Skin flora and bacterial contamination of diversion pouch and recovered platelet components in Moroccan blood donors

被引:4
作者
El Mehdaoui, Fatna [1 ,2 ]
Benajiba, Mohammed [3 ]
Boulahdid, Safia [3 ]
El Hattimy, Faical [2 ]
Soulaymani, Abdelmajid [2 ]
Alami, Raouf [1 ]
机构
[1] Higher Inst Nursing Profess & Hlth Tech Rabat ISP, Res Lab, Rabat, Morocco
[2] Ibn Tofail Univ, Sch Sci, Genet & Biometry Lab, Kenitra, Morocco
[3] Reg Blood Transfus Ctr CRTS, Rabat, Morocco
关键词
antecubital fossa; bacterial contamination; blood donor; blood safety; diversion pouch; platelet components; TRANSFUSION; RISK; COLLECTION; RESISTANT; DONATION;
D O I
10.1111/tme.12704
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The objective of this study was to evaluate bacterial reduction procedures used during whole-blood donations in Morocco. Background Bacterial contamination still poses serious challenges to blood safety, especially in countries with limited resources. Methods In the first part of this study, we analysed 233 swab samples taken from blood donors' antecubital fossa. After donation, a second batch of samples was analysed from the diversion pouches of corresponding donors. In addition, we searched for the prevalence of bacterial contamination in 568 randomly chosen platelet components at their expiration date in order to control for the entire blood unit preparation process. Results The most frequently found bacterial species at the antecubital fossa of healthy blood donors were coagulase-negativeStaphylococcus, aerophilicCorynebacterium,Staphylococcus aureus,Bacillussp. andMicrococcussp. After donation, 5.15% of the diversion pouches were contaminated with bacterial species, the most notable beingBacillussp., aerophilicCorynebacterium, coagulase-negativeStaphylococcus,Staphylococcus aureusandPseudomonas aeruginosa. Of 568 platelet components, 18 were contaminated with three bacterial species:Bacillussp., coagulase-negativeStaphylococcusandStaphylococcus aureus. Conclusion All three bacterial species found in platelet components were detected on the skin of blood donors. Serious measures need to be taken and enforced to ensure blood safety.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 34 条
[31]   Bacterial Contamination and Susceptibility Pattern Among Blood and Blood Components Using Divergent and Non-Divergent Collection Methods at Armed Forces Comprehensive Specialized Hospital, Addis Ababa, Ethiopia [J].
Tsegaye, Wondwossen ;
Bitew, Adane ;
Gize, Addisu .
INFECTION AND DRUG RESISTANCE, 2022, 15 :1677-1686
[32]   Detection of bacterial contamination in platelet concentrates from Brazilian donors by molecular amplification of the ribosomal 16S gene [J].
Viana, J. D. ;
Ferreira, S. C. ;
Matana, S. R. ;
Rossi, F. ;
Patel, P. ;
Garson, J. A. ;
Rocha, V. ;
Tedder, R. ;
Mendrone-Junior, A. ;
Levi, J. E. .
TRANSFUSION MEDICINE, 2018, 28 (06) :420-426
[33]   Reflections on the dynamics of bacterial and viral contamination of blood components and the levels of efficacy for pathogen inactivation processes [J].
Bah, Aicha ;
Cardoso, Marcia ;
Seghatchian, Jerard ;
Goodrich, Raymond P. .
TRANSFUSION AND APHERESIS SCIENCE, 2018, 57 (05) :683-688
[34]   Verification of a method using magnetic bead enrichment and nucleic acid extraction to improve the molecular detection of bacterial contamination in blood components [J].
Na, Byungjoon ;
Lee, Jinyeop ;
Chang, Ho Eun ;
Park, Eunseon ;
Park, Sojin ;
Lee, Jiyoung ;
Oh, Sujin ;
Shin, Dong Woo ;
Hong, Yun Ji ;
Park, Kyoung Un .
MICROBIOLOGY SPECTRUM, 2024, 12 (03)