Retention projection enables accurate calculation of liquid chromatographic retention times across labs and methods

被引:37
作者
Abate-Pella, Daniel [1 ]
Freund, Dana M. [1 ]
Ma, Yan [2 ]
Simon-Manso, Yamil [3 ]
Hollender, Juliane [4 ]
Broeckling, Corey D. [5 ]
Huhman, David V. [6 ]
Krokhin, Oleg V. [7 ]
Stoll, Dwight R. [8 ]
Hegeman, Adrian D. [1 ]
Kind, Tobias [2 ]
Fiehn, Oliver [2 ,9 ]
Schymanski, Emma L. [4 ]
Prenni, Jessica E. [5 ]
Sumner, Lloyd W. [6 ]
Boswell, Paul G. [1 ]
机构
[1] Univ Minnesota, Dept Hort Sci, St Paul, MN 55108 USA
[2] Univ Calif Davis, UC Davis Genome Ctr, Metabol, Davis, CA 95616 USA
[3] NIST, Biomol Measurement Div, Gaithersburg, MD 20899 USA
[4] Eawag Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[5] Colorado State Univ, Prote & Metabol Facil, Ft Collins, CO 80523 USA
[6] Samuel Roberts Noble Fdn Inc, Ardmore, OK 73401 USA
[7] Univ Manitoba, Dept Internal Med, Winnipeg, MB R3E 3P4, Canada
[8] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[9] King Abdulaziz Univ, Dept Biochem, Jeddah 21413, Saudi Arabia
基金
美国国家科学基金会;
关键词
Retention projection; Retention prediction; Liquid chromatography-mass spectrometry; Retention library; Retention database; Multi-laboratory study; DIFFERENT GRADIENTS; COLUMN SELECTIVITY; INDEX SCALE; FLOW-RATES; PERFORMANCE; PHASE; TEMPERATURE; IDENTIFICATION; METABOLOMICS; MYCOTOXINS;
D O I
10.1016/j.chroma.2015.07.108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Identification of small molecules by liquid chromatography-mass spectrometry (LC-MS) can be greatly improved if the chromatographic retention information is used along with mass spectral information to narrow down the lists of candidates. Linear retention indexing remains the standard for sharing retention data across labs, but it is unreliable because it cannot properly account for differences in the experimental conditions used by various labs, even when the differences are relatively small and unintentional. On the other hand, an approach called "retention projection" properly accounts for many intentional differences in experimental conditions, and when combined with a "back-calculation" methodology described recently, it also accounts for unintentional differences. In this study, the accuracy of this methodology is compared with linear retention indexing across eight different labs. When each lab ran a test mixture under a range of multi-segment gradients and flow rates they selected independently, retention projections averaged 22-fold more accurate for uncharged compounds because they properly accounted for these intentional differences, which were more pronounced in steep gradients. When each lab ran the test mixture under nominally the same conditions, which is the ideal situation to reproduce linear retention indices, retention projections still averaged 2-fold more accurate because they properly accounted for many unintentional differences between the LC systems. To the best of our knowledge, this is the most successful study to date aiming to calculate (or even just to reproduce) LC gradient retention across labs, and it is the only study in which retention was reliably calculated under various multi-segment gradients and flow rates chosen independently by labs. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 41 条
[1]  
[Anonymous], CRC HDB CHEM PHYS
[2]   RETENTION INDEX SCALE FOR LIQUID-LIQUID CHROMATOGRAPHY [J].
BAKER, JK ;
MA, CY .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :107-115
[3]  
Baumann E., 1886, Ber. Dtsch. Chem. Ges, V19, P3218, DOI [10.1002/cber.188601902348, DOI 10.1002/CBER.188601902348]
[4]   IMPROVED STANDARDIZATION IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING 1-NITROALKANES AS A RETENTION INDEX SCALE [J].
BOGUSZ, M ;
ADERJAN, R .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :43-53
[5]   Comparability of RP-HPLC retention indices of drugs in three databases [J].
Bogusz, M ;
Hill, DW ;
Rehorek, A .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (08) :1291-1316
[6]   CORRECTED RETENTION INDEXES IN HPLC - THEIR USE FOR THE IDENTIFICATION OF ACIDIC AND NEUTRAL-DRUGS [J].
BOGUSZ, M ;
ADERJAN, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (02) :67-72
[7]   Calculation of retention time tolerance windows with absolute confidence from shared liquid chromatographic retention data [J].
Boswell, Paul G. ;
Abate-Pella, Daniel ;
Hewitt, Joshua T. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1412 :52-58
[8]   A study on retention "projection" as a supplementary means for compound identification by liquid chromatography-mass spectrometry capable of predicting retention with different gradients, flow rates, and instruments [J].
Boswell, Paul G. ;
Schellenberg, Jonathan R. ;
Carr, Peter W. ;
Cohen, Jerry D. ;
Hegeman, Adrian D. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) :6732-6741
[9]   Easy and accurate high-performance liquid chromatography retention prediction with different gradients, flow rates, and instruments by back-calculation of gradient and flow rate profiles [J].
Boswell, Paul G. ;
Schellenberg, Jonathan R. ;
Carr, Peter W. ;
Cohen, Jerry D. ;
Hegeman, Adrian D. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) :6742-6749
[10]  
Cao M., 2014, METABOLOMICS, P1