Electrocatalytic Oxidation of NADH Using a Pencil Graphite Electrode Modified with Hematoxylin

被引:14
作者
Dilgin, Yusuf [1 ]
Ertek, Bensu [1 ]
Kizilkaya, Bayram [2 ]
Dilgin, Didem Giray [3 ,4 ]
Gokcel, H. Ismet [4 ]
机构
[1] Canakkale Onsekiz Mart Univ, Sci & Art Fac, Dept Chem, TR-17100 Canakkale, Turkey
[2] Canakkale Onsekiz Mart Univ, Sci & Technol Applicat & Res Ctr, Cent Lab, TR-17100 Canakkale, Turkey
[3] Canakkale Onsekiz Mart Univ, Biga Vocat Coll, TR-17200 Biga, Canakkale, Turkey
[4] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
关键词
Electrocatalytic Oxidation; Hematoxylin; NADH; Pencil Graphite Electrode; CARBON-PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; PHOTOELECTROCATALYTIC OXIDATION; NANOTUBES; DNA; BIOSENSORS; REDOX; BLOOD; ACID;
D O I
10.1166/sam.2012.1376
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present study, the electrocatalytic oxidation of reduced p-Nicotinamide Adenine Dinucleotide (NADH) was investigated using a pencil graphite electrode modified with hematoxylin (PGE/HMT). The PGE/HMT was prepared by adsorption of HMT on the PGE via immersion of bare PGE into 1.0 mM HMT solution (in methanol) for 60 s at room temperature. Cyclic voltammetric studies show that the peak potential of NADH oxidation shifts from +450 mV at bare PGE to +200 mV at PGE/HMT. The electrocatalytic currents obtained from the amperometric measurements at +200 mV versus Ag/AgCl/KClsat and pH 7.0 phosphate buffer solution containing 0.1 M KCl were linearly related to the concentration of NADH. The calibration graph consisted of two linear segments of 0.5-10 mu M and 10-300 mu M with a detection limit of 0.2 mu M (based on 3s(b), s(b) is the standard deviation of the blank response). The amperometric measurements exhibited that the response of the modified PGE/HMT towards the oxidation of NADH is reproducible, fast, sensitive and stable. Finally, the results obtained in the present study conclusively show that PGE modified with HMT can be effectively used to detect NADH.
引用
收藏
页码:920 / 927
页数:8
相关论文
共 43 条
[1]   Photoelectrocatalytic oxidation of NADH in a flow injection analysis system using a poly-hematoxylin modified glassy carbon electrode [J].
Dilgin, Didem Giray ;
Gligor, Delia ;
Gokcel, H. Ismet ;
Dursun, Zekerya ;
Dilgin, Yusuf .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :411-417
[2]   Photoelectrocatalytic oxidation of NADH with electropolymerized Toluidine Blue O [J].
Dilgin, Yusuf ;
Gorton, Lo ;
Nisli, Gurel .
ELECTROANALYSIS, 2007, 19 (2-3) :286-293
[3]   Photoelectrocatalytic determination of NADH in a flow injection system with electropolymerized methylene blue [J].
Dilgin, Yusuf ;
Dilgin, Didem Giray ;
Dursun, Zekerya ;
Gokcel, H. Ismet ;
Gligor, Delia ;
Bayrak, Burcu ;
Ertek, Bensu .
ELECTROCHIMICA ACTA, 2011, 56 (03) :1138-1143
[4]   Poly-xanthurenic acid as an efficient mediator for the electrocatalytic oxidation of NADH [J].
dos Santos Silva, Francisco de Assis ;
Lopes, Cleylton Bezerra ;
Costa, Erivaldo de Oliveira ;
Lima, Phabyanno Rodrigues ;
Kubota, Lauro Tatsuo ;
Fonseca Goulart, Marilia Oliveira .
ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (03) :450-454
[5]   Electrochemical genomagnetic assay for the detection of hepatitis B virus DNA in polymerase chain reaction amplicons by using disposable sensor technology [J].
Erdem, A ;
Ariksoysal, DO ;
Karadeniz, H ;
Kara, P ;
Sengonul, A ;
Sayiner, AA ;
Ozsoz, M .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (08) :815-820
[6]   Differential pulse anodic voltammetric determination of pantoprazole in pharmaceutical dosage forms and human plasma using glassy carbon electrode [J].
Erk, N .
ANALYTICAL BIOCHEMISTRY, 2003, 323 (01) :48-53
[7]   Electrocatalytic activity of 6,7-dihydroxy-3-methyl-9-thia-4,4a-diazafluoren-2-one/multi-wall carbon nanotubes immobilized on carbon paste electrode for NADH oxidation: Application to the trace determination of NADH [J].
Fotouhi, Lida ;
Raei, Fatemeh ;
Heravi, Majid M. ;
Nematollahi, Davood .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) :15-20
[8]  
GORTON L, 1992, ACS SYM SER, V487, P56
[9]   CHEMICALLY MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC OXIDATION OF NICOTINAMIDE COENZYMES [J].
GORTON, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1245-1258
[10]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES BY GRAPHITE-ELECTRODES MODIFIED WITH AN ADSORBED PHENOXAZINIUM SALT, MELDOLA BLUE [J].
GORTON, L ;
TORSTENSSON, A ;
JAEGFELDT, H ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 161 (01) :103-120