Systematic umbilical cord blood analysis at birth: Feasibility and reliability in a French labour ward

被引:2
作者
Ernst, D. [1 ]
Clerc, J. [1 ]
Decullier, E. [2 ,3 ,4 ]
Gavanier, G. [5 ]
Dupuis, O. [1 ]
机构
[1] Hosp Civils Lyon, Ctr Hosp Univ Lyon S, Serv Gynecol Obstet, F-69310 Pierre Benite, France
[2] Hosp Civils Lyon, Ctr Hosp Univ Lyon S, F-69003 Lyon, France
[3] Univ Lyon, RECIF, EA Sante Individu Soc 4129, F-69002 Lyon, France
[4] Univ Lyon 1, F-69008 Lyon, France
[5] Ecole Polytech, Dept Mecan, F-91128 Palaiseau, France
来源
GYNECOLOGIE OBSTETRIQUE & FERTILITE | 2012年 / 40卷 / 10期
关键词
Umbilical cord blood; Gas analysis; Feasibility; Reliability; Quality criteria; Cord pH; Validation; GAS-ANALYSIS; CEREBRAL-PALSY; DELIVERY; TIME; ARTERIAL; INFANTS; EVENTS; TERM; TOOL; PH;
D O I
10.1016/j.gyobfe.2012.05.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives. - At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Patients and methods. - Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. Results. - The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P < 0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P < 0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Discussion and conclusion. - Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. (c) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:566 / 571
页数:6
相关论文
共 29 条
  • [1] [Anonymous], 2006, Obstetrics and Gynecology, V108, P1319
  • [2] APGAR V, 1953, ANESTH ANALG CLEVE, V32, P260, DOI DOI 10.1213/00000539-195301000-00041
  • [3] Cord blood oxygen saturation in vigorous infants at birth: what is normal?
    Arikan, GM
    Scholz, HS
    Petru, E
    Haeusler, MCH
    Haas, J
    Weiss, PAM
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (08): : 987 - 994
  • [4] Armstrong L, 2007, ARCH DIS CHILD-FETAL, V92, P430
  • [5] Cerebral palsy and perinatal asphyxia (II - Medicolegal implications and prevention)
    Boog, G.
    [J]. GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2011, 39 (03): : 146 - 173
  • [6] Cerebral palsy and perinatal asphyxia (I-Diagnosis)
    Boog, G.
    [J]. GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2010, 38 (04): : 261 - 277
  • [7] Umbilical cord blood sampling - A tool for delivery quality control?
    Bulkmans, N
    Lyrenas, S
    Hallberg, G
    Niklasson, F
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1997, 76 (05) : 419 - 422
  • [8] Carbonne B, 2007, SPECTRA BIOL, V161, P64
  • [9] CNGOF, 2007, MOD SURV PEND TRAV R
  • [10] The Apgar score has survived the test of time
    Finster, M
    Wood, M
    [J]. ANESTHESIOLOGY, 2005, 102 (04) : 855 - 857