Preparation, characterization, and application of a porous poly (TAIC-co-MMA-co-EDMA) monolithic column for small molecules of aromatics and Chinese herbal medicine notoginseng by HPLC

被引:16
作者
Wang, Quan [1 ,2 ]
Shen, Shigang [1 ]
机构
[1] Hebei Univ, Coll Chem & Environm Sci, Key Lab Analyt Sci & Technol Hebei Prov, Baoding 071002, Peoples R China
[2] Agr Univ Hebei, Coll Life Sci, Baoding 071001, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
High performance liquid chromatography; Triallyl isocyanurate; Monolithic column; Preparation; Small molecules; Notoginseng; PERFORMANCE LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; IONIC LIQUID; CAPILLARY COLUMNS; POLY(LACTIC ACID); SEPARATION; FABRICATION; PROTEIN; POLYMERIZATION;
D O I
10.1016/j.talanta.2018.09.112
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel porous monolithic column was synthesized via in situ free-radical polymerization within a stainless steel column (50 x 4.6 mm i.d.) by using triallyl isocyanurate and methyl methacrylate as co-monomers, ethylene glycol dimethacrylate as a crosslinking agent, 1,4-butanediol, 1-dodecanol, and N, N-dimethylformamide as tri-porogens, and azobisisobutyronitrile as an initiator. The optimized monolithic columns were investigated by scanning electron microscopy, a nitrogen absorption-desorption apparatus, and mercury intrusion porosimetry. The effect of mobile phase composition and temperature on chromatographic behavior was studied in detail as well. The results showed that homemade monolithic columns not only have relative uniform porosity structure, low back pressure, and high thermal stability, but also show high column efficiency, the theoretical plates number of the new polymer monolithic column exceeded 31,000 plates m(-1). Good resolution was achieved for HPLC separation of small molecules, including polycyclic aromatic hydrocarbons, isomers of phenols, and the Chinese herbal medicine notoginseng. Methodological validation of six drugs in notoginseng show that correlation coefficients of the linear regressions were in the range of 0.9989-0.9997; the value of relative standard deviation for precision were in the range of 1.37-4.21% for intra-day and 0.34-5.31% for inter-day, respectively; the values of accuracy expressed by recovery were in the range of 100.57-102.51%, 95.18-102.68%, 101.61-102.82%, 100.94-102.40%, 100.99-103.15% and 99.49-103.91% for the six drugs in order, respectively. Taking aromatic hydrocarbons as samples, the relative standard deviation values of the run-to-run (n = 5) and column-to-column (n = 5) based on peak area were < 2.01% and 2.39%, and two RSDs based on retention time were < 2.56% and 2.23%, respectively. The result showed that the polymer monolithic column has good separation ability and high permeability for small molecular substances.
引用
收藏
页码:649 / 657
页数:9
相关论文
共 47 条
  • [1] Preparation of a novel porous poly (trimethylol propane triacrylate-co-ethylene dimethacrylate) monolithic column for highly efficient HPLC separations of small molecules
    Bai, Xiaomei
    Liu, Haiyan
    Wei, Dan
    Yang, Gengliang
    [J]. TALANTA, 2014, 119 : 479 - 484
  • [2] Novel monolithic materials using poly(ethylene glycol) as porogen for protein separation
    Courtois, J
    Byström, E
    Irgum, K
    [J]. POLYMER, 2006, 47 (08) : 2603 - 2611
  • [3] Perspectives on the Evolution of the Column Efficiency in Liquid Chromatography
    Gritti, Fabrice
    Guiochon, Georges
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (06) : 3017 - 3035
  • [4] Hypercrosslinked cholesterol-based polystyrene monolithic capillary columns
    Grzywinski, D.
    Szumski, M.
    Buszewski, B.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1477 : 11 - 21
  • [5] Monolithic columns in high-performance liquid chromatography
    Guiochon, Georges
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) : 101 - 168
  • [6] Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography
    Gusev, I
    Huang, X
    Horváth, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 273 - 290
  • [7] Polymeric ionic liquid modified organic-silica hybrid monolithic column for capillary electrochromatography
    Han, Haifeng
    Wang, Qing
    Liu, Xia
    Jiang, Shengxiang
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1246 : 9 - 14
  • [8] Fast preparation of a hydrophobic monolith by redox initiation and its application in the separation of small molecules
    Hao, Mengbei
    Zhong, Jing
    Li, Ruo
    Li, Haijing
    Bai, Ligai
    Yang, Gengliang
    [J]. ANALYTICAL METHODS, 2014, 6 (08) : 2655 - 2661
  • [9] New Monolithic Capillary Columns with Well-Defined Macropores Based on Poly(styrene-co-divinylbenzene)
    Hasegawa, George
    Kanamori, Kazuyoshi
    Ishizuka, Norio
    Nakanishi, Kazuki
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (05) : 2343 - 2347
  • [10] Fabrication of highly crosslinked methacrylate-based polymer monoliths with well-defined macropores via living radical polymerization
    Hasegawa, George
    Kanamori, Kazuyoshi
    Nakanishi, Kazuki
    Yamago, Shigeru
    [J]. POLYMER, 2011, 52 (21) : 4644 - 4647