Factor Analysis on Criteria Affecting Lean Retrofit for Energy Efficient Initiatives in Higher Learning Institution Buildings

被引:2
作者
Abidin, Nur IzieAdiana [1 ]
Zakaria, Rozana [1 ]
Aminuddin, Eeydzah [1 ]
Hamid, Abdul Rahim Abdul [1 ]
Munikanan, Vikneswaran [2 ]
Sahamir, Shaza Rina [3 ]
Shamsuddin, Siti Mazzuana [3 ]
机构
[1] Univ Teknol Malaysia, Fac Civil Engn, Johor Baharu, Malaysia
[2] Univ Pertahanan Malaysia, Fac Engn, Kuala Lumpur, Malaysia
[3] Univ Teknol Mara, Fac Architecture Planning & Surveying, Shah Alam, Selangor, Malaysia
来源
6TH INTERNATIONAL CONFERENCE OF EURO ASIA CIVIL ENGINEERING FORUM (EACEF 2017) | 2017年 / 138卷
关键词
RESIDENTIAL BUILDINGS; UNIVERSITY CAMPUS; CONSUMPTION; DESIGN; SUSTAINABILITY; CONSERVATION; COST;
D O I
10.1051/matecconf/201713802025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The expansion of Higher Learning Institution (HLI) is a global concerns on energy demand due to campus act like a small city. Intensive mode of operation of a building is correlated to the energy utilization. Improvement in the current energy efficiency is crucial effort to minimize the environmental effect through minimisation of energy in operation by retrofitting and upgrade the existing building system or components to be more efficient. Basically, there are three recommended steps for the improvement known as lean initiatives, green technology and clean energy in response to becoming zero energy solutions for building. The deliberation of this paper is aimed to highlight the criteria affecting in retrofitting of existing building in HLI with lean initiatives in order to achieve energy efficiency and reduction of energy comsumption. Attention is devoted to reviewing the lean energy retrofitting initiatives criteria for daylighting (side lighting), daylighting (skylight) and glazing. The questionnaire survey was employed and distributed to the architects who has an expertise in green building design. Factor analysis was adopted as a method of analysis by using Principal Component with Varimax Rotation. The result is presented through summarizing the sub-criteria according to its importance with a factor loading 0.50 and above. The result found that majority of the criteria developed achieved the significant factor loading value and in accordance with the protocal of analysis. In conclusion the results from analysis of this paper assists the stakeholders in assessing the significant criteria based on the desired lean energy retrofitting initiatives and also provides a huge contribution for future planning improvement in existing buildings to become an energy efficient building.
引用
收藏
页数:10
相关论文
共 38 条
[1]   An integrated approach to achieving campus sustainability: assessment of the current campus environmental management practices [J].
Alshuwaikhat, Habib M. ;
Abubakar, Ismaila .
JOURNAL OF CLEANER PRODUCTION, 2008, 16 (16) :1777-1785
[2]  
Appleby Paul., 2013, Sustainable Retrofit and Facilities Management
[3]  
Ayala E, 2011, ENERGY EFFICIENT MET, P235
[4]   Daylight factor prediction in atria building designs [J].
Calcagni, B ;
Paroncini, M .
SOLAR ENERGY, 2004, 76 (06) :669-682
[5]  
Chee Yue J. L, 2014, OTTV CALCULATION ENE
[6]   Potential opportunities for energy conservation in existing buildings on university campus: A field survey in Korea [J].
Chung, Min Hee ;
Rhee, Eon Ku .
ENERGY AND BUILDINGS, 2014, 78 :176-182
[7]  
Citterio M., 2003, RETROFIT U BUILDING
[8]  
College of Desert, 2011, COLL DES CAMP WID LI
[9]  
Danby D, 2011, PASSIVE DESIGN STRAT
[10]   Energy efficiency and the environment: the potential for energy efficient lighting to save energy and reduce carbon dioxide emissions at Melbourne University, Australia [J].
Di Stefano, J .