Frontal analysis of drug-plasma lipoprotein binding using capillary electrophoresis

被引:30
|
作者
Ohnishi, T
Mohamed, NAL
Shibukawa, A [1 ]
Kuroda, Y
Nakagawa, T
El Gizawy, S
Askal, HF
El Kommos, ME
机构
[1] Kyoto Univ, Grad Sch Pharmaceut Sci, Sakyo Ku, Kyoto 6068501, Japan
[2] Asiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Asiut, Egypt
关键词
capillary electrophoresis; frontal analysis; protein binding; lipoprotein; propranolol; enantiomer;
D O I
10.1016/S0731-7085(01)00569-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High performance frontal analysis coupled with capillary electrophoresis (HPFA/CE) was applied to the ultramicroanalysis of enantioselective binding of drug to plasma lipoproteins. A small volume (ca. 80 nl) of (R)- or (S)-propranolol (PRO, 25-150 muM) and human high-density lipoprotein (HDL, 2.63 g/l) or human low-density lipoprotein (LDL, 4.37 g/l) mixed solution, which was in the state of binding equilibrium, was introduced hydrodynamically into a non-coated fused silica capillary. Positively charged unbound PRO enantiomers migrated toward cathodic end much faster than negatively charged lipoproteins and the bound form. Once unbound PRO migrated apart from lipoprotein, the bound PRO was quickly released from the lipoprotein to maintain the binding equilibrium. Thus, PRO migrated as a zone in the capillary, giving a peak with a plateau region, where the concentration is the same as the unbound PRO concentration in the original sample solution. The unbound PRO concentration calculated form the plateau height agreed with that determined by a conventional ultrafiltration method used as a reference method. It was found that the bindings of PRO to HDL and PRO to LDL were not enantioselective, while the total binding affinity of PRO to LDL (4.01 x 10(5) per M) was 17 times higher than that of PRO-HDL binding (2.38 x 10(4) per M). (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 50 条
  • [41] CAPILLARY MODIFICATION AND EVALUATION USING STREAMING POTENTIAL AND FRONTAL CHROMATOGRAPHY FOR PROTEIN-ANALYSIS IN CAPILLARY ELECTROPHORESIS
    WANG, TS
    HARTWICK, RA
    JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2): : 325 - 334
  • [42] CAPILLARY ELECTROPHORESIS AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY IN DRUG AND METABOLITE ANALYSIS
    NAYLOR, S
    TOMLINSON, AJ
    BENSON, LM
    GORROD, JW
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1994, 19 (03) : 235 - 240
  • [43] Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
    Mlcochova, Hana
    Ratih, Ratih
    Michalcova, Lenka
    Watzig, Hermann
    Glatz, Zdenek
    Stein, Matthias
    ELECTROPHORESIS, 2022, 43 (16-17) : 1724 - 1734
  • [44] Improved capillary electrophoresis frontal analysis by dynamically coating the capillary with polyelectrolyte multilayers
    Liu, Chao
    Kang, Jingwu
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1238 : 146 - 151
  • [45] Using capillary electrophoresis frontal analysis to screen drugs interacting with human serum proteins
    McDonnell, PA
    Caldwell, GW
    Masucci, JA
    ELECTROPHORESIS, 1998, 19 (03) : 448 - 454
  • [46] Binding of bovine serum albumin to heparin determined by turbidimetric titration and frontal analysis continuous capillary electrophoresis
    Hattori, T
    Kimura, K
    Seyrek, E
    Dubin, PL
    ANALYTICAL BIOCHEMISTRY, 2001, 295 (02) : 158 - 167
  • [47] Specific Binding Constant and Stoichiometry Determination in Free Solution by Mass Spectrometry and Capillary Electrophoresis Frontal Analysis
    Qian, Cheng
    Fu, Hengqing
    Kovalchik, Kevin A.
    Li, Huihui
    Chen, David Da Yong
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 9483 - 9490
  • [48] Cooperative binding of nonionic surfactant to hydrophobically modified polyanions as studied by frontal analysis continuous capillary electrophoresis
    Hashidzume, Akihito
    Watanabe, Shin-ichi
    Morishima, Yotaro
    LANGMUIR, 2007, 23 (04) : 2191 - 2197
  • [49] Study of nobiletin binding to bovine serum albumin by capillary electrophoresis-frontal analysis and circular dichroism
    Yi, Lian
    Li, Hailing
    Deng, Qingqing
    Yuan, Zhongzheng
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 1023 - 1028
  • [50] Mobility-based correction for accurate determination of binding constants by capillary electrophoresis-frontal analysis
    Qian, Cheng
    Kovalchik, Kevin A.
    MacLennan, Matthew S.
    Huang, Xiaohua
    Chen, David D. Y.
    ELECTROPHORESIS, 2017, 38 (12) : 1572 - 1581