Study of Pulsed Magnetic Field Generator for Magnetoacoustic Tomography Technology with Magnetic Induction

被引:0
作者
Li, Yanhong [1 ]
Liu, Guoqiang [1 ]
Li, Shiqiang [1 ]
Xia, Hui [1 ]
机构
[1] Chinese Acad Sci, Dept Frontiers Elect Engn, Inst Elect Engn, Beijing, Peoples R China
来源
MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8 | 2012年 / 383-390卷
关键词
magnetoacoustic tomography with magnetic Induction; pulsed magnetic field; discharging system; detective coil; IMAGING ELECTRICAL-IMPEDANCE; PARALLEL RESONANT CONVERTER; MAT-MI; SIMULATION;
D O I
10.4028/www.scientific.net/AMR.383-390.805
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
On the basis of contrasting the research of home and abroad, this paper studies array magnetoacoustic tomography with magnetic induction as well logging new method. The paper introduces the design of the pulsed magnetic field for magnetoacoustic tomography with magnetic induction, analyses operational principle and parameters of charging system, introduces the operation mode of the discharging system in detail, the constitution of key parts circular plate coil, and realizes narrow width, high peak and repeat pulsed current with inductive load finally, and we obtained the distribution of the magnetic field. Magnetoacoustic tomography with magnetic induction combines the technology of Electrical Impedance Tomography and ultrasonic imaging, it can provide an impedance image with good accuracy and high spatial resolution, the method has a good prospect of application and extension in detection of resource, medical imaging and other fields.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 12 条
[1]   Series-parallel resonant converter operating in discontinuous current mode - Analysis, design, simulation, and experimental results [J].
Belaguli, V ;
Bhat, AKS .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2000, 47 (04) :433-442
[2]  
[杜涛 Du Tao], 2004, [探测与控制学报, Journal of detection & control], V26, P42
[3]  
Li Wei, 2003, J BEIJING I PETROCHE, V11, P13
[4]   Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue [J].
Li, X ;
Xu, Y ;
He, B .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (06)
[5]   Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI) [J].
Li, Xu ;
Xu, Yuan ;
He, Bin .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (02) :323-330
[6]  
Li X, 2006, I S BIOMED IMAGING, P1088
[7]  
Lu Jun-qiang, 2009, High Voltage Engineering, V35, P324
[8]   ANALYSIS AND IMPLEMENTATION OF A FULL-BRIDGE CONSTANT-FREQUENCY LCC-TYPE PARALLEL RESONANT CONVERTER [J].
TSAI, MC .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1994, 141 (03) :121-128
[9]  
WANG H, 2007, P NFSI ICFBI, P290
[10]  
Wang HF, 2008, BIORESOURCES, V3, P3