Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula

被引:169
作者
Haigis, Wolfgang [1 ]
机构
[1] Univ Eye Hosp, D-97080 Wurzburg, Germany
关键词
D O I
10.1016/j.jcrs.2008.06.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe the Haigis-L formula for the calculation of intraocular lenses (IOLs) after refractive laser surgery for myopia based on current biometry and keratometry and present clinical results. SETTING: University Eye Hospital, Wuerzburg, Germany, and various clinics and private practices METHODS: The basic concepts of the new algorithm were described and summarized. The Haigis formula was analyzed with respect to its usability for eyes after laser surgery for myopia and modified accordingly. Correction curves for IOLMaster keratometry were derived from previous studies. The new formula was checked using the postoperative results of 187 cataract procedures in which 32 IOL types were implanted by 57 surgeons. Input data were current IOLMaster biometry as follows: axial length (AL), anterior chamber depth (ACD), and keratometry (corneal radii) measurements. RESULTS: Before IOL surgery, the mean spherical equivalent was -7.60 diopters (D) +/- 3.90 (SD) (range -20.00 to -1.25 D); the mean AL, 27.02 +/- 2.01 mm (range 23.09 to 35.32 mm); the mean ACD, 3.52 +/- 0.36 mm (range 2.43 to 4.39 mm); and the mean of the measured corneal radii, 8.70 +/- 0.60 mm (range 7.28 to 10.96 mm). The mean arithmetic refractive prediction error was -0.04 +/- 0.70 D (range -2.30 to +/- 2.40 D) and the median absolute error, 0.37 D (range +/- 0.01 to +/- 2.40 D). The percentages of correct refraction predictions within +/- 2.00, +/- 1.00, and +/- 0.50 D were 98.4%, 84.0%, and 61.0%, respectively. CONCLUSIONS: The new formula would produce promising results in eyes without refractive history. Its refractive predictability fulfills the current criteria for normal eyes.
引用
收藏
页码:1658 / 1663
页数:6
相关论文
共 24 条
[1]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[2]   Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula [J].
Borasio, Edmondo ;
Stevens, Julian ;
Smith, Guy T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2004-2014
[3]  
Einighammer J, 2007, J REFRACT SURG, V23, P393
[4]  
GALE RP, 2008, EYE IN PRESS
[5]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[6]  
Haigis W., 2004, Intraocular Lens Power Calculations, P41
[7]  
HAIGIS W, 2006, OPHTHALMO CHIRURGIE, V18, P27
[8]  
HAIGIS W, 2003, OPHTHALMO CHIRURG, V15, P193
[9]   Preoperative intraocular lens power calculations in problem eyes [J].
Haigis, Wolfgang .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2007, 17 (01) :45-54
[10]  
HOFFER KJ, 1995, J REFRACT SURG, V11, P490