Meta-Analysis of Comparison Between Self-Expandable and Balloon-Expandable Valves for Patients Having Transcatheter Aortic Valve Implantation

被引:14
|
作者
Moretti, Claudio [1 ]
D'Ascenzo, Fabrizio [1 ]
Mennuni, Marco [4 ]
Taha, Salma [1 ,5 ]
Brambilla, Nedy [6 ]
Nijhoff, Freek [7 ]
Fraccaro, Chiara [8 ]
Barbanti, Marco [9 ]
Tamburino, Corrado [9 ]
Tarantini, Giuseppe [8 ]
Rossi, Marco L. [4 ]
Presbitero, Patrizia [4 ]
Napodanno, Massimo [8 ]
Stella, Pieter [7 ]
Bedogni, Francesco [6 ]
Omede, Pierluigi [1 ]
Conrotto, Federico [2 ]
Montefusco, Antonio [1 ]
Giordana, Francesca [1 ]
Zoccai, Giuseppe Biondi [10 ]
Agostoni, Piefrancesco [7 ]
D'Amico, Maurizio [2 ]
Rinaldi, Mauro [3 ]
Marra, Sebastiano [2 ]
Gaita, Fiorenzo [1 ]
机构
[1] Univ Turin, Citta Salute & Sci Hosp, Div Cardiol 1, Turin, Italy
[2] Univ Turin, Citta Salute & Sci Hosp, Div Cardiol 2, Turin, Italy
[3] Univ Turin, Citta Salute & Sci Hosp, Div Cardiac Surg, Turin, Italy
[4] Ist Humanitas, Div Cardiol, Milan, Italy
[5] Assuit Univ Hosp, Dept Cardiol, Assiut, Egypt
[6] Ist Clin S Ambrogio, Dept Intervent Cardiol, Milan, Italy
[7] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[8] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Div Cardiol, Padua, Italy
[9] Univ Catania, Ferrarotto Hosp, Dept Cardiol, Catania, Italy
[10] Univ Roma La Sapienza, Dept Med Surg Sci & Biotechnol, I-00185 Rome, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2015年 / 115卷 / 12期
关键词
HIGH-RISK PATIENTS; EDWARDS-SAPIEN; MEDTRONIC-COREVALVE; CLINICAL-OUTCOMES; MIDTERM OUTCOMES; TERM OUTCOMES; TAVI; REGURGITATION; REPLACEMENT; STENOSIS;
D O I
10.1016/j.amjcard.2015.03.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two different devices, 1 self-expanding and 1 balloon-expandable, have been developed for patients who underwent transcatheter aortic valve implantation with contrasting data about efficacy and safety. Pubmed, Medline, and Google Scholar were systematically searched for studies of these different devices, with data derived from randomized controlled trial or registries with multivariate analysis. All-cause death at 30 days and at follow-up were the primary end points, whereas postprocedural moderate or severe aortic regurgitation (AR), stroke, major vascular complications, bleedings, and pacemaker implantation the secondary ones. Six studies with 957 self-expanding and 947 balloon-expandable valves were included: 1 randomized controlled trial and 5 observational studies. At 30 days follow-up, rates of death did not differ between self-expanding and balloon-expandable valves (odds ratio [OR] 0.74, 95% confidence interval [CI] 0.47 to 1.17), whereas balloon expandable reduced rates of moderate or severe AR (OR 0.51, 95% CI 0.27 to 0.99) and of pacemaker implantation (OR 0.28, 95% CI 0.17 to 0.47). After a follow-up of 360 days (300 to 390), rates of all-cause death did not differ between the 2 groups. In conclusion, risks of moderate or severe AR and pacemaker implantation were lower with the balloon-expandable devices without an impact on 30 days and midterm mortality. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1720 / 1725
页数:6
相关论文
共 50 条
  • [31] Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A NationWide Study
    Sa, Young Kyoung
    Choi, Ik Jun
    Chang, Kiyuk
    Hwang, Byung-Hee
    Chung, Woo-Baek
    Lee, Kwan Yong
    Choo, Eun-Ho
    Kim, Chan Joon
    Park, Mahn Won
    Choi, Yoon Seok
    Park, Chul Soo
    Yoo, Ki Dong
    Jeon, Doo Soo
    Oak, Min -Ho
    Lee, Jungkuk
    Kang, Dongwoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 119 - 125
  • [32] Self-expandable valve implantation within a failed balloon-expandable valve
    Kornowski, Ran
    Codner, Pablo
    Vaknin-Assa, Hana
    Assali, Abid
    EUROINTERVENTION, 2014, 10 (08) : 1001 - 1001
  • [33] Comparison of latest generation transfemoral self-expandable and balloon-expandable transcatheter heart valves
    Schaefer, Andreas
    Linder, Matthias
    Seiffert, Moritz
    Schoen, Gerhard
    Deuschl, Florian
    Schofer, Niklas
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (06) : 905 - 911
  • [34] Myocardial Injury Post Transcatheter Aortic Valve Implantation Comparing Mechanically Expanded Versus Self-Expandable Versus Balloon-Expandable Valves
    Rahhab, Zouhair
    Labarre, Quentin
    Nijenhuis, Vincent J.
    El Faquir, Nahid
    de Biase, Chiara
    Philippart, Raphael
    Heijmen, Robin
    Kardys, Isabella
    Dumonteil, Nicolas
    de Jaegere, Peter
    van der Heijden, Jan
    Tchetche, Didier
    Van Mieghem, Nicolas M.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (05): : 431 - 437
  • [35] Valve Performance Between Latest-Generation Balloon-Expandable and Self-Expandable Transcatheter Heart Valves in a Small Aortic Annulus
    Hioki, Hirofumi
    Yamamoto, Masanori
    Shirai, Shinichi
    Ohno, Yohei
    Yashima, Fumiaki
    Naganuma, Toru
    Yamawaki, Masahiro
    Watanabe, Yusuke
    Yamanaka, Futoshi
    Mizutani, Kazuki
    Ryuzaki, Toshinobu
    Noguchi, Masahiko
    Izumo, Masaki
    Takagi, Kensuke
    Asami, Masahiko
    Ueno, Hiroshi
    Nishina, Hidetaka
    Otsuka, Toshiaki
    Suzuyama, Hiroto
    Yamasaki, Kazumasa
    Nishioka, Kenji
    Hachinohe, Daisuke
    Fuku, Yasushi
    Hayashida, Kentaro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2612 - 2622
  • [36] Short-term safety and efficacy of transcarotid transcatheter aortic valve implantation with balloon-expandable vs. self-expandable valves
    Hudziak, Damian
    Wanha, Wojciech
    Gocot, Radoslaw
    Parma, Radoslaw
    Ochala, Andrzej
    Smolka, Grzegorz
    Ciosek, Joanna
    Darocha, Tomasz
    Deja, Marek A.
    Wojakowski, Wojciech
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 75 - 81
  • [37] Balloon-Expandable versus Self-Expandable Valves in Transcatheter Aortic Valve Implantation: Complications and Outcomes from a Large International Patient Cohort
    van Nieuwkerk, Astrid C.
    Santos, Raquel B.
    Andraka, Leire
    Tchetche, Didier
    de Brito, Fabio S.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Ten, Francisco
    Dumonteil, Nicolas
    Baan, Jan
    Piek, Jan J.
    Abizaid, Alexandre
    Sartori, Samantha
    D'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Manuel Nogales-Asensio, Juan
    Ghattas, Angie
    Dangas, George
    Mehran, Roxana
    Delewi, Ronak
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (17)
  • [38] The Incidence of Transcatheter Aortic Valve Implantation-Related Heart Block in Self-Expandable Medtronic CoreValve and Balloon-Expandable Edwards Valves
    Liang, Michael
    Devlin, Gerard
    Pasupati, Sanjeevan
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (04): : 173 - 176
  • [39] Balloon-expandable versus Self-expandable transcatheter aortic valve replacement for failed surgical prostheses: A systematic review and meta-analysis
    Awad, Ahmed K.
    Khalefa, Basma
    Yassin, Mazen Negmeldin Aly
    Arnaout, Moumen
    Mostafa, Naydeen
    Naeem, Mariana S.
    Eljadid, Ghaith
    Gardezi, Syed Karam
    CIRCULATION, 2024, 150
  • [40] Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial
    Thiele, Holger
    Kurz, Thomas
    Feistritzer, Hans-Josef
    Stachel, Georg
    Hartung, Philipp
    Eitel, Ingo
    Marquetand, Christoph
    Nef, Holger
    Doerr, Oliver
    Lauten, Alexander
    Landmesser, Ulf
    Abdel-Wahab, Mohamed
    Sandri, Marcus
    Holzhey, David
    Borger, Michael
    Ince, Hueseyin
    Oener, Alper
    Meyer-Saraei, Roza
    Wienbergen, Harm
    Fach, Andreas
    Frey, Norbert
    Koenig, Inke R.
    Vonthein, Reinhard
    Rueckert, Yvonne
    Funkat, Anne-Kathrin
    de Waha-Thiele, Suzanne
    Desch, Steffen
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1890 - +