Capacitively coupled contactless conductivity detection for microfluidic capillary isoelectric focusing

被引:12
|
作者
Chau, Minh Khang [1 ]
Arega, Nebiyu Getachew [1 ]
Nguyen Anh Nhung Tran [2 ]
Song, Jin [1 ]
Lee, Sangmin [2 ]
Kim, Jintae [3 ]
Chung, Minsub [2 ]
Kim, Dohyun [1 ,4 ]
机构
[1] Myongji Univ, Dept Mech Engn, Yongin 17508, Gyeonggi Do, South Korea
[2] Hongik Univ, Dept Chem Engn, Seoul 04066, South Korea
[3] Konkuk Univ, Dept Elect Engn, Seoul 05029, South Korea
[4] Myongji Univ, Nat Sci Res Inst, Yongin 17508, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Microfluidic isoelectric focusing; Protein analysis; Protein separation; Capacitively coupled contactless conductivity detection; Label-free detection; Numerical simulation; CARRIER AMPHOLYTES; PROTEIN SEPARATION; IMAGING-SYSTEM; ELECTROPHORESIS; MICROCHIP; CHIP; INTEGRATION; MOBILIZATION; PERFORMANCE; MICROSCOPY;
D O I
10.1016/j.aca.2020.05.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report capacitively coupled contactless conductivity detection (C4D) of proteins separated by microfluidic capillary isoelectric focusing (mu CIEF). To elucidate the evolution of negative conductivity peaks during focusing and seek IEF conditions for sensitive conductivity detection, numerical simulation was performed using a model protein GFP (green fluorescence protein) and hypothetical carrier ampholytes (CAs). C4D was successfully applied to the mu CIEF by optimizing assay conditions using a simple and effective pressure-mobilization approach. The conductivity and fluorescence signals of a focused GFP band were co-detected, confirming that the obtained negative C4D peak could be attributed to the actual protein, not the non-uniform background conductivity profile of the focused CAs. GFP concentrations of 10 nM-30 mu M was quantified with a detection limit of 10 nM. Finally, the resolving power was analyzed by separating a mixture of R-phycoerythrin (pI 5.01), GFP-F64L (pI 5.48), and RK-GFP (pI 6.02). The conductivities of the three separated fluorescence proteins were measured with average separation resolution of 2.06. We expect the newly developed label-free mu CIEF-C4D technique to be widely adopted as a portable, electronics-only protein-analysis tool. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 50 条
  • [1] An automated scanning contactless conductivity detection device for microfluidic isoelectric focusing
    Dai, Haozheng
    Tian, Youli
    Tao, Zhimin
    Chen, Ke-Er
    Liu, Weiwen
    Zhang, Qiang
    Cao, Chengxi
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 430
  • [2] Capacitively coupled contactless conductivity detection on microfluidic systems-ten years of development
    Tomazelli Coltro, Wendell Karlos
    Lima, Renato Sousa
    Segato, Thiago Pinotti
    Carrilho, Emanuel
    de Jesus, Dosil Pereira
    do Lago, Claudimir Lucio
    Fracassi da Silva, Jose Alberto
    ANALYTICAL METHODS, 2012, 4 (01) : 25 - 33
  • [3] Metalless electrodes for capacitively coupled contactless conductivity detection on electrophoresis microchips
    Duarte Junior, Gerson F.
    Fracassi da Silva, Jose Alberto
    Mendonca Francisco, Kelliton Jose
    do Lago, Claudimir Lucio
    Carrilho, Emanuel
    Coltro, Wendell K. T.
    ELECTROPHORESIS, 2015, 36 (16) : 1935 - 1940
  • [4] Restrictive dual capacitively coupled contactless conductivity detection for microchip electrophoresis
    Mahabadi, Kambiz Ansari
    Rodriguez, Isabel
    Hong, Liu
    Hauser, Peter C.
    de Rooij, Nico F.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1351 - +
  • [5] Low Cost Electrodes Cell in Capacitively Coupled Contactless Conductivity Detector for Microfluidic Chemical Analysis
    Cao, X.
    Wang, Y.
    Hogan, A.
    Vazquez, P.
    Messina, W.
    Moore, E.
    2018 IEEE 18TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2018,
  • [6] Development of low-cost planar electrodes and microfluidic channels for applications in capacitively coupled contactless conductivity detection (C4D)
    Takekawa, Victor Sadanory
    Marques, Leticia Aparecida
    Strubinger, Ethan
    Segato, Thiago Pinotti
    Bogusz, Stanislau, Jr.
    Brazaca, Lais Canniatti
    Carrilho, Emanuel
    ELECTROPHORESIS, 2021, 42 (16) : 1560 - 1569
  • [7] In-plane alloy electrodes for capacitively coupled contactless conductivity detection in poly(methylmethacrylate) electrophoretic chips
    Gaudry, Adam J.
    Breadmore, Michael C.
    Guijt, Rosanne M.
    ELECTROPHORESIS, 2013, 34 (20-21) : 2980 - 2987
  • [8] Electrophoretic separations with polyether ether ketone capillaries and capacitively coupled contactless conductivity detection
    Tanyanyiwa, J
    Leuthardt, S
    Hauser, PC
    JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) : 205 - 211
  • [9] Capacitively coupled contactless conductivity detection for analytical techniques - Developments from 2018 to 2020
    Hauser, Peter C.
    Kuban, Pavel
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1632
  • [10] Microfluidic chips for capillary electrophoresis with integrated electrodes for capacitively coupled conductivity detection based on printed circuit board technology
    Guijt, Rosanne M.
    Armstrong, James P.
    Candish, Esme
    Lefleur, Veronica
    Percey, William J.
    Shabala, Sergey
    Hauser, Peter C.
    Breadmore, Michael C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 159 (01): : 307 - 313