Motion correction for infant functional near-infrared spectroscopy with an application to live interaction data

被引:27
作者
Behrendt, Hannah F. [1 ,2 ]
Firk, Christine [2 ]
Nelson, Charles A., III [1 ,3 ,4 ]
Perdue, Katherine L. [1 ,3 ]
机构
[1] Boston Childrens Hosp, Labs Cognit Neurosci, Boston, MA 02115 USA
[2] Univ Hosp RWTH Aachen, Child Neuropsychol Sect, Dept Child & Adolescent Psychiat, Psychosomat & Psychotherapy, Aachen, Germany
[3] Harvard Med Sch, Boston, MA 02115 USA
[4] Harvard Grad Sch Educ, Cambridge, MA USA
关键词
functional near-infrared spectroscopy; motion correction; simulation; infant; live stimulus presentation; OPTICAL PATHLENGTH; ARTIFACTS; RESPONSES; TISSUE;
D O I
10.1117/1.NPh.5.1.015004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Correcting for motion is an important consideration in infant functional near-infrared spectroscopy studies. We tested the performance of conventional motion correction methods and compared probe motion and data quality metrics for data collected at different infant ages (5, 7, and 12 months) and during different methods of stimulus presentation (video versus live). While 5-month-olds had slower maximum head speed than 7- or 12-month-olds, data quality metrics and hemodynamic response recovery errors were similar across ages. Data quality was also similar between video and live stimulus presentation. Motion correction algorithms, such as wavelet filtering and targeted principal component analysis, performed well for infant data using infant-specific parameters, and parameters may be used without fine-tuning for infant age or method of stimulus presentation. We recommend using wavelet filtering with iqr = 0.5; however, a range of parameters seemed acceptable. We do not recommend using trial rejection alone, because it did not improve hemodynamic response recovery as compared to no correction at all. Data quality metrics calculated from uncorrected data were associated with hemodynamic response recovery error, indicating that full simulation studies may not be necessary to assess motion correction performance. (c) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:16
相关论文
共 28 条
  • [1] Hemodynamic Correlates of Cognition in Human Infants
    Aslin, Richard N.
    Shukla, Mohinish
    Emberson, Lauren L.
    [J]. ANNUAL REVIEW OF PSYCHOLOGY, VOL 66, 2015, 66 : 349 - 379
  • [2] Postnatal Mother-to-Infant Attachment in Subclinically Depressed Mothers: Dyads at Risk?
    Behrendt, Hannah F.
    Konrad, Kerstin
    Goecke, Tamme W.
    Fakhrabadi, Roya
    Herpertz-Dahlmann, Beate
    Firk, Christine
    [J]. PSYCHOPATHOLOGY, 2016, 49 (04) : 269 - 276
  • [3] Automatic Detection of Motion Artifacts in Infant Functional Optical Topography Studies
    Blasi, Anna
    Phillips, Derrick
    Lloyd-Fox, Sarah
    Koh, Peck Hui
    Elwell, Clare E.
    [J]. OXYGEN TRANSPORT TO TISSUE XXXI, 2010, 662 : 279 - 284
  • [4] Motion artifacts in functional near-infrared spectroscopy: A comparison of motion correction techniques applied to real cognitive data
    Brigadoi, Sabrina
    Ceccherini, Lisa
    Cutini, Simone
    Scarpa, Fabio
    Scatturin, Pietro
    Selb, Juliette
    Gagnon, Louis
    Boas, David A.
    Cooper, Robert J.
    [J]. NEUROIMAGE, 2014, 85 : 181 - 191
  • [5] A kurtosis-based wavelet algorithm for motion artifact correction of fNIRS data
    Chiarelli, Antonio M.
    Maclin, Edward L.
    Fabiani, Monica
    Gratton, Gabriele
    [J]. NEUROIMAGE, 2015, 112 : 128 - 137
  • [6] A systematic comparison of motion artifact correction techniques for functional near-infrared spectroscopy
    Cooper, Robert J.
    Seib, Juliette
    Gagnon, Louis
    Phillip, Dorte
    Schytz, Henrik W.
    Iversen, Helle K.
    Ashina, Messoud
    Boas, David A.
    [J]. FRONTIERS IN NEUROSCIENCE, 2012, 6
  • [7] SYSTEM FOR LONG-TERM MEASUREMENT OF CEREBRAL BLOOD AND TISSUE OXYGENATION ON NEWBORN-INFANTS BY NEAR-INFRARED TRANS-ILLUMINATION
    COPE, M
    DELPY, DT
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (03) : 289 - 294
  • [8] ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT
    DELPY, DT
    COPE, M
    VANDERZEE, P
    ARRIDGE, S
    WRAY, S
    WYATT, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) : 1433 - 1442
  • [9] OPTICAL PATHLENGTH MEASUREMENTS ON ADULT HEAD, CALF AND FOREARM AND THE HEAD OF THE NEWBORN-INFANT USING PHASE-RESOLVED OPTICAL SPECTROSCOPY
    DUNCAN, A
    MEEK, JH
    CLEMENCE, M
    ELWELL, CE
    TYSZCZUK, L
    COPE, M
    DELPY, DT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) : 295 - 304
  • [10] Exploring the neural basis of real-life joint action: measuring brain activation during joint table setting with functional near-infrared spectroscopy
    Egetemeir, Johanna
    Stenneken, Prisca
    Koehler, Saskia
    Fallgatter, Andreas J.
    Herrmann, Martin J.
    [J]. FRONTIERS IN HUMAN NEUROSCIENCE, 2011, 5