Rapid ungated myocardial perfusion cardiovascular magnetic resonance: preliminary diagnostic accuracy

被引:20
|
作者
Harrison, Alexis [1 ,2 ]
Adluru, Ganesh [2 ,3 ]
Damal, Kavitha [2 ]
Shaaban, Akram M. [5 ]
Wilson, Brent [1 ,2 ]
Kim, Daniel [2 ,3 ,5 ]
McGann, Chris [1 ,2 ]
Marrouche, Nassir F. [1 ,2 ]
DiBella, Edward V. R. [2 ,3 ,4 ,5 ]
机构
[1] Univ Utah, Div Cardiol, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Internal Med, CARMA, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84112 USA
[4] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[5] Univ Utah, Dept Radiol, Salt Lake City, UT 84112 USA
关键词
Gating; ECG; Ungated cardiac MR; Myocardial perfusion imaging; Cardiac perfusion; Contrast-enhanced MRI; CORONARY-ARTERY-DISEASE; EMISSION COMPUTED-TOMOGRAPHY; HEART-DISEASE; MR-IMPACT; MULTICENTER; ACQUISITION; MULTIVENDOR; PERFORMANCE; STRESS;
D O I
10.1186/1532-429X-15-26
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial perfusion cardiovascular magnetic resonance (CMR) is a well-established method for detection of ischemic heart disease. However, ECG gating problems can result in image degradation and non-diagnostic scans, particularly in patients with arrhythmias. Methods: A turboFLASH saturation recovery pulse sequence was used without any ECG triggering. One saturation pulse followed by 4-5 slices of undersampled radial k-space images was acquired rapidly, on the order of 40-50 msec per image. The acquisition of the set of 4-5 slices was continuously repeated approximately 4 times per second. An iterative constrained reconstruction method was used to reconstruct the ungated images. The ungated perfusion images were post-processed into three different sets of images (ungated, self-gated to near systole, and self-gated to near diastole). To test the ungated approach and compare the different processing methods, 8 patients scheduled for coronary angiography underwent stress and rest perfusion imaging with the ungated acquisition. Six patients had a history of atrial fibrillation (AF). Three blinded readers assessed image quality and presence/absence of disease. Results: All 8 subjects successfully completed the perfusion CMR protocol and 7/8 underwent coronary angiography. Three patients were in atrial fibrillation during CMR. Overall, the CMR images were of high quality as assessed by the three readers. There was little difference in image quality between patients in AF compared to those in sinus rhythm (3.6 +/- 0.7 vs. 3.3 +/- 0.5). Stress/rest perfusion imaging showed normal perfusion in 4 patients, fixed perfusion defects in 2 patients, and reversible perfusion defects in 2 patients, corresponding with angiographic results. Pooled results from the independent readers gave a sensitivity of 0.92 (CI 0.65-0.99) and specificity of 0.92 (CI 0.65-0.99) for the detection of coronary artery disease using ungated perfusion imaging. The same sensitivity, and a specificity of 1 (CI 0.76-1), was achieved when the images were self-gated after acquisition into near systole or near diastole. Conclusions: Ungated radial dynamic perfusion CMR can give high quality imaging in patients in sinus rhythm and during atrial fibrillation. In this small cohort, high diagnostic accuracy was possible with this rapid perfusion imaging sequence. An ungated approach simplifies the acquisition and could expand the role of perfusion CMR to include patients with arrhythmia and those with gating problems.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] ACCURACY OF RAPID CARDIOVASCULAR MAGNETIC RESONANCE ASSESSMENT OF LEFT VENTRICULAR FUNCTION
    Mabudian, Leila
    D'Agostino, Ralph B.
    Jordan, Jennifer H.
    Martin, Madalyn B.
    Fleshman, Julia A.
    Crotts, Teresa
    Ladd, Amy
    Weaver, Kathryn E.
    Lesser, Glenn J.
    Hackney, Mary Helen
    Hundley, W. Gregory
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1215 - 1215
  • [32] Accelerated, high spatial resolution cardiovascular magnetic resonance myocardial perfusion imaging
    Motwani, Manish
    Lockie, Timothy
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) : 952 - 958
  • [33] Quantitative myocardial perfusion imaging by cardiovascular magnetic resonance and positron emission tomography
    K. Bratis
    I. Mahmoud
    A. Chiribiri
    E. Nagel
    Journal of Nuclear Cardiology, 2013, 20 : 860 - 870
  • [34] Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification
    Peter Kellman
    Michael S. Hansen
    Sonia Nielles-Vallespin
    Jannike Nickander
    Raquel Themudo
    Martin Ugander
    Hui Xue
    Journal of Cardiovascular Magnetic Resonance, 19
  • [35] Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification
    Kellman, Peter
    Hansen, Michael S.
    Nielles-Vallespin, Sonia
    Nickander, Jannike
    Themudo, Raquel
    Ugander, Martin
    Xue, Hui
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [36] Cardiovascular Magnetic Resonance of Myocardial Structure, Function, and Perfusion in Mouse and Rat Models
    Frank Kober
    Monique Bernard
    Thomas Troalen
    Thibaut Capron
    Current Cardiovascular Imaging Reports, 2012, 5 (2) : 109 - 115
  • [37] Accelerated, high spatial resolution cardiovascular magnetic resonance myocardial perfusion imaging
    Manish Motwani
    Timothy Lockie
    John P. Greenwood
    Sven Plein
    Journal of Nuclear Cardiology, 2011, 18 : 952 - 958
  • [38] Direct comparison of myocardial perfusion cardiovascular magnetic resonance sequences with parallel acquisition
    Lyne, Jonathan C.
    Gatehouse, Peter D.
    Assomull, Ravi G.
    Smith, Gillian C.
    Kellman, Peter
    Firmin, David N.
    Pennell, Dudley J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (06) : 1444 - 1451
  • [39] Cardiovascular Magnetic Resonance of Myocardial Structure, Function, and Perfusion in Mouse and Rat Models
    Kober, Frank
    Bernard, Monique
    Troalen, Thomas
    Capron, Thibaut
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2012, 5 (02) : 109 - 115
  • [40] Quantitative myocardial perfusion imaging by cardiovascular magnetic resonance and positron emission tomography
    Bratis, K.
    Mahmoud, I.
    Chiribiri, A.
    Nagel, E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 860 - 870