A comparison of two techniques for center of pressure measurements

被引:14
作者
DeBerardinis, Jessica [1 ]
Neilsen, Conner [1 ]
Lidstone, Daniel E. [2 ]
Dufek, Janet S. [2 ]
Trabia, Mohamed B. [1 ]
机构
[1] Univ Nevada, Dept Mech Engn, Las Vegas, NV 89154 USA
[2] Univ Nevada, Dept Kinesiol & Nutr Sci, Las Vegas, NV 89154 USA
关键词
Force platforms; pressure-measuring insoles; processing methods; gait analysis; center of pressure; GAIT; BALANCE; RELIABILITY; TREADMILL; INSOLES; WALKING;
D O I
10.1177/2055668320921063
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Force platforms and pressure-measuring insoles are the most common tools used for measuring center of pressure. Earlier studies to assess these instruments suffered from limited sample sizes or an inadequate range of participant foot sizes. The purpose of this study was to propose new methods to extract and calculate comparably accurate center of pressure for the Kistler (R) force platform and Medilogic (R) insoles. Methods: Center of pressure data were collected from 65 participants wearing pressure-measuring insoles (six different sizes). Participants walked over consecutive force platforms for three trials while wearing pressure-measuring insoles within socks. Onset force thresholds and center of pressure segment length thresholds were used to determine accurate center of pressure path length and width. A single step for each foot and trial was extracted from both instruments. Results: A strong correlation was observed between instruments in center of pressure length (4.12 +/- 6.72% difference, r = 0.74). Center of pressure width varied and was weakly correlated (-7.04 +/- 4.48% difference, r = 0.11). Conclusions: The results indicate that both instruments can measure center of pressure path length consistently and with comparable accuracy (differences < 10%). There were differences between instruments in measuring center of pressure path width, which were attributed to the limited number of sensors across the width of the insoles.
引用
收藏
页数:12
相关论文
共 33 条
[1]  
Anonymous, 1999, MOCNESS OP MAINT INS, P1
[2]  
Bartlett R., 2007, Introduction to Sports Biomechanics: Analysing Human Movement Patterns, V2nd
[3]   Postural sway and active balance performance in highly active lower-limb amputees [J].
Buckley, JG ;
O'Driscoll, D ;
Bennett, SJ .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (01) :13-20
[4]   Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements [J].
Chesnin, KJ ;
Selby-Silverstein, L ;
Besser, MP .
GAIT & POSTURE, 2000, 12 (02) :128-133
[5]  
Chumanov ES, 2007, P 30 ANN M AM SOC BI, P1
[6]  
Debbi Eytan M, 2012, Foot (Edinb), V22, P269, DOI 10.1016/j.foot.2012.07.001
[7]   Assessing the validity of pressure-measuring insoles in quantifying gait variables [J].
DeBerardinis, Jessica ;
Dufek, Janet S. ;
Trabia, Mohamed B. ;
Lidstone, Daniel E. .
JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2018, 5
[8]   Effect of prosthetic design on center of pressure excursion in partial foot prostheses [J].
Dillon, Michael P. ;
Fatone, Stefania ;
Hansen, Andrew H. .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (02) :161-177
[9]   Diabetic peripheral neuropathy and its evaluation in a clinical scenario: A review [J].
Dixit, S. ;
Maiya, A. .
JOURNAL OF POSTGRADUATE MEDICINE, 2014, 60 (01) :33-40
[10]   Use of pressure insoles to calculate the complete ground reaction forces [J].
Forner Cordero, A ;
Koopman, HJFM ;
van der Helm, FCT .
JOURNAL OF BIOMECHANICS, 2004, 37 (09) :1427-1432