On the verification of the incident energy fluence in tomotherapy IMRT

被引:24
作者
Kapatoes, JM
Olivera, GH
Ruchala, KJ
Mackie, TR
机构
[1] TomoTherapy Inc, Middleton, WI 53562 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
关键词
D O I
10.1088/0031-9155/46/11/313
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For any radiotherapy verification technique, it is desirable that issues with the accelerator, multileaf collimator and patient position be detected. In previous works, an effective method for this level of verification was presented. This paper identifies second-order issues affecting the part of the process in which the incident energy fluence is verified. These problems will affect any rotational intensity-modulated radiotherapy delivery that divides each rotation or arc into projections; however the solutions offered in this paper are specific to the method previously developed. The issues affecting the energy fluence verification method include leaf bouncing, delivery implementation and leaf latency. All three matters were found to introduce small errors in the verified energy fluence values for a small fraction of leaf states. The overall effect on the deposited dose over the course of a rotational delivery involving thousands of beam pulses per rotation is negligible. Regardless, effective correction strategies are presented; these are utilized in order to characterize both the delivered energy fluence and deposited dose as accurately as possible.
引用
收藏
页码:2953 / 2965
页数:13
相关论文
共 36 条
  • [21] Modeling dose distributions from portal dose images using the convolution/superposition method
    McNutt, TR
    Mackie, TR
    Reckwerdt, P
    Paliwal, BR
    [J]. MEDICAL PHYSICS, 1996, 23 (08) : 1381 - 1392
  • [22] Rapid portal imaging with a high-efficiency, large field-of-view detector
    Mosleh-Shirazi, MA
    Evans, PM
    Swindell, W
    Symonds-Tayler, JRN
    Webb, S
    Partridge, M
    [J]. MEDICAL PHYSICS, 1998, 25 (12) : 2333 - 2346
  • [23] Olivera GH, 1999, MODERN TECHNOLOGY OF RADIATION ONCOLOGY, P521
  • [24] OLIVERA GH, 2001, MED PHYS SE, P261
  • [25] Leaf position verification during dynamic beam delivery: A comparison of three applications using electronic portal imaging
    Partridge, M
    Evans, PM
    van Herk, M
    Ploeger, LS
    Budgell, GJ
    James, HV
    [J]. MEDICAL PHYSICS, 2000, 27 (07) : 1601 - 1609
  • [26] IMRT verification with a camera-based electronic portal imaging system
    Partridge, M
    Symonds-Tayler, JRN
    Evans, PM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) : N183 - N196
  • [27] Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    Pasma, KL
    Dirkx, MLP
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2373 - 2378
  • [28] RUCHALA K, 1999, THESIS U WISCONSIN M
  • [29] Megavoltage CT on a tomotherapy system
    Ruchala, KJ
    Olivera, GH
    Schloesser, EA
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10) : 2597 - 2621
  • [30] Megavoltage CT image reconstruction during tomotherapy treatments
    Ruchala, KJ
    Olivera, GH
    Kapatoes, JM
    Schloesser, EA
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) : 3545 - 3562