Surface modification of a medical grade Co-Cr-Mo alloy by low-temperature plasma surface alloying with nitrogen and carbon

被引:47
|
作者
Liu, Ran [1 ]
Li, Xiaoying [1 ]
Hu, Xiao [1 ]
Dong, Hanshan [1 ]
机构
[1] Univ Birmingham, Sch Met & Mat, Birmingham B15 2TT, W Midlands, England
来源
SURFACE & COATINGS TECHNOLOGY | 2013年 / 232卷
基金
英国工程与自然科学研究理事会;
关键词
Co-Cr alloy; Low-temperature plasma surface alloying; S-phase layer; Characterisation; MICROSTRUCTURAL CHARACTERIZATION;
D O I
10.1016/j.surfcoat.2013.06.122
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Cobalt-chromium (Co-Cr) alloys are one of the best materials for biomedical applications owing to their fairly good wear resistance, high mechanical properties, adequate corrosion resistance and acceptable bio-compatibility. However, recently, there are concerns over the wear behaviour of metal-on-metal artificial hip joints and the formation of numerous nano-sized wear debris from the articulating Co-Cr surfaces. This is mainly because such extremely fine wear debris could release chromium and cobalt ions into the host body, which can cause potential toxicity. Therefore, how to improve the wear resistance of Co-Cr alloys is a scientifically interesting and clinically important research topic. This study aimed to improve the hardness, wear, corrosion and corrosion-wear properties of medical grade Co-Cr by plasma surface alloying with nitrogen and with both nitrogen and carbon at very low temperatures (between 300 and 400 degrees C). The metallurgy, mechanical, chemical and wear properties of the surface alloyed layers were characterised and the results demonstrate that the optimised treatment conditions have produced very promising surface layers on Co-Cr alloy for biomedical applications. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:906 / 911
页数:6
相关论文
共 50 条
  • [1] Surface modification of Co-Cr-Mo alloy by plasma assisted CVD
    Resen, Ali Mezher
    MATERIALS TODAY-PROCEEDINGS, 2021, 42 : 2896 - 2900
  • [2] Biochemical surface modification of Co-Cr-Mo
    Puleo, DA
    BIOMATERIALS, 1996, 17 (02) : 217 - 222
  • [3] Low temperature plasma surface alloying of medical grade austenitic stainless steel with carbon and nitrogen
    Buhagiar, J.
    Dong, H.
    Bell, T.
    SURFACE ENGINEERING, 2007, 23 (04) : 313 - 317
  • [4] Low temperature plasma surface alloying of medical grade austenitic stainless steel with carbon and nitrogen
    Buhagiar, J.
    Dong, H.
    Bell, T.
    BHM Berg- und Huttenmannische Monatshefte, 2006, 151 (11): : 446 - 450
  • [5] Surface modification of Co-Cr-Mo implant alloy by laser interference lithography
    Wei, Xiaofeng
    Li, Wenjun
    Liang, Bojian
    Li, Binglin
    Zhang, Jinjin
    Zhang, Linshuai
    Wang, Zuobin
    TRIBOLOGY INTERNATIONAL, 2016, 97 : 212 - 217
  • [6] Investigation of laser surface texturing parameters of biomedical grade Co-Cr-Mo alloy
    Kasman, Sefika
    Ucar, Ibrahim Can
    Ozan, Sertan
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2023, 125 (9-10): : 4271 - 4291
  • [7] Investigation of laser surface texturing parameters of biomedical grade Co-Cr-Mo alloy
    Şefika Kasman
    İbrahim Can Uçar
    Sertan Ozan
    The International Journal of Advanced Manufacturing Technology, 2023, 125 : 4271 - 4291
  • [8] Nitriding of Co-Cr-Mo alloy in nitrogen
    Tang, Ning
    Li, Yunping
    Koizumi, Yuichiro
    Chiba, Akihiko
    MATERIALS CHEMISTRY AND PHYSICS, 2014, 145 (03) : 350 - 356
  • [9] High temperature passive film on the surface of Co-Cr-Mo alloy and its tribological properties
    Guo, Feifei
    Dong, Guangneng
    Dong, Lishe
    APPLIED SURFACE SCIENCE, 2014, 314 : 777 - 785
  • [10] Surface modification of carbon fiber by fluoropolymer in a low-temperature plasma
    Shelestova V.A.
    Zhandarov S.F.
    Danchenko S.G.
    Grakovich P.N.
    Inorganic Materials: Applied Research, 2015, 6 (03) : 219 - 224