Xu
    Cangelosi, Angelo
    Loo, Chu Kiong
    Liu, Xiaofeng
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2024, 54 (06): : 3675 - 3693
  • [3] Design and Experimental Evaluation of Wearable Lower Extremity Exoskeleton with Gait Self-adaptivity
    Wang, Wenkang
    Zhang, Liancun
    Cai, Kangjian
    Wang, Zhiheng
    Zhang, Bainan
    Huang, Qiang
    ROBOTICA, 2019, 37 (12) : 2035 - 2055
  • [4] A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy
    Zachary F. Lerner
    Taryn A. Harvey
    Jennifer L. Lawson
    Annals of Biomedical Engineering, 2019, 47 : 1345 - 1356
  • [5] Gait training early after stroke with a new exoskeleton - the hybrid assistive limb: a study of safety and feasibility
    Nilsson, Anneli
    Vreede, Katarina Skough
    Haglund, Vera
    Kawamoto, Hiroaki
    Sankai, Yoshiyuki
    Borg, Jorgen
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [6] Wearable Lower-Limb Exoskeleton for Children With Cerebral Palsy: A Systematic Review of Mechanical Design, Actuation Type, Control Strategy, and Clinical Evaluation
    Sarajchi, Mohammadhadi
    Al-Hares, Mohamad Kenan
    Sirlantzis, Konstantinos
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 (29) : 2695 - 2720
  • [7] A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy
    Lerner, Zachary F.
    Harvey, Taryn A.
    Lawson, Jennifer L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (06) : 1345 - 1356
  • [8] Efficacy of dance-based paradigms, wearable sensors, and auditory feedback for gait retraining in children: A feasibility study
    Pitale, Jaswandi Tushar
    Bolte, John H.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2020, 24 (02) : 57 - 62
  • [9] Clinical study on the safety and feasibility of AiWalker-K for lower limbs exercise rehabilitation in children with cerebral palsy
    Zhang, Yi
    Hui, Zhichong
    Qi, Weihang
    Zhang, Jiamei
    Wang, Mingmei
    Zhu, Dengna
    PLOS ONE, 2024, 19 (05):
  • [10] A new lower limb portable exoskeleton for gait assistance in neurological patients: a proof of concept study
    Puyuelo-Quintana, G.
    Cano-de-la-Cuerda, R.
    Plaza-Flores, A.
    Garces-Castellote, E.
    Sanz-Merodio, D.
    Goni-Arana, A.
    Marin-Ojea, J.
    Garcia-Armada, E.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)