Dynamic Simulation of a Trigeneration Scheme for Domestic Purposes Based on Hybrid Techniques

被引:19
作者
Acevedo, Luis [1 ]
Uche, Javier [1 ]
Del Almo, Alejandro [2 ]
Cirez, Fernando [1 ]
Uson, Sergio [1 ]
Martinez, Amaya [1 ]
Guedea, Isabel [2 ]
机构
[1] Univ Zaragoza, Res Ctr Energy Resources & Consumpt CIRCE, Circe Bldg 15,Mariano Esquillor Gomez St, Zaragoza 50018, Spain
[2] ENDEF Co, Poligono Ind Ciudad Transporte, 11 P-A St, Zaragoza 50820, Spain
关键词
dynamic simulations; photovoltaic/thermal (PVT); wind turbine (WT); membrane distillation (MD); reverse osmosis (RO); hybrid systems; TRNSYS (R); MEMBRANE DISTILLATION; DESALINATION; ENERGY; DESIGN; POWER; OPTIMIZATION; PERFORMANCE; SYSTEMS; MODEL; GAS;
D O I
10.3390/en9121013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the design of a system providing electricity by coupling photovoltaic/thermal (PVT) collectors and a wind turbine (WT), sanitary hot water (SHW) coming from the PVT and evacuated tube collectors (ETCs) and fresh water (FW) produced in two seawater desalting facilities (membrane distillation, MD, and reverse osmosis, RO), has been carefully analyzed by means of a dynamic model developed in TRNSYS (R). This analysis is compulsory to operate a lab-scale pilot plant that is being erected at Zaragoza, Spain. A new model-type has been included in TRNSYS (R) in order to include the MD unit in the scheme. A sensitivity analysis of some free-design variables, such that the ETC surface, PVT and ETC tilt, water storage tank, batteries capacities, and mass flow rates delivered to the SHW service and/or feeding the MD unit has been performed in order to propose the definite design of the scheme. The proposed base case was able to produce up to 15,311 L per year in the MD system and cover an electric energy demand of 1890 kWh. Coverage of SHW, water (including RO and MD) and power is respectively 99.3%, 100% and 70%. However, daily and yearly assessment of FW, SHW and power produced with the optimized design gave a better coverage of water and energy demands for a typical single family home. The improved and definite design was able to increase its MD production in 35% and the electric energy in 7% compared with base case.
引用
收藏
页数:25
相关论文
共 47 条
[1]   Experimental Validation of Forced Circulation of Solar Water Heating Systems in TRNSYS [J].
Abdunnabi, M. J. R. ;
Alakder, K. M. A. ;
Alkishriwi, N. A. ;
Abughres, S. M. .
2013 ISES SOLAR WORLD CONGRESS, 2014, 57 :2477-+
[2]   Design and experimental performance of brackish water reverse osmosis desalination unit powered by 2 kW photovoltaic system [J].
Alghoul, M. A. ;
Poovanaesvaran, P. ;
Mohammed, M. H. ;
Fadhil, A. M. ;
Muftah, A. F. ;
Alkilani, M. M. ;
Sopian, K. .
RENEWABLE ENERGY, 2016, 93 :101-114
[3]  
[Anonymous], 2007, TRNSYS MATH REF
[4]  
[Anonymous], 2010, TRNSYS TRANS SYST SI, V16
[5]   Design, modeling and performance monitoring of a photovoltaic-thermal (PVT) water collector [J].
Aste, Niccolo ;
Leonforte, Fabrizio ;
Del Pero, Claudio .
SOLAR ENERGY, 2015, 112 :85-99
[6]   Optimization of solar thermal fraction in PVT systems [J].
Aste, Niccolo ;
Del Pero, Claudio ;
Leonforte, Fabrizio .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :8-18
[7]   Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors [J].
Ayompe, L. M. ;
Duffy, A. ;
McCormack, S. J. ;
Conlon, M. .
APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) :1536-1542
[8]   Dynamical simulation of PV/Wind hybrid energy conversion system [J].
Bakic, Vukman ;
Pezo, Milada ;
Stevanovic, Zana ;
Zivkovic, Marija ;
Grubor, Borislav .
ENERGY, 2012, 45 (01) :324-328
[9]   Design, Simulation and Experimental Investigation of a Solar System Based on PV Panels and PVT Collectors [J].
Buonomano, Annamaria ;
Calise, Francesco ;
Vicidomini, Maria .
ENERGIES, 2016, 9 (07)
[10]   Thermoeconomic Optimization of a Renewable Polygeneration System Serving a Small Isolated Community [J].
Calise, Francesco ;
d'Accadia, Massimo Dentice ;
Piacentino, Antonio ;
Vicidomini, Maria .
ENERGIES, 2015, 8 (02) :995-1024