Capacitively coupled contactless conductivity detection for microfluidic capillary isoelectric focusing

被引:12
|
作者
Chau, Minh Khang [1 ]
Arega, Nebiyu Getachew [1 ]
Nguyen Anh Nhung Tran [2 ]
Song, Jin [1 ]
Lee, Sangmin [2 ]
Kim, Jintae [3 ]
Chung, Minsub [2 ]
Kim, Dohyun [1 ,4 ]
机构
[1] Myongji Univ, Dept Mech Engn, Yongin 17508, Gyeonggi Do, South Korea
[2] Hongik Univ, Dept Chem Engn, Seoul 04066, South Korea
[3] Konkuk Univ, Dept Elect Engn, Seoul 05029, South Korea
[4] Myongji Univ, Nat Sci Res Inst, Yongin 17508, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Microfluidic isoelectric focusing; Protein analysis; Protein separation; Capacitively coupled contactless conductivity detection; Label-free detection; Numerical simulation; CARRIER AMPHOLYTES; PROTEIN SEPARATION; IMAGING-SYSTEM; ELECTROPHORESIS; MICROCHIP; CHIP; INTEGRATION; MOBILIZATION; PERFORMANCE; MICROSCOPY;
D O I
10.1016/j.aca.2020.05.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report capacitively coupled contactless conductivity detection (C4D) of proteins separated by microfluidic capillary isoelectric focusing (mu CIEF). To elucidate the evolution of negative conductivity peaks during focusing and seek IEF conditions for sensitive conductivity detection, numerical simulation was performed using a model protein GFP (green fluorescence protein) and hypothetical carrier ampholytes (CAs). C4D was successfully applied to the mu CIEF by optimizing assay conditions using a simple and effective pressure-mobilization approach. The conductivity and fluorescence signals of a focused GFP band were co-detected, confirming that the obtained negative C4D peak could be attributed to the actual protein, not the non-uniform background conductivity profile of the focused CAs. GFP concentrations of 10 nM-30 mu M was quantified with a detection limit of 10 nM. Finally, the resolving power was analyzed by separating a mixture of R-phycoerythrin (pI 5.01), GFP-F64L (pI 5.48), and RK-GFP (pI 6.02). The conductivities of the three separated fluorescence proteins were measured with average separation resolution of 2.06. We expect the newly developed label-free mu CIEF-C4D technique to be widely adopted as a portable, electronics-only protein-analysis tool. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 50 条
  • [11] Double Input Capacitively Coupled Contactless Conductivity Detector with Phase Shift
    Zheng, Hao
    Li, Meng
    Dai, Jianyuan
    Wang, Zhen
    Li, Xiuting
    Yuan, Hongyan
    Xiao, Dan
    ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10065 - 10070
  • [12] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [13] Capillary Isoelectric Focusing of Individual Mitochondria
    Wolken, Gregory G.
    Kostal, Vratislav
    Arriaga, Edgar A.
    ANALYTICAL CHEMISTRY, 2011, 83 (02) : 612 - 618
  • [14] Electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection: Multi-extraction capabilities to analyses trace metals from saline samples
    Silva, Macarena
    Mendiguchia, Carolina
    Moreno, Carlos
    Kuban, Pavel
    ELECTROPHORESIS, 2018, 39 (16) : 2152 - 2159
  • [15] Dual fluorescence/contactless conductivity detection for microfluidic chip
    Liu, Cui
    Mo, Yun-yan
    Chen, Zuan-guang
    Li, Xiang
    Li, Ou-lian
    Zhou, Xie
    ANALYTICA CHIMICA ACTA, 2008, 621 (02) : 171 - 177
  • [16] FREE FLOW ISOELECTRIC FOCUSING IN A MICROFLUIDIC DEVICE
    Yoo, Kisoo
    Dutta, Prashanta
    Liu, Jin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 7, 2015,
  • [17] A Capacitively Coupled Contactless Conductivity Detector for High Performance Liquid Chromatography Detection and Its Application in Pharmaceutical Analysis
    Zhang Kai-Peng
    Yang Xiu-Juan
    Zhang Lin
    Chen Zuan-Guang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (03) : 348 - 353
  • [18] Optimization of physical parameters of 'injected' metal electrodes for capacitively coupled contactless conductivity detection on poly(dimethylsiloxane) microchips
    Thredgold, Leigh D.
    Khodakov, Dmitriy A.
    Ellis, Amanda V.
    Lenehan, Claire E.
    MICRO/NANO MATERIALS, DEVICES, AND SYSTEMS, 2013, 8923
  • [19] Preparation of a capillary isoelectric focusing column with monolithic immobilized pH gradient and its application on protein separation based on an online capillary isoelectric focusing platform
    Liu, Rangdong
    Pan, Hong
    Zheng, Yiting
    Hu, Jing
    Cheddah, Soumia
    Wang, Weiwei
    Wang, Yan
    Yan, Chao
    ELECTROPHORESIS, 2019, 40 (12-13) : 1722 - 1730
  • [20] Capillary isoelectric focusing of proteins
    Pritchett, TJ
    ELECTROPHORESIS, 1996, 17 (07) : 1195 - 1201