Capacitively coupled contactless conductivity detection for microfluidic capillary isoelectric focusing

被引:12
|
作者
Chau, Minh Khang [1 ]
Arega, Nebiyu Getachew [1 ]
Nguyen Anh Nhung Tran [2 ]
Song, Jin [1 ]
Lee, Sangmin [2 ]
Kim, Jintae [3 ]
Chung, Minsub [2 ]
Kim, Dohyun [1 ,4 ]
机构
[1] Myongji Univ, Dept Mech Engn, Yongin 17508, Gyeonggi Do, South Korea
[2] Hongik Univ, Dept Chem Engn, Seoul 04066, South Korea
[3] Konkuk Univ, Dept Elect Engn, Seoul 05029, South Korea
[4] Myongji Univ, Nat Sci Res Inst, Yongin 17508, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Microfluidic isoelectric focusing; Protein analysis; Protein separation; Capacitively coupled contactless conductivity detection; Label-free detection; Numerical simulation; CARRIER AMPHOLYTES; PROTEIN SEPARATION; IMAGING-SYSTEM; ELECTROPHORESIS; MICROCHIP; CHIP; INTEGRATION; MOBILIZATION; PERFORMANCE; MICROSCOPY;
D O I
10.1016/j.aca.2020.05.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report capacitively coupled contactless conductivity detection (C4D) of proteins separated by microfluidic capillary isoelectric focusing (mu CIEF). To elucidate the evolution of negative conductivity peaks during focusing and seek IEF conditions for sensitive conductivity detection, numerical simulation was performed using a model protein GFP (green fluorescence protein) and hypothetical carrier ampholytes (CAs). C4D was successfully applied to the mu CIEF by optimizing assay conditions using a simple and effective pressure-mobilization approach. The conductivity and fluorescence signals of a focused GFP band were co-detected, confirming that the obtained negative C4D peak could be attributed to the actual protein, not the non-uniform background conductivity profile of the focused CAs. GFP concentrations of 10 nM-30 mu M was quantified with a detection limit of 10 nM. Finally, the resolving power was analyzed by separating a mixture of R-phycoerythrin (pI 5.01), GFP-F64L (pI 5.48), and RK-GFP (pI 6.02). The conductivities of the three separated fluorescence proteins were measured with average separation resolution of 2.06. We expect the newly developed label-free mu CIEF-C4D technique to be widely adopted as a portable, electronics-only protein-analysis tool. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 50 条
  • [41] Advanced online mass spectrometry detection of proteins separated by capillary isoelectric focusing after sequential injection
    Pager, Csilla
    Biherczova, Nikoleta
    Ligetvari, Roland
    Berkics, Balazs Viktor
    Pongracz, Tamas
    Sandor, Viktor
    Bufa, Anita
    Poor, Viktoria
    Stanova, Andrea Vojs
    Kilar, Ferenc
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (24) : 4825 - 4834
  • [42] Capillary isoelectric focusing coupled offline to matrix assisted laser desorption/ionization mass spectrometry
    Weiss, Noah G.
    Zwick, Nicole L.
    Hayes, Mark A.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (01) : 179 - 182
  • [43] Characterization of human papillomavirus by capillary isoelectric focusing with whole-column imaging detection
    Zhou, Chao-Ming
    ELECTROPHORESIS, 2013, 34 (20-21) : 3046 - 3053
  • [44] Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection
    Pormsila, Worapan
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ELECTROPHORESIS, 2010, 31 (13) : 2186 - 2191
  • [45] Capillary isoelectric isoelectric focusing with whole column imaging detection (iCIEF): A new approach to the characterization and quantification of salivary α-amylase
    Zarabadi, Atefeh S.
    Huang, Tiemin
    Mielke, John G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1053 : 65 - 71
  • [46] A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis
    Chen, Zuanguang
    Li, Quanwen
    Li, Oulian
    Zhou, Xie
    Lan, You
    Wei, Yuanfang
    Mo, Jinyuan
    TALANTA, 2007, 71 (05) : 1944 - 1950
  • [47] Two-dimensional capillary electrophoresis: Capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection
    Dickerson, Jane A.
    Ramsay, Lauren M.
    Dada, Oluwatosin O.
    Cermak, Nathan
    Dovichi, Norman J.
    ELECTROPHORESIS, 2010, 31 (15) : 2650 - 2654
  • [48] Capillary electrophoresis and isoelectric focusing in peptide and protein analysis
    Righetti, Pier Giorgio
    Sebastiano, Roberto
    Citterio, Attilio
    PROTEOMICS, 2013, 13 (02) : 325 - 340
  • [49] Preparation of capillary isoelectric focusing with monolithic immobilized pH gradient and its application in determination of isoelectric point of proteins
    Liu Rangdong
    Xu Xinyao
    Wang Weiwei
    Wang Yan
    Yan Chao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (10) : 1090 - 1097
  • [50] Application of capillary isoelectric focusing and peptide mass fingerprinting in carbohydrate-deficient transferrin detection
    Luo, Lian-Zhong
    Jin, Hong-Wei
    Huang, He-Qing
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (10) : 1391 - 1398