Comparison of implant position and joint awareness between fixed- and mobile-bearing unicompartmental knee arthroplasty: a minimum of five year follow-up study

被引:6
作者
Kim, Man Soo [1 ]
Koh, In Jun [2 ]
Kim, Chul Kyu [1 ]
Choi, Keun Young [1 ]
Baek, Jong Won [1 ]
In, Yong [1 ]
机构
[1] Catholic Univ Korea, Dept Orthopaed Surg, Seoul St Marys Hosp, Coll Med, 222 Banpo Daero, Seoul 06591, South Korea
[2] Catholic Univ Korea, Dept Orthopaed Surg, Eunpyeong St Marys Hosp, Coll Med, 1021Tongil Ro, Seoul 03312, South Korea
关键词
Fixed-bearing; Mobile-bearing; Unicompartmental knee arthroplasty; Joint awareness; Forgotten joint score; KINEMATICS; ALIGNMENT; UKA;
D O I
10.1007/s00264-020-04662-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare the implant position and patient-reported outcomes (PROs) regarding joint awareness using the Forgotten Joint Score (FJS) following between fixed-bearing (FB) and mobile-bearing (MB) unicompartmental knee arthroplasty (UKA) with a minimum of five years' follow-up. Methods One hundred fifteen consecutive UKAs (58 FB UKAs and 57 MB UKAs) performed were retrospectively evaluated. We compared the radiographic parameters including component positions and relationships as well as lower extremity alignment. Post-operative clinical outcomes were assessed using Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Tegner activity score, and FJS. Results The MB UKA group showed more convergent componentry relationship between femoral and tibial components (p < 0.001). The joint line of the MB UKA group was restored significantly better (p < 0.05). In addition, the positioning of femoral and tibial components of the MB UKA group showed less deviation from the weight-bearing line (WBL) (p < 0.05). Although there were no differences in KSS, WOMAC, and Tegner activity scores between the groups, the MB UKA group showed significantly better FJS than did the FB UKA group at five years post-operatively (p < 0.05). Conclusion The MB UKA group had a more convergent componentry relationship, less deviation from WBL, better joint-line restoration, and reduced joint awareness than did the FB UKA group at five years follow-up.
引用
收藏
页码:2329 / 2336
页数:8
相关论文
共 26 条
[1]   Patient Reported Kneeling Ability in Fixed and Mobile Bearing Knee Arthroplasty [J].
Artz, Neil J. ;
Hassaballa, Mo A. ;
Robinson, James R. ;
Newman, John H. ;
Porteous, Andrew J. ;
Murray, James R. D. .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2159-2163
[2]   Metal backed fixed-bearing unicondylar knee arthroplasties using minimal invasive surgery: a promising outcome analysis of 132 cases [J].
Baur, Joel ;
Zwicky, Lukas ;
Hirschmann, Michael Tobias ;
Ilchmann, Thomas ;
Clauss, Martin .
BMC MUSCULOSKELETAL DISORDERS, 2015, 16
[3]   The "Forgotten Joint" as the Ultimate Goal in Joint Arthroplasty Validation of a New Patient-Reported Outcome Measure [J].
Behrend, Henrik ;
Giesinger, Karlmeinrad ;
Giesinger, Johannes M. ;
Kuster, Markus S. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (03) :430-436
[4]  
CARR A, 1993, CLIN ORTHOP RELAT R, P205
[5]   Comparison of a mobile with a fixed tibial bearing unicompartimental knee prosthesis: a prospective randomized trial using a dedicated outcome score [J].
Confalonieri, N ;
Manzotti, A ;
Pullen, C .
KNEE, 2004, 11 (05) :357-362
[6]   Comparison of a mobile with a fixed-bearing unicompartmental knee implant [J].
Emerson, RH ;
Hansborough, T ;
Reitman, RA ;
Rosenfeldt, W ;
Higgins, LL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :62-70
[7]   Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study [J].
Gleeson, RE ;
Evans, R ;
Ackroyd, CE ;
Webb, J ;
Newman, JH .
KNEE, 2004, 11 (05) :379-384
[8]  
Goodfellow J W, 1987, J Arthroplasty, V2, P1, DOI 10.1016/S0883-5403(87)80025-6
[9]   The effect of leg alignment on the outcome of unicompartmental knee replacement [J].
Gulati, A. ;
Pandit, H. ;
Jenkins, C. ;
Chau, R. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (04) :469-474
[10]   Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique [J].
Herry, Yannick ;
Batailler, Cecile ;
Lording, Timothy ;
Servien, Elvire ;
Neyret, Philippe ;
Lustig, Sebastien .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (11) :2265-2271