Stent modeling using immersed finite element method

被引:38
作者
Gay, Mickael
Zhang, Lucy
Liu, Wing Kam
机构
[1] Tulane Univ, Dept Mech Engn, New Orleans, LA 70118 USA
[2] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
基金
美国国家科学基金会;
关键词
immersed finite element method; fluid-structure interactions; balloon angioplasty; angioplasty stent;
D O I
10.1016/j.cma.2005.09.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this paper is to study the mechanical behaviors of angioplasty stents during and after implantation using a fluid-structure interaction computational technique. The deployment of a balloon expandable stent is simulated using immersed finite element method (IFEM), which was developed for solving complex fluid and deformable structure interaction problems. Using this method, we modelled a stainless steel stent in a blood vessel. A balloon is deployed to assist the expansion of the stent that is to be plastically deformed. The balloon is modelled as a thin hyperelastic material while the stent has the property of steel. The mechanical behaviors such as the expansion mechanism, stress distribution on the stent, and the surrounding fluid velocity profile during the implantation of the stent are studied. With appropriate applied internal pressure, the balloon inside the stent is deployed which linearly expands the diameter of a Medtronic AVE Modular Stent S7 until it reaches 1.7 times of its original diameter. The results will assist in the development of novel stent designs and stent deployment protocols to minimize vascular injury during stenting and reduce restenosis. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:4358 / 4370
页数:13
相关论文
共 32 条
[1]  
Belytschko T., 2013, NONLINEAR FINITE ELE
[2]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[3]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[4]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075
[5]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]   BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS [J].
GOLDBERG, SL ;
COLOMBO, A ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :996-1003
[7]   Restenosis - An open file [J].
GottsaunerWolf, M ;
Moliterno, DJ ;
Lincoff, AM ;
Topol, EJ .
CLINICAL CARDIOLOGY, 1996, 19 (05) :347-356
[8]  
HOLZAPFEL GA, 2000, MECH BIOL, V46, P141
[9]  
IRIMPEN A, COMMUNICATION
[10]   Immersed interface methods for Stokes flow with elastic boundaries or surface tension [J].
Leveque, RJ ;
Li, ZL .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1997, 18 (03) :709-735