THE INFLUENCE OF POST ANGIOPLASTY STENT IMPLANT PROFILE ON ARTERIAL WALL STRESS

被引:0
|
作者
Teodorescu, Mircea [1 ]
Brand, Moshe [1 ]
Rosen, Jacob [1 ]
Rahnejat, Homer [1 ]
机构
[1] Cranfield Univ, Sch Engn, Bedford MK43 0BS, England
来源
PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, DETC 2010, VOL 4 | 2010年
关键词
CONTACT MECHANICS; RESTENOSIS; MODEL;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
One of the main causes for post angioplasty arterial restenosis is the excessive stress induced in the arterial wall during and after the medical intervention. The closed stent is introduced in the artery wrapped around the deflated balloon catheter and is expanded in the final position by inflating the balloon. Unfortunately, this process also stretches the arterial wall. Additionally, for the stent to be successful, its diameter must be slightly larger than the diameter of the inflated artery. The stent is usually a dense mesh of interconnected beams. Therefore, it is often considered that it applies a constant pressure to the artery / stent interface. However, in reality each beam individually presses against the innermost layer of the artery (intima). The current study proposes a model, which predicts the arterial wall subsurface stress field due to individual stent beams. It was found that the local shape of the contact (beam cross section) plays an important role close to the stent / intima contact. Sharper edged cross sections (e.g. square) promote higher stresses. It was observed that during restenosis a new inner layer (neointima) is formed, significantly reducing the stent efficiency. This could be related to local stress concentrations due to the choice of stent beam profile.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 50 条
  • [11] Protected stent-assisted carotid angioplasty in the management of late post-endarterectomy restenosis
    Cohen, JE
    Gomori, JA
    Rajz, G
    Ben-Hur, T
    Umansky, F
    NEUROLOGICAL RESEARCH, 2005, 27 : S64 - S68
  • [12] UTILIZING STENT WALL SHEAR STRESS TO ASSESS STENT AND FLOW DIVERTER PERFORMANCE FOR TREATING INTRACRANIAL ANEURYSMS
    Suess, Taylor N.
    Gent, Stephen P.
    PROCEEDINGS OF ASME 2022 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2022, VOL 4, 2022,
  • [13] Mechanical thrombectomy injury to the arterial wall: A comparison between catheter aspiration and stent retriever
    He, Guangchen
    Deng, Jiangshan
    Zhang, Yiran
    Lu, Haitao
    Zhao, Yuwu
    Yan, Lei
    Zhu, Yueqi
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139
  • [15] Modelling of stent expansion dynamics and resultant arterial wall and lesion stresses in a stenosed artery
    Hyre, M. R.
    Chae, S. A.
    Pulliam, R. M.
    DESIGN AND NATURE VI: COMPARING DESIGN IN NATURE WITH SCIENCE AND ENGINEERING, 2012, 160 : 195 - 209
  • [16] Numerical Simulation of Stent Angioplasty with Predilation: An Investigation into Lesion Constitutive Representation and Calcification Influence
    Conway, C.
    McGarry, J. P.
    Edelman, E. R.
    McHugh, P. E.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (09) : 2244 - 2252
  • [17] Increased artery wall stress post-stenting leads to greater intimal thickening
    Timmins, Lucas H.
    Miller, Matthew W.
    Clubb, Fred J., Jr.
    Moore, James E., Jr.
    LABORATORY INVESTIGATION, 2011, 91 (06) : 955 - 967
  • [18] Temporal Correlation between Wall Shear Stress and In-Stent Stenosis after Wingspan Stent in Swine Model
    Fujimoto, M.
    Takao, H.
    Suzuki, T.
    Shobayashi, Y.
    Mayor, F.
    Tateshima, S.
    Yamamoto, M.
    Murayama, Y.
    Vinuela, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (05) : 994 - 998
  • [19] A novel technique towards investigating wall shear stress within the stent struts using particle image velocimetry
    Freidoonimehr, Navid
    Arjomandi, Maziar
    Zander, Anthony
    Chin, Rey
    EXPERIMENTS IN FLUIDS, 2021, 62 (06)
  • [20] Rupture of the arterial wall causes deflection in pressure time course during ex vivo balloon angioplasty
    Steenhuijsen, JLG
    Vaartjes, SR
    Poortermans, CJ
    Havenith, MG
    Boom, HBK
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 42 (01): : 92 - 101