Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench

被引:150
作者
Gatinel, Damien [1 ,2 ]
Houbrechts, Yvette [3 ]
机构
[1] Fdn Ophtalmol Adolphe de Rothschild, F-75940 Paris 19, France
[2] Ctr Expertise & Res Opt Clinicians, Paris, France
[3] Univ Liege, Ctr Spatial Liege, Liege, Belgium
关键词
EYE MODEL; PERFORMANCE; QUALITY; IMAGE; DISTANCE;
D O I
10.1016/j.jcrs.2013.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons. SETTING: Rothschild Foundation, Paris, France. DESIGN: Experimental study. METHODS: Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, Tecnis ZM900, and Rezoom, Diffractiva Diff-s, and Lentis Mplus +3.0 D) were tested using the same optical bench that complies with International Organization for Standardization standard 11979 requirements. The through-focus modulation transfer functions (MTFs) were compared, and the image of the United States Air Force (USAF) target was taken while each IOL was at far, intermediate, and near focal points. RESULTS: The through-focus MTF of the trifocal IOL showed a peak in the intermediate range that was not present with monofocal and bifocal IOLs. The USAF target images showed similar resolution with all IOLs for far focal points. Diffractive IOLs showed better resolution for near focal points, and the only sharp image in the intermediate range was obtained using the trifocal IOL. CONCLUSION: There was a significant difference in the degree of near, intermediate, and distance quality of the image with the various types of multifocal IOLs in vitro. Intermediate vision was more prominent with the trifocal IOL. (C) 2013 ASCRS and ESCRS
引用
收藏
页码:1093 / 1099
页数:7
相关论文
共 19 条
[1]   Intermediate visual function with different multifocal intraocular lens models [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Puchades, Cristina ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) :733-739
[2]   Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Plaza-Puche, Ana B. ;
Joanna Rodriguez, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :241-250
[3]   Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs [J].
Artigas, Jose M. ;
Menezo, Jose L. ;
Peris, Cristina ;
Felipe, Adelina ;
Diaz-Llopis, Manuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2111-2117
[4]   Visual and refractive outcomes after implantation of a fully diffractive trifocal lens [J].
Cochener, Beatrice ;
Vryghem, Jerome ;
Rozot, Pascal ;
Lesieur, Gilles ;
Heireman, Steven ;
Blanckaert, Johan A. ;
Van Acker, Emmanuel ;
Ghekiere, Sofie .
CLINICAL OPHTHALMOLOGY, 2012, 6 :1421-1427
[5]   Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery [J].
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Montes-Mico, Robert ;
Tahzib, Nayyirih G. ;
Cheng, Yanny Y. Y. ;
de Brabander, Johri ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1476-1482
[6]   Design and qualification of a diffractive trifocal optical profile for intraocular lenses [J].
Gatinel, Damien ;
Pagnoulle, Christophe ;
Houbrechts, Yvette ;
Gobin, Laure .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) :2060-2067
[7]   Far and near visual acuity with multifocal intraocular lenses in an optomechanical eye model with imaging capability [J].
Gobbi, Pier Giorgio ;
Fasce, Francesco ;
Bozza, Stefano ;
Calori, Giliola ;
Brancato, Rosario .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06) :1082-1094
[8]   Quality of Image of Grating Target Placed in Model of Human Eye With Corneal Aberrations as Observed Through Multifocal Intraocular Lenses [J].
Inoue, Makoto ;
Noda, Toru ;
Mihashi, Toshifumi ;
Ohnuma, Kazuhiko ;
Bissen-Miyajima, Hiroko ;
Hirakata, Akito .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (04) :644-652
[9]  
International Organization for Standardization, 2006, 119799 ISO
[10]  
International Organization for Standardization, 1999, 119792 ISO