Experimental and numerical investigations on the thermal performance of a borehole ground heat exchanger with PCM backfill

被引:78
作者
Yang, Weibo [1 ,2 ,3 ]
Xu, Rui [1 ]
Yang, Binbin [1 ]
Yang, Jingjing [1 ]
机构
[1] Yangzhou Univ, Sch Hydraul Energy & Power Engn, Yangzhou 225127, Jiangsu, Peoples R China
[2] China Univ Min & Technol, State Key Lab GeoMech & Deep Underground Engn, Xuzhou 221008, Jiangsu, Peoples R China
[3] Xi An Jiao Tong Univ, Minist Educ, Key Lab Thermofluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Borehole ground heat exchanger; PCM backfill; Thermal performance; Experimental investigation; Numerical simulation; PHASE-CHANGE MATERIALS; ENERGY STORAGE; PUMP SYSTEM;
D O I
10.1016/j.energy.2019.02.172
中图分类号
O414.1 [热力学];
学科分类号
摘要
Borehole ground heat exchanger (BGHE) with phase change material (PCM) backfill is a new type of efficient geothermal energy utilization technology. In this paper, a simulation experimental system on the thermal performance of BGHE with PCM backfill has been built. The experimental performance investigations of the BGHE operated in summer and winter modes have been conducted. The results indicate that the soil thermal interference radius with PCM backfill are about 86.5% and 87.8% of that with soil backfill for summer and winter modes, respectively. At the same time, the PCM backfill can increase the heat exchange rate of BGHE and delay the variation of soil temperature due to the latent heat release of PCM during the phase change. The mass ratio of mixed acid to oleic acid content has great influence on the soil thermal interference radius and heat transfer rate of BGHE. The minimum soil thermal interference radius throughout the year is found to be 0.47 mat the mass ratio of 4:6 under the test conditions, and the corresponding total heat transfer of BGHE are 16146.09 and 4966.13 kJ for summer and winter mode, respectively. To further study the effects of thermal properties of PCM, running time and alternate cooling and heating operation, numerical simulation on the influences of phase change temperatures, latent heats, different time ratios of operation to off and alternate cooling and heating cycle on the soil temperature variation and energy storage performance of BGHE with PCM backfill have been undertaken. The results show that the heat exchange rate of the BGHE can be significantly enhanced by backfilling PCM with low and high phase change temperature for summer and winter modes, respectively. For improving energy storage effect and shortening soil thermal interference radius of the BGHE, a PCM with large latent heat should be used. During the alternate cooling and heating cycle, PCM backfill can reduce the peak value of soil temperature fluctuation and delay the recovery rate of soil temperature, and the daily total heat transfer amount of single borehole can be improved. Additionally, in order to balance soil temperature and PCM recovery, an optimal ratio of operation to recovery time should be found for a specific building. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 235
页数:20
相关论文
共 31 条
[1]  
ANSYS Fluent Inc, 2013, ANSYS Fluent Users Guide
[2]   Transient heat transfer in a U-tube borehole heat exchanger [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2014, 62 (01) :256-266
[3]   Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating [J].
Benli, Hueseyin ;
Durmus, Aydin .
ENERGY AND BUILDINGS, 2009, 41 (02) :220-228
[4]   Energetic performance analysis of a ground-source heat pump system with latent heat storage for a greenhouse heating [J].
Benli, Huseyin .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :581-589
[5]  
Bottarelli M, 2013, EUR GEOTH C 2013 IT, P3
[6]  
Bottarelli M., 2013, SUSTAINABLE ENERGY S
[7]   Heat transfer analysis of underground thermal energy storage in shallow trenches filled with encapsulated phase change materials [J].
Bottarelli, Michele ;
Bortoloni, Marco ;
Su, Yuehong .
APPLIED THERMAL ENGINEERING, 2015, 90 :1044-1051
[8]   Numerical analysis of a novel ground heat exchanger coupled with phase change materials [J].
Bottarelli, Michele ;
Bortoloni, Marco ;
Su, Yuehong ;
Yousif, Charles ;
Aydin, Ahmet Alper ;
Georgiev, Aleksandar .
APPLIED THERMAL ENGINEERING, 2015, 88 :369-375
[9]   Restoration performance and operation characteristics of a vertical U-tube ground source heat pump system with phase change grouts under different running modes [J].
Chen, Fei ;
Mao, Jinfeng ;
Li, Chaofeng ;
Hou, Pumin ;
Li, Yong ;
Xing, Zheli ;
Chen, Shangyuan .
APPLIED THERMAL ENGINEERING, 2018, 141 :467-482
[10]   Efficiency analysis of utilizing phase change materials as grout for a vertical U-tube heat exchanger coupled ground source heat pump system [J].
Chen, Fei ;
Mao, Jinfeng ;
Chen, Shangyuan ;
Li, Chaofeng ;
Hou, Pumin ;
Liao, Lu .
APPLIED THERMAL ENGINEERING, 2018, 130 :698-709