Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode

被引:116
作者
Sulak, MT
Gökdogan, Ö
Gülce, A
Gülce, H
机构
[1] Selcuk Univ, Dept Chem Engn, TR-42031 Konya, Turkey
[2] Gebze Inst Technol, Dept Environm Engn, Gabze, Turkey
关键词
polyvinylferrocene; gold deposition; glucose; electrochemical biosensor;
D O I
10.1016/j.bios.2005.08.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinyl ferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method forthe immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer. PVF. and the cold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential. the thickness of the polymeric film. the amount of the immobilized enzyme, pH. the amount of the deposited An, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1719 / 1726
页数:8
相关论文
共 42 条
[1]   Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers [J].
Alonso, B ;
Armada, PG ;
Losada, J ;
Cuadrado, I ;
González, B ;
Casado, CM .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (12) :1617-1625
[2]  
Armada MPG, 2003, SENSOR ACTUAT B-CHEM, V88, P190, DOI 10.1016/S0925-4005(02)00326-X
[3]  
Celej MS, 1998, ELECTROANAL, V10, P771, DOI 10.1002/(SICI)1521-4109(199809)10:11<771::AID-ELAN771>3.0.CO
[4]  
2-P
[5]   Sol-gel-derived titanium oxide/copolymer composite based glucose biosensor [J].
Chen, X ;
Dong, SJ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (08) :999-1004
[6]   A new step to the mechanism of the enhancement effect of gold nanoparticles on glucose oxidase [J].
Chen, XY ;
Li, JR ;
Li, XC ;
Jiang, L .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1998, 245 (02) :352-355
[7]   Amperometric glucose sensors based on ferrocene-containing B-polyethylenimine and immobilized glucose oxidase [J].
Chuang, CL ;
Wang, YJ ;
Lan, HL .
ANALYTICA CHIMICA ACTA, 1997, 353 (01) :37-44
[8]   Polyvinylferrocenium modified Pt electrode for anaerobic glucose monitoring [J].
Gülce, A ;
Gülce, H .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2005, 62 (01) :81-92
[9]   ELECTROCHEMICAL RESPONSE OF POLY(VINYLFERROCENIUM)-COATED PT ELECTRODES TO SOME ANIONS IN AQUEOUS-MEDIA [J].
GULCE, H ;
OZYORUK, H ;
YILDIZ, A .
ELECTROANALYSIS, 1995, 7 (02) :178-183
[10]   AMPEROMETRIC ENZYME ELECTRODE FOR AEROBIC GLUCOSE MONITORING PREPARED BY GLUCOSE-OXIDASE IMMOBILIZED IN POLY(VINYLFERROCENIUM) [J].
GULCE, H ;
OZYORUK, H ;
CELEBI, SS ;
YILDIZ, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2) :63-70