Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients: 24-month follow-up study

被引:21
作者
Iglicki, Matias [1 ]
Zur, Dinah [2 ]
Negri, Hermino Pablo [3 ]
Esteves, Joaquin [3 ]
Arias, Romina [3 ]
Holsman, Emanuel [3 ]
Loewenstein, Anat [2 ]
Busch, Catharina [4 ]
机构
[1] Univ Buenos Aires, Retina Private Off, 525 Aguirre St,3rd Floor,Apt A, RA-1414 Buenos Aires, DF, Argentina
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Med Ctr, Div Ophthalmol, Tel Aviv, Israel
[3] Diagnost Ophthalmol Ctr, Buenos Aires, DF, Argentina
[4] Univ Leipzig, Dept Ophthalmol, Leipzig, Germany
关键词
Diabetes mellitus; Aphakia; Sutureless intraocular lens fixation; Flanged technique; 27; Gauge; 30; Ultrasound biomicroscopy; SCLERAL FIXATION; ANTERIOR-CHAMBER; OPEN-LOOP; IMPLANTATION;
D O I
10.1007/s00592-020-01530-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. Methods Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n= 51) or a 30G ultrathin wall (UTW) needle technique (n= 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. Results IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 +/- 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). Conclusions Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.
引用
收藏
页码:1151 / 1157
页数:7
相关论文
共 16 条
[1]   Posterior iris fixation of the iris-claw intraocular lens implantation through a scleral tunnel incision [J].
Baykara, Mehmet ;
Ozcetin, Hikmet ;
Yilmaz, Sami ;
Timucin, Oezgur Buelent .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (04) :586-591
[2]   Effects of Age and Diabetes on Scleral Stiffness [J].
Coudrillier, Baptiste ;
Pijanka, Jacek ;
Jefferys, Joan ;
Sorensen, Thomas ;
Quigley, Harry A. ;
Boote, Craig ;
Nguyen, Thao D. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (07)
[3]   Scleral fixation of a foldable intraocular lens with polytetrafluoroethylene sutures through a Hoffman pocket [J].
Das, Sudeep ;
Nicholson, Maneck ;
Deshpande, Kalyani ;
Kummelil, Mathew Kurian ;
Nagappa, Somshekar ;
Shetty, Bhujang K. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07) :955-960
[4]   Long-term follow-up of secondary flexible, open-loop, anterior chamber intraocular lenses [J].
Drolsum, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (03) :498-503
[5]   Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses [J].
Evereklioglu, C ;
Er, H ;
Bekir, NA ;
Borazan, M ;
Zorlu, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02) :301-308
[6]  
Gelman Rachel A, 2019, Am J Ophthalmol Case Rep, V14, P101, DOI 10.1016/j.ajoc.2019.03.009
[7]   CHARACTERIZATION OF COLLAGEN FROM NORMAL HUMAN SCLERA [J].
KEELEY, FW ;
MORIN, JD ;
VESELY, S .
EXPERIMENTAL EYE RESEARCH, 1984, 39 (05) :533-542
[8]   Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile [J].
Khan, M. Ali ;
Gupta, Omesh P. ;
Smith, Ryan G. ;
Ayres, Brandon D. ;
Raber, Irving M. ;
Bailey, Robert S. ;
Hsu, Jason ;
Spirn, Marc J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (05) :638-643
[9]   Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation [J].
Matsui, Yoshitsugu ;
Matsubara, Hisashi ;
Hanemoto, Tsukasa ;
Kondo, Mineo .
BMC OPHTHALMOLOGY, 2015, 15
[10]   Biomechanical Impact of the Sclera on Corneal Deformation Response to an Air-Puff: A Finite-Element Study [J].
Nguyen, B. Audrey ;
Roberts, Cynthia J. ;
Reilly, Matthew A. .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2019, 6 (JAN)