On Phasor Measurement Unit Placement against State and Topology Attacks

被引:0
|
作者
Kim, Jinsub [1 ]
Tong, Lang [1 ]
机构
[1] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14850 USA
关键词
Power system cyber security; false data injection; topology attack; state estimation; phasor measurement units;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Cyber attacks on the SCADA system can mislead the control center to produce incorrect state and topology estimate. If undetected, state and topology attacks can have detrimental impacts on the real-time operation of a power system. The problem of placing secure phasor measurement units (PMUs) to detect such attacks is considered. It is shown that any state or topology attack is detectable if and only if buses with secure PMUs form a vertex cover of the system topology. This condition leads to the countermeasures constructed by available graph algorithms. The examples with IEEE 14-bus, 118-bus, and 300bus systems demonstrate applications of the countermeasures.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [1] Optimal placement of phasor measurement unit in distribution networks considering the changes in topology
    Su, Hongzhi
    Wang, Chengshan
    Li, Peng
    Liu, Zhelin
    Yu, Li
    Wu, Jianzhong
    APPLIED ENERGY, 2019, 250 : 313 - 322
  • [2] Phasor Measurement Unit Placement Algorithm
    Kulkarni, S.
    Allen, A.
    Santoso, S.
    Grady, W. M.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1347 - 1352
  • [3] Multistage Optimal Placement of Phasor Measurement Unit
    Shyam, Chaw Chuaong
    Rabha, Papu
    Sinha, Ashoke Kumar
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [4] the Method of Optimal Phasor Measurement Unit Placement
    Zhang Wen-jun
    Xu Jian-jun
    Xing Long
    ADVANCES IN APPLIED SCIENCE AND INDUSTRIAL TECHNOLOGY, PTS 1 AND 2, 2013, 798-799 : 298 - +
  • [5] Phasor measurement unit placement based on incomplete observability
    Nuqui, RF
    Phadke, AG
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 888 - 893
  • [6] A Brief Study on Optimal Placement of Phasor Measurement Unit
    Kaushal, Kajal
    Syal, Poonam
    Sinha, S. K.
    3RD INTERNATIONAL CONFERENCE ON INNOVATIVE APPLICATIONS OF COMPUTATIONAL INTELLIGENCE ON POWER, ENERGY AND CONTROLS WITH THEIR IMPACT ON HUMANITY (CIPECH-18), 2018, : 215 - 220
  • [7] An improved optimal phasor measurement unit placement algorithm
    Li, Qiang
    Yu, Er-Keng
    Lü, Shi-Chao
    Pan, Yi
    Zhou, Jing-Yang
    Power System Technology, 2005, 29 (12) : 57 - 61
  • [8] Participation factor approach for phasor measurement unit placement in power system state estimation
    Caro, E.
    Singh, R.
    Pal, B. C.
    Conejo, A. J.
    Jabr, R. A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (09) : 922 - 929
  • [9] Optimal Placement of Phasor Measurement Unit for Observation Reliability Enhancement
    Van-Khoi Tran
    Zhang, He-sheng
    Van-Nghia Nguyen
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 996 - 1006
  • [10] Optimal Phasor Measurement Unit Placement by an Improved PSO Algorithm
    Wang, Jian-ming
    Li Chuandong
    Zhang, Jian
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,