Highly Stable Polymeric Ionic Liquid Modified Electrode to Immobilize Ferricyanide for Electroanalysis of Sulfide

被引:18
作者
Chang, Jen-Lin [1 ]
Wei, Guor-Tzo [2 ]
Chen, Tsu-Yin [1 ]
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
[2] Natl Chung Cheng Univ, Dept Chem & Biochem, Chiayi 62102, Taiwan
关键词
Room temperature ionic liquid (RTIL); Screen-printed carbon electrode (SPCE); Sulfide; Ferricyanide; SCREEN-PRINTED ELECTRODE; FLOW-INJECTION ANALYSIS; AMPEROMETRIC DETECTION; HYDROGEN-SULFIDE; GAS-CHROMATOGRAPHY; CYCLIC VOLTAMMETRY; STATIONARY PHASES; CARBON ELECTRODE; ASCORBIC-ACID; SENSOR;
D O I
10.1002/elan.201200431
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here the preparation and application of a highly stable polymeric ionic liquid-modified electrode to immobilize ferricyanide for sulfide analysis. Good long-term stability of the modified electrode verifies its potential in sensor applications. The electrocatalytic sulfide oxidation signal at approximate to 0.0V vs. Ag/AgCl in pH7 PBS at the modified electrode was used for sulfide detection by hydrodynamic chronoamperometry and a detection limit of 12.9nM (S/N=3) was obtained. Practical utility of the system is applied to the determination of sulfide content in hot spring water and ground water.
引用
收藏
页码:845 / 849
页数:5
相关论文
共 28 条
[1]   Immobilized ionic liquids as high-selectivity/high-temperature/high-stability gas chromatography stationary phases [J].
Anderson, JL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6453-6462
[2]   Examination of ionic liquids and their interaction with molecules, when used as stationary phases in gas chromatography [J].
Armstrong, DW ;
He, LF ;
Liu, YS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3873-3876
[3]   Sulfide measurements by flow injection analysis and ion chromatography with electrochemical detection [J].
Casella, IG ;
Guascito, MR ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) :27-34
[4]   Amperometric detection of sulfur-containing compounds in alkaline media [J].
Casella, IG ;
Contursi, M ;
Desimoni, E .
ANALYST, 2002, 127 (05) :647-652
[5]   Screen-printed ionic liquid/preanodized carbon electrode: Effective detection of dopamine in the presence of high concentration of ascorbic acid [J].
Chang, Jen-Lin ;
Wei, Guor-Tzo ;
Zen, Jyh-Myng .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (02) :174-177
[6]   Pulsed amperometric detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate with microfabricated disposable silver working electrodes in ion chromatography [J].
Cheng, J ;
Jandik, P ;
Avdalovic, N .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :267-274
[7]   CHARGE TRANSPORT BY ELECTRON EXCHANGE CROSS REACTION IN CYCLIC VOLTAMMETRY OF IRCL63(-)-FE(CN)63- MIXTURES TRAPPED IN POLYCATIONIC FILMS ON ELECTRODES [J].
FACCI, J ;
MURRAY, RW .
JOURNAL OF PHYSICAL CHEMISTRY, 1981, 85 (20) :2870-2873
[8]   Amperometric determination of sulfide at a pre-oxidised nickel electrode in acidic media [J].
Giovanelli, D ;
Lawrence, NS ;
Jiang, L ;
Jones, TGJ ;
Compton, RG .
ANALYST, 2003, 128 (02) :173-177
[9]   An amperometric microsensor for the determination of H2S in aquatic environments [J].
Jeroschewski, P ;
Steuckart, C ;
Kuhl, M .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4351-4357
[10]   The catalytic activity of vanadium pentoxide film modified electrode on the electrochemical oxidation of hydrogen sulfide in alkaline solutions [J].
Khudaish, EA ;
Al-Hinai, AT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 587 (01) :108-114