Determination of optimum pixel size and slice thickness for tractography and ulnar nerve diffusion tensor imaging at the cubital tunnel using 3T MRI

被引:6
作者
Park, Sun-Young [1 ]
Koh, Sung Hye [1 ]
Lee, In Jae [1 ]
Lee, Kwanseop [1 ]
Lee, Yul [1 ]
机构
[1] Hallym Univ, Dept Radiol, Sacred Heart Hosp, Gwanpyeong Ro 170 Beon Gil, Anyang Si 14068, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
3T magnetic resonance imaging; diffusion tensor imaging; fractional anisotropy; slice thickness; tractography; ulnar nerve; pixel size; MEDIAN NERVE; NEUROPATHY; NEUROGRAPHY; ANISOTROPY;
D O I
10.1177/0284185120951965
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Small peripheral nerve tractography is challenging because of the trade-off among resolution, image acquisition time, and signal-to-noise ratio. Purpose To optimize pixel size and slice thickness parameters for fiber tractography and diffusion tensor imaging (DTI) of the ulnar nerve at the cubital tunnel using 3T magnetic resonance imaging (MRI). Material and Methods Fifteen healthy volunteers (mean age 30 +/- 6.8 years) were recruited prospectively. Axial T2-weighted and DTI scans were acquired, covering the cubital tunnel, using different pixel sizes and slice thicknesses. Three-dimensional (3D) nerve tractography was evaluated for the median number and length of the reconstructed fiber tracts and visual score from 0 to 5. Two-dimensional (2D) cross-sectional DTI was evaluated for fractional anisotropy (FA) values throughout the length of the ulnar nerve. Results A pixel size of 1.3 mm(2)revealed the highest number of reconstructed nerve fibers compared to that of 1.1 mm(2)(P = 0.048), with a good visual score. A slice thickness of 4 mm had the highest number of reconstructed nerve fibers and visual score compared with other thicknesses (allP < 0.05). In 2D cross-sectional images, the median FA values were in the range of 0.40-0.63 at the proximal, central, and distal portions of the cubital tunnel. Inter-observer agreement for all parameters was good to excellent. Conclusion For fiber tractography and DTI of the ulnar nerve at the cubital tunnel, optimal image quality was obtained using a 1.3-mm(2)pixel size and 4-mm slice thickness under MR parameters of this study at 3T.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 20 条
[1]   Diffusion tensor imaging and fiber tractography of the median nerve at 1.5T: optimization of b value [J].
Andreisek, Gustav ;
White, Lawrence M. ;
Kassner, Andrea ;
Tomlinson, George ;
Sussman, Marshall S. .
SKELETAL RADIOLOGY, 2009, 38 (01) :51-59
[2]   Peripheral Neuropathy: Detection with Diffusion-Tensor Imaging [J].
Baeumer, Philipp ;
Pham, Mirko ;
Ruetters, Maurice ;
Heiland, Sabine ;
Heckel, Andreas ;
Radbruch, Alexander ;
Bendszus, Martin ;
Weiler, Markus .
RADIOLOGY, 2014, 273 (01) :185-193
[3]   Ulnar Neuropathy at the Elbow: MR Neurography-Nerve T2 Signal Increase and Caliber [J].
Baeumer, Philipp ;
Dombert, Thomas ;
Staub, Frank ;
Kaestel, Thorsten ;
Bartsch, Andreas J. ;
Heiland, Sabine ;
Bendszus, Martin ;
Pham, Mirko .
RADIOLOGY, 2011, 260 (01) :199-206
[4]   Clinical, electrodiagnostic, and sonographic studies in ulnar neuropathy at the elbow [J].
Beekman, R ;
Van Der Plas, JPL ;
Uitdehaag, BMJ ;
Schellens, RLLA ;
Visser, LH .
MUSCLE & NERVE, 2004, 30 (02) :202-208
[5]   MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study [J].
Breitenseher, Julia B. ;
Kranz, Gottfried ;
Hold, Alina ;
Berzaczy, Dominik ;
Nemec, Stefan F. ;
Sycha, Thomas ;
Weber, Michael ;
Prayer, Daniela ;
Kasprian, Gregor .
EUROPEAN RADIOLOGY, 2015, 25 (07) :1911-1918
[6]   Effects of signal-to-noise ratio on the accuracy and reproducibility, of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T [J].
Farrell, Jonathan A. D. ;
Landman, Bennett A. ;
Jones, Craig K. ;
Smith, Seth A. ;
Prince, Jerry L. ;
van Zijl, Peter C. M. ;
Mori, Susumu .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) :756-767
[7]   MR neurography of the median nerve at 3.0T: Optimization of diffusion tensor imaging and fiber tractography [J].
Guggenberger, Roman ;
Eppenberger, Patrick ;
Markovic, Daniel ;
Nanz, Daniel ;
Chhabra, Avneesh ;
Pruessmann, Klaas P. ;
Andreisek, Gustav .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :E775-E782
[8]   Evaluation of skeletal muscle DTI in patients with duchenne muscular dystrophy [J].
Hooijmans, M. T. ;
Damon, B. M. ;
Froeling, M. ;
Versluis, M. J. ;
Burakiewicz, J. ;
Verschuuren, J. J. G. M. ;
Niks, E. H. ;
Webb, A. G. ;
Kan, H. E. .
NMR IN BIOMEDICINE, 2015, 28 (11) :1589-1597
[9]   Elbow Nerves: MR Findings in 60 Asymptomatic Subjects-Normal Anatomy, Variants, and Pitfalls [J].
Husarik, Daniela B. ;
Saupe, Nadja ;
Pfirrmann, Christian W. A. ;
Jost, Bernhard ;
Hodler, Jurg ;
Zanetti, Marco .
RADIOLOGY, 2009, 252 (01) :148-156
[10]   Peripheral nerve diffusion tensor imaging: Overview, pitfalls, and future directions [J].
Jeon, Tina ;
Fung, Maggie M. ;
Koch, Kevin M. ;
Tan, Ek T. ;
Sneag, Darryl B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (05) :1171-1189