Design of a small animal MR compatible PET scanner

被引:59
作者
Slates, R [1 ]
Cherry, S
Boutefnouchet, A
Shao, YP
Dahlbom, M
Farahani, K
机构
[1] Univ Calif Los Angeles, Crump Inst Biol Imaging, Dept Mol & Med Pharmacol, Sch Med, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Dept Radiol Sci, Sch Med, Los Angeles, CA USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.775580
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a combination of Monte-Carlo simulations and experimental measurements we have designed a small animal MR compatible PET (McPET) scanner for simultaneous PET and MR imaging of mice and rats in vivo. The scanner consists of one ring of 480 LSO crystals arranged in 3 layers with 160 crystals per layer. The crystal dimensions are 2 x 3 x 7.5 mm(3). This was based on a target resolution of 2.5 mm and simulations showing that a depth of 7.5 mm avoided significant depth of interaction effects across the desired field of view. The system diameter of 11.2 cm is large enough to accommodate the animal positioned inside a stereotactic frame. Each crystal will be coupled through 2 mm diameter optical fibers to multi-channel PMT's which reside outside the main magnetic field. Through 50 cm of optical fiber, a photopeak is clearly seen and the measured energy resolution is 25%. Prototype optical fiber connectors have been tested to increase the flexibility of the system and result in a light loss of only 6%. The proposed system will have adequate resolution and sensitivity for a number of applications in small animals and will be the first practical device for simultaneous in vivo imaging with PET and MR.
引用
收藏
页码:565 / 570
页数:6
相关论文
共 16 条
[1]  
CHATZIIOANNOU A, IN PRESS J NUCL MED
[2]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[3]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[4]   OPTIMIZATION OF PET INSTRUMENTATION FOR BRAIN ACTIVATION STUDIES [J].
DAHLBOM, M ;
CHERRY, SR ;
ERIKSSON, L ;
HOFFMAN, EJ ;
WIENHARD, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1048-1054
[5]  
FARAHANI K, IN PRESS J MAGNETIC
[6]  
Garlick PB, 1997, NMR BIOMED, V10, P138, DOI 10.1002/(SICI)1099-1492(199705)10:3<138::AID-NBM474>3.0.CO
[7]  
2-H
[8]  
HUBER JS, UNPUB NUCL INSTRUMEN
[9]  
*KUR CO, SCINT MAT CAT
[10]   Parallax correction in PET using depth of interaction information [J].
MacDonald, LR ;
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2232-2237