Assessment of Diabetic Retinopathy Using Nonmydriatic Ultra-Widefield Scanning Laser Ophthalmoscopy (Optomap) Compared With ETDRS 7-Field Stereo Photography

被引:97
作者
Kernt, Marcus [1 ]
Hadi, Indrawati [1 ]
Pinter, Florian [1 ]
Seidensticker, Florian [1 ]
Hirneiss, Christoph [1 ]
Haritoglou, Christos [1 ]
Kampik, Anselm [1 ]
Ulbig, Michael W. [1 ]
Neubauer, Aljoscha S. [1 ]
机构
[1] Univ Munich, Dept Ophthalmol, Munich, Germany
关键词
MACULAR EDEMA; COST-EFFECTIVENESS; SPECIFICITY; SENSITIVITY;
D O I
10.2337/dc12-0346
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE-To compare the diagnostic properties of a nonmydriatic 200 degrees ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. RESEARCH DESIGN AND METHODS-A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. RESULTS-Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no ormild DR (ETDRS levels <= 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with kappa = 0.79 for DR and 0.73 for CSME for grader 1, and kappa = 0.77 (DR) and 0.77 (CSME) for grader 2. CONCLUSIONS-Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties. Diabetes Care 35: 2459-2463, 2012
引用
收藏
页码:2459 / 2463
页数:5
相关论文
共 31 条
  • [1] STATISTICS IN MEDICAL JOURNALS - DEVELOPMENTS IN THE 1980S
    ALTMAN, DG
    [J]. STATISTICS IN MEDICINE, 1991, 10 (12) : 1897 - 1913
  • [2] American Academy of Ophthalmology Retina/Vitreous Panel Preferred Practice Patterns Committee, 2008, DIAB RET
  • [3] [Anonymous], 1985, JAMA-J AM MED ASSOC, V254, P3086
  • [4] Screening of diabetic retinopathy: Effect of field number and mydriasis on sensitivity and specificity of digital fundus photography
    Aptel, F.
    Denis, P.
    Rouberol, F.
    Thivolet, C.
    [J]. DIABETES & METABOLISM, 2008, 34 (03) : 290 - 293
  • [5] Blanckenberg M., 2011, 2011 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, P5236, DOI 10.1109/IEMBS.2011.6091295
  • [6] Screening for diabetic retinopathy in rural areas: The potential of telemedicine
    Cummings, DM
    Morrissey, S
    Barondes, MJ
    Rogers, L
    Gustke, S
    [J]. JOURNAL OF RURAL HEALTH, 2001, 17 (01) : 25 - 31
  • [7] Imaging of Diabetic Retinopathy and Diabetic Macular Edema
    Danis, Ronald P.
    Hubbard, Larry D.
    [J]. CURRENT DIABETES REPORTS, 2011, 11 (04) : 236 - 243
  • [8] DCCT Res Grp, 1991, AM J MED, V90, P450, DOI 10.1016/0002-9343(91)80085-Z
  • [9] Diabetic macular oedema: physical, physiological and molecular factors contribute to this pathological process
    Ehrlich, Rita
    Harris, Alon
    Ciulla, Thomas A.
    Kheradiya, Nisha
    Winston, Diana M.
    Wirostko, Barbara
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (03) : 279 - 291
  • [10] Fendrick A M, 1992, Int J Technol Assess Health Care, V8, P694