Highly adhesive, washable and stretchable on-skin electrodes based on polydopamine and silk fibroin for ambulatory electrocardiography sensing

被引:25
作者
Du, Xiaohui [1 ,2 ]
Niu, Zhikai [1 ,2 ]
Li, Rongjin [1 ,2 ]
Yang, Hui [1 ,2 ]
Hu, Wenping [1 ,2 ,3 ,4 ]
机构
[1] Tianjin Univ, Sch Sci, Dept Chem, Tianjin Key Lab Mol Optoelect Sci, Tianjin 300072, Peoples R China
[2] Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300072, Peoples R China
[3] Natl Univ Singapore, Joint Sch, Singapore, Singapore
[4] Tianjin Univ, Fuzhou Int Campus, Fuzhou 350207, Peoples R China
基金
中国国家自然科学基金;
关键词
CORONARY HEART-DISEASE; POLYMERIZATION; ARRHYTHMIAS; ECG;
D O I
10.1039/d0tc01940b
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ambulatory electrocardiography (ECG) is used to realize the diagnostics of coronary heart disease. On-skin electrodes are employed for ambulatory ECG sensing through conformable contact with the arbitrarily shaped moving skin. However, the low skin-adhesion of electrodes limits their application in long-term ambulatory ECG sensing. For example, for the current on-skin electrodes, the low shear viscosity of sweat on the skin decreases the skin-adhesion, leading to their slipping and even falling off. Herein, highly adhesive and washable on-skin electrodes were achieved by combining stretchable Au nanofilms with hybrid materials composed of polydopamine and silk fibroin (SF). The strong interaction of polydopamine with water enhanced the adhesion energy of these electrodes by decreasing the Young's modulus of the SF gel and increasing the contact area between electrodes and skin. Additionally, the microcrack structure of Au nanofilms provided good conductivity upon stretching. Remarkably, our electrodes could be easily removed on washing and had low impedance due to the existence of hydrophilic SF and Ca2+. To demonstrate the application of these electrodes for perceiving accurate and reliable signals, they were pasted on the skin to record long-term and high-quality ECG signals for the diagnosis of heart disease.
引用
收藏
页码:12257 / 12264
页数:8
相关论文
共 41 条
[1]  
[Anonymous], 2019, ORGAN RES METHODS, DOI DOI 10.1177/1094428116681072
[2]   Flexible polymeric dry electrodes for the long-term monitoring of ECG [J].
Baek, Ju-Yeoul ;
An, Jin-Hee ;
Choi, Jong-Min ;
Park, Kwang-Suk ;
Lee, Sang-Hoon .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) :423-429
[3]  
BETHGE KP, 1977, Z KARDIOL, V66, P1
[4]   Heart rate variability: Linear and non-linear analysis of pre-awake period for normal and intrauterine growth restricted children at 10 year [J].
Biala, Taher ;
Aziz, Wajid ;
Wailoo, Michael ;
Schlindwein, Fernando S. .
MEASUREMENT, 2012, 45 (08) :2096-2102
[5]   USE OF R-R INTERVAL AND DIFFERENCE HISTOGRAMS IN CLASSIFYING DISORDERS OF SINUS RHYTHM [J].
CASHMAN, PMM .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1977, 1 (01) :20-28
[6]   Plasticizing Silk Protein for On-Skin Stretchable Electrodes [J].
Chen, Geng ;
Matsuhisa, Naoji ;
Liu, Zhiyuan ;
Qi, Dianpeng ;
Cai, Pingqiang ;
Jiang, Ying ;
Wan, Changjin ;
Cui, Yajing ;
Leow, Wan Ru ;
Liu, Zhuangjian ;
Gong, Suxuan ;
Zhang, Ke-Qin ;
Cheng, Yuan ;
Chen, Xiaodong .
ADVANCED MATERIALS, 2018, 30 (21)
[7]   Bioinspired Composite Microfibers for Skin Adhesion and Signal Amplification of Wearable Sensors [J].
Drotlef, Dirk-M. ;
Amjadi, Morteza ;
Yunusa, Muhammad ;
Sitti, Metin .
ADVANCED MATERIALS, 2017, 29 (28)
[8]   Correlation of the β-sheet crystal size in silk fibers with the protein amino acid sequence [J].
Drummy, Lawrence F. ;
Farmer, B. L. ;
Naik, Rajesh R. .
SOFT MATTER, 2007, 3 (07) :877-882
[9]   Cardiac arrhythmias imprint specific signatures on Lorenz plots [J].
Esperer, Hans D. ;
Esperer, Chris ;
Cohen, Richard J. .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2008, 13 (01) :44-60
[10]   Comparison of methods for the assessment of nonlinearity in short-term heart rate variability under different physiopathological states [J].
Faes, Luca ;
Gomez-Extremera, Manuel ;
Pernice, Riccardo ;
Carpena, Pedro ;
Nollo, Giandomenico ;
Porta, Alberto ;
Bernaola-Galvan, Pedro .
CHAOS, 2019, 29 (12)