Clinical Outcomes of Sentinel Cerebral Protection System Use During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

被引:31
作者
Ndunda, Paul M. [1 ]
Vindhyal, Mohinder R. [1 ]
Muutu, Tabitha M. [1 ]
Fanari, Zaher [1 ,2 ]
机构
[1] Univ Kansas, Sch Med Wichita, Internal Med, 1010 N Kansas St, Wichita, KS 67214 USA
[2] Univ Kansas, Sch Med Wichita, Wesley Med Ctr, Heartland Cardiol, 551 N Hillside,Suite 520, Wichita, KS 67214 USA
关键词
Transcatheter aortic valve replacement; Sentinel Cerebral Protection System; Cerebral embolic protection device; Stroke; Systematic review and meta-analysis; EMBOLIC PROTECTION; RISK-FACTORS; IMPLANTATION; STROKE; STENOSIS; TAVI; DEVICES;
D O I
10.1016/j.carrev.2019.04.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare the clinical outcomes following transcatheter aortic valve replacement (TAVR) with and without the use of the Sentinel Cerebral Protection System (Sentinel CPS). Background: Stroke occurs in 2-5% of patients at 30 days after TAVR and increases mortality >3 fold. The Sentinel CPS is the only FDA (Food and Drug Administration) approved cerebral embolic protection device. Methods: The Cochrane Library, PubMed and Web of Science were searched for relevant studies for inclusion in the meta-analysis. Two authors independently screened and included studies comparing the clinical outcomes after TAVR with and without the Sentinel CPS. Risk of bias was assessed using the Cochrane tools (RoB2.0 and ROBINS-I). Results: Four studies comparing 606 patients undergoing TAVR with Sentinel CPS to 724 without any embolic protection device were included. Sentinel CPS use was associated with lower rates of 30-day mortality [0.8% vs 2.7%; RR 0.34 (95% CI 0.12, 0.92) I-2 = 0%], 30-day symptomatic stroke [3.5% vs 6.1%; RR 0.51 (95% CI 0.29, 0.90) I-2 = 0] and major or life-threatening bleeding [3.3% vs 6.6%; RR 0.50 (0.26, 0.98) I-2 = 16%]. There was no significant difference between the two arms in the incidence of acute kidney injury [0.8% vs 1%; RR 0.85 (95% CI 0.22, 3.24) I-2 = 0%] and major vascular complications [5.1% vs 6%; RR 0.74 (0.33, 1.67) I-2 = 45%]. Conclusion: The results suggest that Sentinel CPS use in TAVR is associated with a lower risk of stroke, mortality and major or life-threatening bleeding at 30 days. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:717 / 722
页数:6
相关论文
共 35 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation Systematic Review and Meta-Analysis [J].
Bagur, Rodrigo ;
Solo, Karla ;
Alghofaili, Saleh ;
Nombela-Franco, Luis ;
Kwok, Chun Shing ;
Hayman, Samual ;
Siemieniuk, Reed A. ;
Foroutan, Farid ;
Spencer, Frederick A. ;
Vandvik, Per O. ;
Schaeufele, Tim G. ;
Mamas, Mamas A. .
STROKE, 2017, 48 (05) :1306-+
[3]  
Claret Medical, 2017, CLAR MED REC FDA CLE
[4]   Stroke Associated With Surgical and Transcatheter Treatment of Aortic Stenosis A Comprehensive Review [J].
Daneault, Benoit ;
Kirtane, Ajay J. ;
Kodali, Susheel K. ;
Williams, Mathew R. ;
Genereux, Philippe ;
Reiss, George R. ;
Smith, Craig R. ;
Moses, Jeffrey W. ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2143-2150
[5]   Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients [J].
Eggebrecht, Holger ;
Schmermund, Axel ;
Voigtlaender, Thomas ;
Kahlert, Philipp ;
Erbel, Raimund ;
Mehta, Rajendra H. .
EUROINTERVENTION, 2012, 8 (01) :129-138
[6]   Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status [J].
Fairbairn, Timothy A. ;
Mather, Adam N. ;
Bijsterveld, Petra ;
Worthy, Gillian ;
Currie, Stuart ;
Goddard, Anthony J. P. ;
Blackman, Daniel J. ;
Plein, Sven ;
Greenwood, John P. .
HEART, 2012, 98 (01) :18-23
[7]   Cerebral Embolic Protection During TAVR A Clinical Event Meta-Analysis [J].
Giustino, Gennaro ;
Sorrentino, Sabato ;
Mehran, Roxana ;
Faggioni, Michela ;
Dangas, George .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (04) :465-466
[8]   Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[9]  
Hodonsky CJ, 2017, CIRCULATION, V135
[10]  
Holmes DR Jr, 2012, J THORAC CARDIOV SUR, V144, pE29, DOI 10.1016/j.jtcvs.2012.03.001