摘要
Patient-specific simulations of bone remodelling could enable predicting how bone micro-structural integrity would be affected by bone diseases, drugs or other factors, and, ultimately could help clinicians to improve their prognoses. To simulate load-adaptive remodelling, however, knowledge about the physiological external loading acting on the bone is required. Assuming that load adaptation leads to homogeneous tissue loading, we previously developed a method to estimate the physiological loading history from bone micro-structural morphology. We were able to reconstruct the loading history of a simple load case that was applied in an animal experiment. However, we found considerable inhomogeneity in tissue loading suggesting that the bones were not fully adapted. Also, we noted differences in bone micro-architecture between animals despite common loading history, possibly due to differences caused by the stochastic nature of the bone remodelling process. In the present study, we aim at validating the load estimation algorithm in a well-controlled environment in which more complicated loading conditions are applied. Specifically, we want to test its accuracy for partially and fully developed bone structures and for differences in bone micro-architectures as they can occur due to stochastic events, even for bones with a common loading history. This was possible by using synthetic micro-architectures obtained from bone remodelling simulations as the basis for our load estimation algorithm. Loading histories based on fully adapted structures were predicted with a maximum error of 4.4% and predictions were not affected by differences in bone micro-architecture. These results show that our load estimation algorithm produces reasonable predictions and might be a suitable tool to define in vivo loading for patient-specific bone remodelling studies. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [21] Patient-specific in silico models can quantify primary implant stability in elderly human bone
    Steiner, Juri A.
    Hofmann, Urs A. T.
    Christen, Patrik
    Favre, Jean M.
    Ferguson, Stephen J.
    van Lenthe, G. Harry
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (03) : 954 - +
  • [22] Patient-specific microarchitecture of vertebral cancellous bone: A peripheral quantitative computed tomographic and histological study
    Banse, X
    Devogelaer, JP
    Grynpas, M
    BONE, 2002, 30 (06) : 829 - 835
  • [23] Patient-specific numerical simulation of the bone healing process including implant materials and gait conditions
    Martinez-Martinez, A.
    Nadal, E.
    Bonete, D.
    Allix, O.
    Rodenas, J. J.
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2024, 236
  • [24] Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors
    Lekadir, Karim
    Noble, Christopher
    Hazrati-Marangalou, Javad
    Hoogendoorn, Corn
    van Rietbergen, Bert
    Taylor, Zeike A.
    Frangi, Alejandro F.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (01) : 234 - 246
  • [25] Patient-specific simulations of transcatheter aortic valve stent implantation
    Capelli, C.
    Bosi, G. M.
    Cerri, E.
    Nordmeyer, J.
    Odenwald, T.
    Bonhoeffer, P.
    Migliavacca, F.
    Taylor, A. M.
    Schievano, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 183 - 192
  • [26] A framework for analytical estimation of patient-specific CT dose
    Youn, Hanbean
    Kim, Jin Woo
    Jeon, Hosang
    Nam, Jiho
    Yun, Seungman
    Cho, Min Kook
    Kim, Ho Kyung
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [27] A Parametric Study on a Dental Implant Geometry Influence on Bone Remodelling through a Numerical Algorithm
    Santonocito, Dario
    Nicita, Fabiana
    Risitano, Giacomo
    PROSTHESIS, 2021, 3 (02): : 157 - 172
  • [28] Tissue-level remodeling simulations of cancellous bone capture effects of in vivo loading in a rabbit model
    Morgan, Timothy G.
    Bostrom, Mathias P. G.
    van der Meulen, Marjolein C. H.
    JOURNAL OF BIOMECHANICS, 2015, 48 (05) : 875 - 882
  • [29] Is a patient-specific drill template via a cortical bone trajectory safe in cervical anterior transpedicular insertion?
    Peng Peng
    Yafei Xu
    Xintao Zhang
    Meisong Zhu
    Bingran Du
    Wenrui Li
    Wenhua Huang
    Jun Song
    Jianyi Li
    Journal of Orthopaedic Surgery and Research, 13
  • [30] Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty
    Yamamura, Kazumasa
    Inori, Fumiaki
    Konishi, Sadahiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (09) : 1583 - 1590