Ammonia release from heated 'street' cannabis leaf and its potential toxic effects on cannabis users

被引:28
作者
Bloor, Roger N. [1 ]
Wang, Tianshu S. [2 ]
Spanel, Patrik [3 ]
Smith, David [2 ]
机构
[1] Keele Univ, Harplands Hosp, Acad Suite, Acad Psychiat Unit,Sch Med, Stoke On Trent ST4 6TH, Staffs, England
[2] Keele Univ, Sch Med, Inst Sci & Technol Med, Stoke On Trent, Staffs, England
[3] Acad Sci Czech Republ, J Heyrovsky Inst Phys & Chem, Prague, Czech Republic
关键词
ammonia; cannabis; respiratory; SIFT-MS; smoking; toxicity;
D O I
10.1111/j.1360-0443.2008.02281.x
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Aims To use selected ion flow tube mass spectrometry (SIFT-MS) to analyse the molecular species emitted by heated 'street' cannabis plant material, especially targeting ammonia. Materials and methods Samples of 'street' cannabis leaf, held under a UK Home Office licence, were prepared by finely chopping and mixing the material. The samples were then heated in commercially available devices. The air containing the released gaseous compounds was sampled into the SIFT-MS instrument for analysis. Smoke from standard 3% National Institute on Drug Abuse (NIDA) cannabis cigarettes was also analysed. Findings For 'street' cannabis, ammonia was present in the air samples from the devices at levels approaching 200 parts per million (p.p.m.). This is compared with peak levels of 10 p.p.m. using NIDA samples of known provenance and tetrahydrocannabinol content (3%). Several other compounds were present at lower levels, including acetaldehyde, methanol, acetone, acetic acid and uncharacterized terpenes. Conclusions Awareness of the risks of inhaling the smoke directly from burning cannabis has led to the development of a number of alternative methods of delivery, which are claimed to be safer than direct smoking. Ammonia at toxic levels is produced from heating 'street' cannabis in these commercially available devices. Thus, the use of these devices to deliver 'street' cannabis is now open to question and further research is needed to investigate their safety.
引用
收藏
页码:1671 / 1677
页数:7
相关论文
共 28 条
[1]  
AMES FR, 1979, S AFR MED J, V55, P1127
[2]   Quad quantum cascade laser spectrometer with dual gas cells for the simultaneous analysis of mainstream and sidestream cigarette smoke [J].
Baren, RE ;
Parrish, ME ;
Shafer, KH ;
Harward, CN ;
Quan, S ;
Nelson, DD ;
McManus, JB ;
Zahniser, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (14) :3437-3447
[3]  
Baur X, 1997, Pneumologie, V51, P1087
[4]   Applications of selected ion flow tube mass spectrometry, SIFT-MS, in addiction research [J].
Bloor, R ;
Wang, TS ;
Spanel, P ;
Smith, D .
BREATH ANALYSIS: FOR CLINICAL DIAGNOSIS AND ATHERAPEUTIC MONITORING, 2005, :409-420
[5]  
*BRIT LUNG FDN, 2005, SMOK GUN IMP CANN SM
[6]   Bronchial hyperreactivity in patients who inhale heroin mixed with cocaine vaporized on aluminum foil [J].
de los Bueis, AB ;
Vega, AP ;
Ramos, JLS ;
Pérez, JAM ;
García, RA ;
Jiménez, DG ;
de La Llave, EP .
CHEST, 2002, 121 (04) :1223-1230
[7]  
FLURY KE, 1983, MAYO CLIN PROC, V58, P389
[8]  
GHONEIM MT, 1980, PHARMAZIE, V35, P226
[9]  
Gieringer D., 2004, Journal of Cannabis Therapeutics, V4, P7, DOI 10.1300/J175v04n01_02
[10]  
GIERINGER D, 2000, MARIJUANA WATER PIPE