Meta-Analysis of Comparison Between Self-Expandable and Balloon-Expandable Valves for Patients Having Transcatheter Aortic Valve Implantation

被引:14
|
作者
Moretti, Claudio [1 ]
D'Ascenzo, Fabrizio [1 ]
Mennuni, Marco [4 ]
Taha, Salma [1 ,5 ]
Brambilla, Nedy [6 ]
Nijhoff, Freek [7 ]
Fraccaro, Chiara [8 ]
Barbanti, Marco [9 ]
Tamburino, Corrado [9 ]
Tarantini, Giuseppe [8 ]
Rossi, Marco L. [4 ]
Presbitero, Patrizia [4 ]
Napodanno, Massimo [8 ]
Stella, Pieter [7 ]
Bedogni, Francesco [6 ]
Omede, Pierluigi [1 ]
Conrotto, Federico [2 ]
Montefusco, Antonio [1 ]
Giordana, Francesca [1 ]
Zoccai, Giuseppe Biondi [10 ]
Agostoni, Piefrancesco [7 ]
D'Amico, Maurizio [2 ]
Rinaldi, Mauro [3 ]
Marra, Sebastiano [2 ]
Gaita, Fiorenzo [1 ]
机构
[1] Univ Turin, Citta Salute & Sci Hosp, Div Cardiol 1, Turin, Italy
[2] Univ Turin, Citta Salute & Sci Hosp, Div Cardiol 2, Turin, Italy
[3] Univ Turin, Citta Salute & Sci Hosp, Div Cardiac Surg, Turin, Italy
[4] Ist Humanitas, Div Cardiol, Milan, Italy
[5] Assuit Univ Hosp, Dept Cardiol, Assiut, Egypt
[6] Ist Clin S Ambrogio, Dept Intervent Cardiol, Milan, Italy
[7] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[8] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Div Cardiol, Padua, Italy
[9] Univ Catania, Ferrarotto Hosp, Dept Cardiol, Catania, Italy
[10] Univ Roma La Sapienza, Dept Med Surg Sci & Biotechnol, I-00185 Rome, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2015年 / 115卷 / 12期
关键词
HIGH-RISK PATIENTS; EDWARDS-SAPIEN; MEDTRONIC-COREVALVE; CLINICAL-OUTCOMES; MIDTERM OUTCOMES; TERM OUTCOMES; TAVI; REGURGITATION; REPLACEMENT; STENOSIS;
D O I
10.1016/j.amjcard.2015.03.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two different devices, 1 self-expanding and 1 balloon-expandable, have been developed for patients who underwent transcatheter aortic valve implantation with contrasting data about efficacy and safety. Pubmed, Medline, and Google Scholar were systematically searched for studies of these different devices, with data derived from randomized controlled trial or registries with multivariate analysis. All-cause death at 30 days and at follow-up were the primary end points, whereas postprocedural moderate or severe aortic regurgitation (AR), stroke, major vascular complications, bleedings, and pacemaker implantation the secondary ones. Six studies with 957 self-expanding and 947 balloon-expandable valves were included: 1 randomized controlled trial and 5 observational studies. At 30 days follow-up, rates of death did not differ between self-expanding and balloon-expandable valves (odds ratio [OR] 0.74, 95% confidence interval [CI] 0.47 to 1.17), whereas balloon expandable reduced rates of moderate or severe AR (OR 0.51, 95% CI 0.27 to 0.99) and of pacemaker implantation (OR 0.28, 95% CI 0.17 to 0.47). After a follow-up of 360 days (300 to 390), rates of all-cause death did not differ between the 2 groups. In conclusion, risks of moderate or severe AR and pacemaker implantation were lower with the balloon-expandable devices without an impact on 30 days and midterm mortality. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1720 / 1725
页数:6
相关论文
共 50 条
  • [41] Clinical Outcomes of the Self-Expandable Evolut R Valve Versus the Balloon-Expandable SAPIEN 3 Valve in Transcatheter Aortic Valve Implantation: A Meta-Analysis and Systematic Review
    Al-Abcha, Abdullah
    Saleh, Yehia
    Charles, Lawrenshey
    Prasad, Rohan
    Baloch, Zulfiqar Qutrio
    Hasan, Mohanad A.
    Abela, George S.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 25 : 57 - 62
  • [42] Observed New Onset of Heart Block in the Self-Expandable and Balloon-Expandable Transcatheter Aortic Valve Implantation.
    Liang, Michael
    Devlin, Gerard
    Pasupati, Sanjeevan
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (8A): : 17A - 17A
  • [43] Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement
    Kisacik, Halil
    Tok, Derya
    Balci, Kevser Gulcihan
    Demirkan, Burcu
    Karakurt, Mustafa
    Acar, Burak
    Karabulut, Ozlem
    Erbay, Ilke
    Balci, Mustafa Mucahit
    ANGIOLOGY, 2021, 72 (03) : 290 - 294
  • [44] Trascatheter Aortic Valve Implantation Outcomes With Self-Expandable and Balloon-Expandable Devices in Patients with Mixed Aortic Valve Stenosis
    Giustino, Gennaro
    Montorfano, Matteo
    Agricola, Eustachio
    Chieffo, Alaide
    Panoulas, Vasileios F.
    Figini, Filippo
    Spagnolo, Pietro
    Latib, Azeem
    Alfieri, Ottavio
    Colombo, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B207 - B207
  • [45] Thrombocytopenia after transcatheter aortic valve implantation. A comparison between balloon-expandable and self-expanding valves
    Hernandez-Enriquez, Marco
    Regueiro, Ander
    Romaguera, Rafael
    Andrea, Rut
    Antoni Gomez-Hospital, Joan
    Pujol-Lopez, Margarida
    Luis Ferreiro-Gutierrez, Jose
    Brugaletta, Salvatore
    Roura, Gerard
    Freixa, Xavier
    Gomez-Lara, Josep
    Martin-Yuste, Victoria
    Gracida, Montserrat
    Cequier, Angel
    Sabate, Manel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : 1344 - 1351
  • [46] Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Montone, Rocco A.
    Testa, Luca
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 235 - 236
  • [47] Transcatheter Self-Expandable Aortic Valve Implantation in the Expandable Surgical Aortic Valve
    Hirota, Masataka
    Domoto, Satoru
    Inagaki, Yusuke
    Yoshikawa, Masafumi
    Yamaguchi, Junichi
    Niinami, Hiroshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (11) : 1397 - 1399
  • [48] Balloon-expandable or self-expandable transcatheter heart valves. Which are best?
    Webb, John
    Wood, David
    Sathananthan, Janarthanan
    Landes, Uri
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1900 - 1902
  • [49] Aortic Angulation Does Not Impact Outcomes in Self-Expandable or Balloon-Expandable Transcatheter Aortic Valve Replacement
    Elmously, Adham
    Gray, Katherine D.
    Truong, Quynh A.
    Burshtein, Aaron
    Wong, S. Chiu
    de Biasi, Andreas R.
    Worku, Berhane
    Salemi, Arash
    CARDIOLOGY, 2018, 140 (02) : 96 - 102
  • [50] Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves
    Hatoum, Hoda
    Hahn, Rebecca T.
    Lilly, Scott
    Dasi, Lakshmi Prasad
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 860 - 867