Skin flora and bacterial contamination of diversion pouch and recovered platelet components in Moroccan blood donors

被引:4
作者
El Mehdaoui, Fatna [1 ,2 ]
Benajiba, Mohammed [3 ]
Boulahdid, Safia [3 ]
El Hattimy, Faical [2 ]
Soulaymani, Abdelmajid [2 ]
Alami, Raouf [1 ]
机构
[1] Higher Inst Nursing Profess & Hlth Tech Rabat ISP, Res Lab, Rabat, Morocco
[2] Ibn Tofail Univ, Sch Sci, Genet & Biometry Lab, Kenitra, Morocco
[3] Reg Blood Transfus Ctr CRTS, Rabat, Morocco
关键词
antecubital fossa; bacterial contamination; blood donor; blood safety; diversion pouch; platelet components; TRANSFUSION; RISK; COLLECTION; RESISTANT; DONATION;
D O I
10.1111/tme.12704
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The objective of this study was to evaluate bacterial reduction procedures used during whole-blood donations in Morocco. Background Bacterial contamination still poses serious challenges to blood safety, especially in countries with limited resources. Methods In the first part of this study, we analysed 233 swab samples taken from blood donors' antecubital fossa. After donation, a second batch of samples was analysed from the diversion pouches of corresponding donors. In addition, we searched for the prevalence of bacterial contamination in 568 randomly chosen platelet components at their expiration date in order to control for the entire blood unit preparation process. Results The most frequently found bacterial species at the antecubital fossa of healthy blood donors were coagulase-negativeStaphylococcus, aerophilicCorynebacterium,Staphylococcus aureus,Bacillussp. andMicrococcussp. After donation, 5.15% of the diversion pouches were contaminated with bacterial species, the most notable beingBacillussp., aerophilicCorynebacterium, coagulase-negativeStaphylococcus,Staphylococcus aureusandPseudomonas aeruginosa. Of 568 platelet components, 18 were contaminated with three bacterial species:Bacillussp., coagulase-negativeStaphylococcusandStaphylococcus aureus. Conclusion All three bacterial species found in platelet components were detected on the skin of blood donors. Serious measures need to be taken and enforced to ensure blood safety.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 34 条
[21]   Evaluation of bacterial contamination of blood components in a tertiary care centre [J].
Sehgal, Shivali ;
Prakhya, Lalita Jyotsna .
BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2022, 21 (01) :213-216
[22]   Bacterial Contamination of Platelet Components: Prevalence and Measures to Prevent Transfusion-Transmitted Bacterial Infection [J].
Corash, Laurence .
PROGRESS AND CHALLENGES IN TRANSFUSION MEDICINE, HEMOSTASIS AND HEMOTHERAPY: STATE OF THE ART 2008, 2008, :234-247
[23]   Bacterial contamination of platelet products in the Blood Transfusion Center of Isfahan, Iran [J].
Farzad, Baghi Baghban ;
Farshad, Baghban ;
Zahra, Bamzadeh ;
Nahid, Akbari ;
Mahsa, Khosravi Bakhtiari .
GMS HYGIENE AND INFECTION CONTROL, 2016, 11
[24]   Impact of donor arm skin disinfection on the bacterial contamination rate of platelet concentrates [J].
Lee, CK ;
Ho, PL ;
Chan, NK ;
Mak, A ;
Hong, J ;
Lin, CK .
VOX SANGUINIS, 2002, 83 (03) :204-208
[25]   The use of an integumental sealer to reduce bacterial contamination by the endogeous skin flora during surgery in the horse [J].
Grossheim, Birke ;
Koene, Marc .
PFERDEHEILKUNDE, 2012, 28 (05) :594-596
[26]   Bacterial contamination of platelet components: potential solutions to prevent transfusion-related sepsis [J].
Corash, Laurence .
EXPERT REVIEW OF HEMATOLOGY, 2011, 4 (05) :509-525
[27]   Comparing two blood culture systems for the detection of bacterial contamination in platelet concentrates [J].
Chetouane, Yasmine ;
Gallian, Pierre ;
Chetouane, Kahina ;
Dubourg, Gregory ;
Chiaroni, Jacques ;
Raoult, Didier ;
Camoin-Jau, Laurence .
TRANSFUSION, 2018, 58 (11) :2604-2610
[28]   Implementation of a blood proficiency testing scheme for bacterial screening of platelet components [J].
Prax, Marcel ;
Debes, Lea ;
Chudy, Michael ;
Filomena, Angela ;
Pisani, Giulio ;
Pupella, Simonetta ;
Riley, Marie ;
Sondag-Thull, Daniele ;
Hecquet, Marie-Laure ;
Emery, Marie Pierre ;
Pflieger, Marie ;
Arnould, Perrine .
VOX SANGUINIS, 2025, 120 (04) :401-410
[29]   Bacterial contamination rate of platelet components by primary culture: a systematic review and meta-analysis [J].
White, Sandra K. ;
Schmidt, Robert L. ;
Walker, Brandon S. ;
Metcalf, Ryan A. .
TRANSFUSION, 2020, 60 (05) :986-996
[30]   Efficiency of diversion of the first aliquot of blood and prestorage leukoreduction for preventing bacterial contamination in red blood cell concentrates assessed using a rapid polymerase chain reaction-based bacterial detection system [J].
Nakamura, A. ;
Abe, K. ;
Masuya, M. ;
Imai, S. ;
Ohishi, K. ;
Mori, Y. ;
Kojima, T. ;
Wada, H. ;
Katayama, N. ;
Nobori, T. .
TRANSFUSION MEDICINE, 2011, 21 (06) :365-370